ترغب بنشر مسار تعليمي؟ اضغط هنا

A Tungsten / Scintillating Fiber Electromagnetic Calorimeter Prototype for a High-Rate Muon g-2 Experiment

131   0   0.0 ( 0 )
 نشر من قبل Kevin Lynch
 تاريخ النشر 2009
  مجال البحث فيزياء
والبحث باللغة English
 تأليف R. McNabb




اسأل ChatGPT حول البحث

A compact and fast electromagnetic calorimeter prototype was designed, built, and tested in preparation for a next-generation, high-rate muon g-2 experiment. It uses a simple assembly procedure: alternating layers of 0.5-mm-thick tungsten plates and 0.5-mm-diameter plastic scintillating fiber ribbons. This geometry leads to a detector having a calculated radiation length of 0.69 cm, a Moliere radius of 1.73 cm, and a measured intrinsic sampling resolution term of (11.8pm1.1)/sqrt{E(GeV)}, in the range 1.5 to 3.5 GeV. The construction procedure, test beam results, and GEANT-4 comparative simulations are described.



قيم البحث

اقرأ أيضاً

A new method called Neighbor Cell Deposited Energy Ratio (NCDER) is proposed to reconstruct incidence position in a single layer for a 3-dimensional imaging electromagnetic calorimeter (ECAL).This method was applied to reconstruct the ECAL test beam data for the Alpha Magnetic Spectrometer-02 (AMS-02). The results show that this method can achieve an angular resolution of 7.36pm 0.08 / sqrt(E) oplus 0.28 pm 0.02 degree in the determination of the photons direction, which is much more precise than that obtained with the commonly-adopted Center of Gravity(COG) method (8.4 pm 0.1 /sqrt(E) oplus 0.8pm0.3 degree). Furthermore, since it uses only the properties of electromagnetic showers, this new method could also be used for other type of fine grain sampling calorimeters.
New generation high-energy physics experiments demand high precision tracking and accurate measurements of a large number of particles produced in the collisions of lementary particles and heavy-ions. Silicon-tungsten (Si-W) calorimeters provide the most viable technological option to meet the requirements of particle detection in high multiplicity environments. We report a novel Si-W calorimeter design, which is optimized for $gamma/pi^0$ discrimination up to high momenta. In order to test the feasibility of the calorimeter, a prototype mini-tower was constructed using silicon pad detector arrays and tungsten layers. The performance of the mini-tower was tested using pion and electron beams at the CERN Proton Synchrotron (PS). The experimental results are compared with the results from a detailed GEANT-4 simulation. A linear relationship between the observed energy deposition and simulated response of the mini-tower has been obtained, in line with our expectations.
The long slab is a new prototype for the SiW-Ecal, a silicon tungsten electromagnetic calorimeter for the ILD detector of the future International Linear Collider. This new prototype has been designed to demonstrate the ability to build a full length detecting layer (1.60m for the ILD barrel). Indeed, this length induces difficulties for clock and signal propagation and data integrity. The design used for short length slabs had to be adapted on the basis of a simulation study. The long slab performance has been tested with cosmics, radioactive source and with 3 GeV electrons in the beam tests at DESY, Hamburg. The results of the per-channel calibration of the detector are presented. In DESY beam tests we have accumulated data for both normal and inclined incidence of the beam. With the latter one particle can sometimes traverse two pixels and deposit less energy per pixel. We show how this can be used to measure the position of the trigger threshold. This new prototype gives us a lot of hints on how to improve the design of the front-end electronics. It is also a convenient tool to estimate the key characteristics of ILD SiW-Ecal (like power consumption, cooling, readout time etc.) and to optimize the future design of the detector.
209 - H. Gast , R. Greim , T. Kirn 2007
Using thin scintillating fibers with Silicon Photomultiplier (SiPM) readout a mo dular high-resolution charged-particle tracking detector has been designed. The fiber modules consist of 2 x 5 layers of 128 round multiclad scintillating fiber s of 0.2 50mm diameter. The fibers are read out by four SiPM arrays (8mm x 1mm) e ach on either end of the module.
126 - Frederick Gray 2015
A new experiment at Fermilab will measure the anomalous magnetic moment of the muon with a precision of 140 parts per billion (ppb). This measurement is motivated by the results of the Brookhaven E821 experiment that were first released more than a d ecade ago, which reached a precision of 540 ppb. As the corresponding Standard Model predictions have been refined, the experimental and theoretical values have persistently differed by about 3 standard deviations. If the Brookhaven result is confirmed at Fermilab with this improved precision, it will constitute definitive evidence for physics beyond the Standard Model. The experiment observes the muon spin precession frequency in flight in a well-calibrated magnetic field; the improvement in precision will require both 20 times as many recorded muon decay events as in E821 and a reduction by a factor of 3 in the systematic uncertainties. This paper describes the current experimental status as well as the plans for the upgraded magnet, detector and storage ring systems that are being prepared for the start of beam data collection in 2017.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا