ترغب بنشر مسار تعليمي؟ اضغط هنا

Determination of incommensurate modulated structure in Bi2Sr1.6La0.4CuO6+{delta} by aberration-corrected transmission electron microscopy

391   0   0.0 ( 0 )
 نشر من قبل Binghui Ge
 تاريخ النشر 2012
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Incommensurate modulated structure (IMS) in Bi2Sr1.6La0.4CuO6+{delta} (BSLCO) has been studied by aberration corrected transmission electron microscopy in combination with high-dimensional (HD) space description. Two images in the negative Cs imaging (NCSI) and passive Cs imaging (PCSI) modes were deconvoluted, respectively. Similar results as to IMS have been obtained from two corresponding projected potential maps (PPMs), but meanwhile the size of dots representing atoms in the NCSI PPM is found to be smaller than that in PCSI one. Considering that size is one of influencing factors of precision, modulation functions for all unoverlapped atoms in BSLCO were determined based on the PPM obtained from the NCSI image in combination with HD space description.



قيم البحث

اقرأ أيضاً

751 - Binghui Ge , Yumei Wang , Yuan Yao 2012
For quantitative electron microscopy high precision position information is necessary so that besides an adequate resolution and sufficiently strong contrast of atoms, small width of peaks which represent atoms in structural images is needed. Size of peak is determined by point spread (PS) of instruments as well as that of atoms when point resolution reach the subangstrom scale and thus PS of instruments is comparable with that of atoms. In this article, relationship between PS with atomic numbers, sample thickness, and spherical aberration coefficients will be studied in both negative Cs imaging (NCSI) and positive Cs imaging (PCSI) modes by means of dynamical image simulation. Through comparing the peak width with different thickness and different values of spherical aberration, NCSI mode is found to be superior to PCSI considering smaller peak width in the structural image.
120 - Pratibha Gai , Edward Boyes 2017
Advances in atomic resolution in situ environmental transmission electron microscopy for direct probing of gas-solid reactions, including at very high temperatures are described. In addition, recent developments of dynamic real time in situ studies a t the Angstrom level using a hot stage in an aberration corrected environment are presented. In situ data from Pt and Pd nanoparticles on carbon with the corresponding FFT (optical diffractogram) illustrate an achieved resolution of 0.11 nm at 500 C and higher in a double aberration corrected TEM and STEM instrument employing a wider gap objective pole piece. The new results open up opportunities for dynamic studies of materials in an aberration corrected environment.
In this work, an optic fiber based $textit{in situ}$ illumination system integrated into an aberration-corrected environmental transmission electron microscope (ETEM) is designed, built, characterized and applied. With this illumination system, the d ynamic responses of photoactive materials to photons can be directly observed at the atomic level, and other stimuli including heating and various gases can also be applied simultaneously. Either a broadband light source or a high power laser source aiming to expedite photoreactions can be utilized, fitting different application needs. The optic fiber enters the ETEM through the objective aperture port, with a carefully designed curvature and a 30{deg} cut at the tip to orient the emitted light upwards onto the TEM specimen. The intensity distributions striking the sample from the broadband and laser sources are both measured, and due to the non-uniform distributions, an alignment procedure has been developed to align the bright spot with the electron optical axis of the TEM. The imaging and spectroscopy performances of the ETEM are proved to be maintained after incorporating this illumination system. Furthermore, Langmuir evaporation is observed when in situ laser light is applied to GaAs, demonstrating the phenomenon of optical heating on suitable semiconductor materials.
In this theoretical study we analyze contrast transfer of weak-phase objects in a transmission electron microscope, which is equipped with an aberration corrector (Cs-corrector) in the imaging lens system and a physical phase plate in the back focal plane of the objective lens. For a phase shift of pi/2 between scattered and unscattered electrons induced by a physical phase plate, the sine-type phase contrast transfer function is converted into a cosine-type function. Optimal imaging conditions could theoretically be achieved if the phase shifts caused by the objective lens defocus and lens aberrations would be equal zero. In reality this situation is difficult to realize because of residual aberrations and varying, non-zero local defocus values, which in general result from an uneven sample surface topography. We explore the conditions - i.e. range of Cs-values and defocus - for most favourable contrast transfer as a function of the information limit, which is only limited by the effect of partial coherence of the electron wave in Cs-corrected transmission electron microscopes. Under high-resolution operation conditions we find that a physical phase plate improves strongly low- and medium-resolution object contrast, while improving tolerance to defocus and Cs-variations, compared to a microscope without a phase plate.
Aberration-corrected electron microscopy can resolve the smallest atomic bond-lengths in nature. However, the high-convergence angles that enable spectacular resolution in 2D have unknown 3D resolution limits for all but the smallest objects ($< sim$ 8nm). We show aberration-corrected electron tomography offers new limits for 3D imaging by measuring several focal planes at each specimen tilt. We present a theoretical foundation for aberration-corrected electron tomography by establishing analytic descriptions for resolution, sampling, object size, and dose---with direct analogy to the Crowther-Klug criterion. Remarkably, aberration-corrected scanning transmission electron tomography can measure complete 3D specimen structure of unbounded object sizes up to a specified cutoff resolution. This breaks the established Crowther limit when tilt increments are twice the convergence angle or smaller. Unprecedented 3D resolution is achievable across large objects. Atomic 3D imaging (1$unicode{xC5}$) is allowed across extended objects larger than depth-of-focus (e.g. $>$ 20nm) using available microscopes and modest specimen tilting ($<$ 3$^circ$). Furthermore, aberration-corrected tomography follows the rule of dose-fractionation where a specified total dose can be divided among tilts and defoci.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا