ترغب بنشر مسار تعليمي؟ اضغط هنا

Effect of a Physical Phase Plate on Contrast Transfer in an Aberration-Corrected Transmission Electron Microscope

124   0   0.0 ( 0 )
 نشر من قبل Bjoern Gamm
 تاريخ النشر 2010
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

In this theoretical study we analyze contrast transfer of weak-phase objects in a transmission electron microscope, which is equipped with an aberration corrector (Cs-corrector) in the imaging lens system and a physical phase plate in the back focal plane of the objective lens. For a phase shift of pi/2 between scattered and unscattered electrons induced by a physical phase plate, the sine-type phase contrast transfer function is converted into a cosine-type function. Optimal imaging conditions could theoretically be achieved if the phase shifts caused by the objective lens defocus and lens aberrations would be equal zero. In reality this situation is difficult to realize because of residual aberrations and varying, non-zero local defocus values, which in general result from an uneven sample surface topography. We explore the conditions - i.e. range of Cs-values and defocus - for most favourable contrast transfer as a function of the information limit, which is only limited by the effect of partial coherence of the electron wave in Cs-corrected transmission electron microscopes. Under high-resolution operation conditions we find that a physical phase plate improves strongly low- and medium-resolution object contrast, while improving tolerance to defocus and Cs-variations, compared to a microscope without a phase plate.



قيم البحث

اقرأ أيضاً

In this work, an optic fiber based $textit{in situ}$ illumination system integrated into an aberration-corrected environmental transmission electron microscope (ETEM) is designed, built, characterized and applied. With this illumination system, the d ynamic responses of photoactive materials to photons can be directly observed at the atomic level, and other stimuli including heating and various gases can also be applied simultaneously. Either a broadband light source or a high power laser source aiming to expedite photoreactions can be utilized, fitting different application needs. The optic fiber enters the ETEM through the objective aperture port, with a carefully designed curvature and a 30{deg} cut at the tip to orient the emitted light upwards onto the TEM specimen. The intensity distributions striking the sample from the broadband and laser sources are both measured, and due to the non-uniform distributions, an alignment procedure has been developed to align the bright spot with the electron optical axis of the TEM. The imaging and spectroscopy performances of the ETEM are proved to be maintained after incorporating this illumination system. Furthermore, Langmuir evaporation is observed when in situ laser light is applied to GaAs, demonstrating the phenomenon of optical heating on suitable semiconductor materials.
751 - Binghui Ge , Yumei Wang , Yuan Yao 2012
For quantitative electron microscopy high precision position information is necessary so that besides an adequate resolution and sufficiently strong contrast of atoms, small width of peaks which represent atoms in structural images is needed. Size of peak is determined by point spread (PS) of instruments as well as that of atoms when point resolution reach the subangstrom scale and thus PS of instruments is comparable with that of atoms. In this article, relationship between PS with atomic numbers, sample thickness, and spherical aberration coefficients will be studied in both negative Cs imaging (NCSI) and positive Cs imaging (PCSI) modes by means of dynamical image simulation. Through comparing the peak width with different thickness and different values of spherical aberration, NCSI mode is found to be superior to PCSI considering smaller peak width in the structural image.
Incommensurate modulated structure (IMS) in Bi2Sr1.6La0.4CuO6+{delta} (BSLCO) has been studied by aberration corrected transmission electron microscopy in combination with high-dimensional (HD) space description. Two images in the negative Cs imaging (NCSI) and passive Cs imaging (PCSI) modes were deconvoluted, respectively. Similar results as to IMS have been obtained from two corresponding projected potential maps (PPMs), but meanwhile the size of dots representing atoms in the NCSI PPM is found to be smaller than that in PCSI one. Considering that size is one of influencing factors of precision, modulation functions for all unoverlapped atoms in BSLCO were determined based on the PPM obtained from the NCSI image in combination with HD space description.
Ultra-fast transmission electron microscopy (UTEM) combines sub-picosecond time-resolution with the versatility of TEM spectroscopies. It allows one to study the dynamics of materials properties combining complementary techniques. However, until now, time-resolved cathodoluminescence, which is expected to give access to the optical properties dynamics, was still unavailable in a UTEM. In this paper, we report time-resolved cathodoluminescence measurements in an ultrafast transmission electron microscope. We measured lifetime maps, with a 12 nm spatial resolution and sub-nanoseconds resolution, of nano-diamonds with a high density of NV center. This study paves the way to new applications of UTEM and to correlative studies of optically active nanostructures.
354 - B.Gamm , M. Dries , K. Schultheiss 2010
A method is described for the reconstruction of the amplitude and phase of the object exit wave function by phase-plate transmission electron microscopy. The proposed method can be considered as in-line holography and requires three images, taken wit h different phase shifts between undiffracted and diffracted electrons induced by a suitable phase-shifting device. The proposed method is applicable for arbitrary object exit wave functions and non-linear image formation. Verification of the method is performed for examples of a simulated crystalline object wave function and a wave function acquired with off-axis holography. The impact of noise on the reconstruction of the wave function is investigated.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا