We present a non-iterative method to deconvolve the spatial response function or the point spread function (PSF) from images taken with the Suzaku X-ray Imaging Spectrometer (XIS). The method is optimized for analyses of extended sources with high photon statistics. Suzaku has four XIS detectors each with its own X-ray CCD and X-Ray Telescope (XRT) and has been providing unique opportunities in spatially-resolved spectroscopic analyses of extended objects. The detectors, however, suffer from broad and position-dependent PSFs with their typical half-power density (HPD) of about 110. In the authors view, this shortcoming has been preventing the high collecting area and high spectral resolution of Suzaku to be fully exploited. The present method is intended to recover spatial resolution to ~15 over a dynamic range around 1:100 in the brightness without assuming any source model. Our deconvolution proceeds in two steps: An XIS image is multiplied with the inverse response matrix calculated from its PSF after rebinning CCD pixels to larger-size tiles (typically 6x 6); The inverted image is then adaptively smoothed to obtain the final deconvolved image. The PSF is modeled on a ray-tracing program and an observed point-source image. The deconvolution method has been applied to images of Centaurus A, PSR B1509-58 and RCW 89 taken by one XIS (XIS-1). The results have been compared with images obtained with Chandra to conclude that the spatial resolution has been recovered to ~20 down to regions where surface brightness is about 1:50 of the brightest tile in the image. We believe the spatial resolution and the dynamic range can be improved in the future with higher fidelity PSF modeling and higher precision pointing information.

قيم البحث

اقرأ أيضاً

The charge transfer inefficiency (CTI) of the X-ray CCDs on board the Suzaku satellite (X-ray Imaging Spectrometers; XIS) has increased since the launch due to radiation damage, and the energy resolution has been degraded. To improve the CTI, we have applied a spaced-row charge injection (SCI) technique to the XIS in orbit; by injecting charges into CCD rows periodically, the CTI is actively decreased. The CTI in the SCI mode depends on the distance between a signal charge and a preceding injected row, and the pulse height shows periodic positional variations. Using in-flight data of onboard calibration sources and of the strong iron line from the Perseus cluster of galaxies, we studied the variation in detail. We developed a new method to correct the variation. By applying the new method, the energy resolution (FWHM) at 5.9 keV at March 2008 is ~155 eV for the front-illuminated CCDs and ~175 eV for the back-illuminated CCD.
The X-ray Imaging Spectrometer (XIS) on board the Suzaku satellite is an X-ray CCD camera system that has superior performance such as a low background, high quantum efficiency, and good energy resolution in the 0.2-12 keV band. Because of the radiat ion damage in orbit, however, the charge transfer inefficiency (CTI) has increased, and hence the energy scale and resolution of the XIS has been degraded since the launch of July 2005. The CCD has a charge injection structure, and the CTI of each column and the pulse-height dependence of the CTI are precisely measured by a checker flag charge injection (CFCI) technique. Our precise CTI correction improved the energy resolution from 230 eV to 190 eV at 5.9 keV in December 2006. This paper reports the CTI measurements with the CFCI experiments in orbit. Using the CFCI results, we have implemented the time-dependent energy scale and resolution to the Suzaku calibration database.
74 - Y. Maeda , Y. Uchiyama , A. Bamba 2009
Suzaku X-ray observations of a young supernova remnant, Cassiopeia A, were carried out. K-shell transition lines from highly ionized ions of various elements were detected, including Chromium (Cr-Kalpha at 5.61 keV). The X-ray continuum spectra were modeled in the 3.4--40 keV band, summed over the entire remnant, and were fitted with a simplest combination of the thermal bremsstrahlung and the non-thermal cut-off power-law models. The spectral fits with this assumption indicate that the continuum emission is likely to be dominated by the non-thermal emission with a cut-off energy at > 1 keV. The thermal-to-nonthermal fraction of the continuum flux in the 4-10 keV band is best estimated as ~0.1. Non-thermal-dominated continuum images in the 4--14 keV band were made. The peak of the non-thermal X-rays appears at the western part. The peak position of the TeV gamma-rays measured with HEGRA and MAGIC is also shifted at the western part with the 1-sigma confidence. Since the location of the X-ray continuum emission was known to be presumably identified with the reverse shock region, the possible keV-TeV correlations give a hint that the accelerated multi-TeV hadrons in Cassiopeia A are dominated by heavy elements in the reverse shock region.
176 - K. Koyama , Y. Hyodo , T. Inui 2007
We report on the diffuse X-ray emissions from the Galactic center (GCDX) observed with the X-ray Imaging Spectrometer (XIS) on board the Suzaku satellite. The highly accurate energy calibrations and extremely low background of the XIS provide many ne w facts on the GCDX. These are (1) the origin of the 6.7/7.0keV lines is collisional excitation in hot plasma, (2) new SNR and super-bubble candidates are found, (3) most of the 6.4keV line is fluorescence by X-rays, and (4) time variability of the 6.4keV line is found from the SgrB2 complex.
We present a detailed analysis of the X-ray emission from the middle-aged supernova remnant W51C and star-forming region W51B with Suzaku. The soft X-ray emission from W51C is well represented by an optically thin thermal plasma in the non-equilibriu m ionization state with a temperature of $sim$0.7 keV. The elemental abundance of Mg is significantly higher than the solar value. We find no significant feature of an over-ionized plasma in W51C. The hard X-ray emission is spatially coincident with the molecular clouds associated with W51B, overlapping with W51C. The spectrum is represented by an optically thin thermal plasma with a temperature of $sim$5 keV or a powerlaw model with a photon index of $sim$2.2. The emission probably has diffuse nature since its luminosity of 1$times10^{34}$ erg s$^{-1}$ in the 0.5-10 keV band cannot be explained by the emission from point sources in this region. We discuss the possibility that the hard X-ray emission comes from stellar winds of OB stars in W51B or accelerated particles in W51C.