ترغب بنشر مسار تعليمي؟ اضغط هنا

RXTE Monitoring of the Anomalous X-ray Pulsar 1E 1048.1-5937: Long-Term Variability and the 2007 March Event

268   0   0.0 ( 0 )
 نشر من قبل Rim Dib
 تاريخ النشر 2009
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

After three years of no unusual activity, Anomalous X-ray Pulsar 1E 1048.1-5937 reactivated in 2007 March. We report on the detection of a large glitch (Delta(nu)/nu =1.63(2)X~10^{-5}) on 2007 March 26 (MJD 54185.9), contemporaneous with the onset of a pulsed-flux flare, the third flare observed from this source in 10 years of monitoring with the Rossi X-ray Timing Explorer. Additionally, we report on a detailed study of the evolution of the timing properties, the pulsed flux, and the pulse profile of this source as measured by RXTE from 1996 July to 2008 January. In our timing study, we attempted phase coherent timing of all available observations. We show that in 2001, a timing anomaly of uncertain nature occurred near the rise of the first pulsed flux flare; we show that a likely glitch (Delta(nu)/nu =2.91(9)X10^{-6}) occurred in 2002, near the rise of the second flare, and we present a detailed description of the variations in the spin-down. In our pulsed flux study, we compare the decays of the three flares and discuss changes in the hardness ratio. In our pulse profile study, we show that the profile exhibited large variations near the peak of the first two flares, and several small short-term profile variations during the most recent flare. Finally, we report on the discovery of a small burst 27 days after the peak of the last flare, the fourth burst discovered from this source. We discuss the relationships between the observed properties in the framework of the magnetar model.



قيم البحث

اقرأ أيضاً

292 - Z. Wang , C. Bassa , V. M. Kaspi 2008
We report on optical and infrared observations of the anomalous X-ray pulsar (AXP) 1E 1048.1-5937, made during its ongoing X-ray flare which started in 2007 March. We detected the source in the optical I and near-infrared Ks bands in two ground-based observations and obtained deep flux upper limits from four observations, including one with the Spitzer Space Telescope at 4.5 and 8.0 microns. The detections indicate that the source was approximately 1.3--1.6 magnitudes brighter than in 2003--2006, when it was at the tail of a previous similar X-ray flare. Similar related flux variations have been seen in two other AXPs during their X-ray outbursts, suggesting common behavior for large X-ray flux variation events in AXPs. The Spitzer flux 1E 1048.1-5937 limits are sufficiently deep that we can exclude mid-infrared emission similar to that from the AXP 4U 0142+61, which has been interpreted as arising from a dust disk around the AXP. The optical/near-infrared emission from probably has a magnetospheric origin. The similarity in the flux spectra of 4U 0142+61 and 1E 1048.1-5937 challenges the dust disk model proposed for the latter.
105 - Zhongxiang Wang 2002
We report our discovery of the likely near-infrared counterpart to the anomalous X-ray pulsar (AXP) 1E1048.1-5937, using observations from the 6.5-m Baade (Magellan-I) telescope in Chile. We derived a precise position for the X-ray source using archi val data from the Chandra X-Ray Observatory. This position is inconsistent with a position reported earlier from XMM-Newton, but we show that the originally reported XMM-Newton position suffered from attitude reconstruction problems. Only two of the infrared objects in a 17 arcsec x 17 arcsec field containing the target have unusual colors, and one of these has colors consistent with those of the identified counterparts of two other AXPs. The latter object is also the only source detected within the 0.6 arcsec Chandra error circle, and we identify it as the counterpart to 1E1048.1-5937. This is the first AXP counterpart detected in multiple infrared bands, with magnitudes J=21.7(3), H=20.8(3), and K=19.4(3). There is marginal evidence for spectral flattening at longer wavelengths.
135 - Cindy R. Tam 2007
(Abridged) We report on new and archival X-ray and near-infrared observations of the anomalous X-ray pulsar 1E 1048.1-5937 performed between 2001-2007 with RXTE, CXO, Swift, HST, and VLT. During its ~2001-2004 active period, 1E 1048.-5937 exhibited t wo large, long-term X-ray pulsed-flux flares as well as short bursts, and large (>10x) torque changes. Monitoring with RXTE revealed that the source entered a phase of timing stability in 2004; at the same time, a series of four simultaneous observations with CXO and HST in 2006 showed that its X-ray flux and spectrum and near-IR flux, all variable prior to 2005, stabilized. The near-IR flux, when detected by HST (H~22.7 mag) and VLT (K_S~21.0 mag), was considerably fainter than previously measured. Recently, in 2007 March, this newfound quiescence was interrupted by a sudden flux enhancement, X-ray spectral changes and a pulse morphology change, simultaneous with a large spin-up glitch and near-IR enhancement. Our RXTE observations revealed a sudden pulsed flux increase by a factor of ~3 in the 2-10 keV band. In observations with CXO and Swift, we found that the total X-ray flux increased much more than the pulsed flux, reaching a peak value of >7 times the quiescent value (2-10 keV). With these recent data, we find a strong anti-correlation between X-ray flux and pulsed fraction, and a correlation between X-ray spectral hardness and flux. Simultaneously with the radiative and timing changes, we observed a significant X-ray pulse morphology change such that the profile went from nearly sinusoidal to having multiple peaks. We compare these remarkable events with other AXP outbursts and discuss implications in the context of the magnetar model and other models of AXP emission.
We report on 10 years of monitoring of the 8.7-s Anomalous X-ray Pulsar 4U 0142+61 using the Rossi X-Ray Timing Explorer (RXTE). This pulsar exhibited stable rotation from 2000 March until 2006 February: the RMS phase residual for a spin-down model w hich includes nu, nudot, and nuddot is 2.3%. We report a possible phase-coherent timing solution valid over a 10-yr span extending back to March 1996. A glitch may have occured between 1998 and 2000, but is not required by the existing timing data. The pulse profile has been evolving since 2000. In particular, the dip of emission between its two peaks got shallower between 2002 and 2006, as if the profile were evolving back to its pre-2000 morphology, following an earlier event, which possibly also included the glitch suggested by the timing data. These profile variations are seen in the 2-4 keV band but not in 6-8 keV. We also detect a slow increase in the pulsed flux between 2002 May and 2004 December, such that it has risen by 36+/-3% over 2.6 years in the 2-10 keV band. The pulsed flux variability and the narrow-band pulse profile changes present interesting challenges to aspects of the magnetar model.
We report on 10 yr of monitoring of the 8.7-s Anomalous X-ray Pulsar 4U 0142+61 using the Rossi X-Ray Timing Explorer (RXTE). This pulsar exhibited stable rotation from 2000 until February 2006: the RMS phase residual for a spin-down model which incl udes nu, nudot, and nuddot is 2.3%. We report a possible phase-coherent timing solution valid over a 10-yr span extending back to March 1996. A glitch may have occured between 1998 and 2000, but it is not required by the existing data. We also report that the sources pulse profile has been evolving in the past 6 years, such that the dip of emission between its two peaks has been getting shallower since 2000, almost as if the profile is recovering to its pre-2000 morphology, in which there was no clear distinction between the peaks. These profile variations are seen in the 2-4 keV band but not in 6-8 keV. Finally, we present the pulsed flux time series of the source in 2-10 keV. There is evidence of a slow but steady increase in the sources pulsed flux since 2000. The pulsed flux variability and the narrow-band pulse profile changes present interesting challenges to aspects of the magnetar model.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا