ترغب بنشر مسار تعليمي؟ اضغط هنا

Precision Measurement of a low-loss Cylindrical Dumbbell-Shaped Sapphire Mechanical Oscillator using Radiation Pressure

118   0   0.0 ( 0 )
 نشر من قبل Jeremy Bourhill
 تاريخ النشر 2015
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We present first results from a number of experiments conducted on a 0.53 kg cylindrical dumbbell-shaped sapphire crystal. This is the first reported optomechanical experiment of this nature utilising a novel modification to the typical cylindrical architecture. Mechanical motion of the crystal structure alters the dimensions of the crystal, and the induced strain changes the permittivity. These two effects result in parametric frequency modulation of resonant microwave whispering gallery modes that are simultaneously excited within the crystal. A novel low-noise microwave readout system is implemented allowing extremely low noise measurements of this frequency modulation near our modes of interest, having a phase noise floor of -165 dBc/Hz at 100 kHz. Fine-tuning of the crystals suspension has allowed for the optimisation of mechanical quality factors in preparation for cryogenic experiments, with a value of Q=8 x 10^7 achieved at 127 kHz. This results in a Q x f product of 10^13, equivalent to the best measured values in a macroscopic sapphire mechanical system. Results are presented that demonstrate the excitation of mechanical modes via radiation pressure force, allowing an experimental method of determining the transducers displacement sensitivity df/dx, and calibrating the system. Finally, we demonstrate parametric back-action phenomenon within the system. These are all important steps towards the overall goal of the experiment; to cool a macroscopic device to the quantum ground state at millikelvin temperatures.



قيم البحث

اقرأ أيضاً

A Cryogenic Sapphire Oscillator has been implemented at 11.2 GHz using a low-vibration design pulse-tube cryocooler. Compared with a state-of-the-art liquid helium cooled CSO in the same laboratory, the square root Allan variance of their combined fr actional frequency instability is $sigma_y = 1.4 times 10^{-15}tau^{-1/2}$ for integration times $1 < tau < 10$ s, dominated by white frequency noise. The minimum $sigma_y = 5.3 times 10^{-16}$ for the two oscillators was reached at $tau = 20$ s. Assuming equal contributions from both CSOs, the single oscillator phase noise $S_{phi} approx -96 ; dB ; rad^2/Hz$ at 1 Hz offset from the carrier.
Here we present the design and implementation of a novel frequency synthesizer based on low phase noise digital dividers and a direct digital synthesizer. The synthesis produces two low noise accurate and tunable signals at 10 MHz and 100 MHz. We rep ort on the measured residual phase noise and frequency stability of the synthesizer, and estimate the total frequency stability, which can be expected from the synthesizer seeded with a signal near 11.2 GHz from an ultra-stable cryocooled sapphire oscillator. The synthesizer residual single sideband phase noise, at 1 Hz offset, on 10 MHz and 100 MHz signals, respectively, were measured to be -135 dBc/Hz and -130 dBc/Hz. Their intrinsic frequency stability contributions, on the 10 MHz and 100 MHz signals, respectively, were measured as sigma_y = 9 x 10^-15 and sigma_y = 2.2 x 10^-15, at 1 s integration time. The Allan Deviation of the total fractional frequency noise on the 10 MHz and 100 MHz signals derived from the synthesizer with the cryocooled sapphire oscillator, may be estimated as sigma_y = 5.2 x 10^-15 tau ^-1 + 3.6 x 10^-15 tau ^-1/2 + 4 x 10^-16 and sigma_y = 2 x 10^-15 tau ^-1/2 + 3 x 10^-16, respectively, for 1 s < tau < 10^4 s. We also calculate the coherence function, (a figure of merit in VLBI) for observation frequencies of 100 GHz, 230 GHz and 345 GHz, when using the cryocooled sapphire oscillator and an hydrogen maser. The results show that the cryocooled sapphire oscillator offers a significant advantage at frequencies above 100 GHz.
Cooling of a 58 MHz micro-mechanical resonator from room temperature to 11 K is demonstrated using cavity enhanced radiation pressure. Detuned pumping of an optical resonance allows enhancement of the blue shifted motional sideband (caused by the osc illators Brownian motion) with respect to the red-shifted sideband leading to cooling of the mechanical oscillator mode. The reported cooling mechanism is a manifestation of the effect of radiation pressure induced dynamical backaction. These results constitute an important step towards achieving ground state cooling of a mechanical oscillator.
113 - P. Klag , P. Achenbach , M. Biroth 2018
A novel interferometric method for absolute beam energy measurement is under development at MAMI. At the moment, the method is tested and optimized at an energy of 195 MeV. Despite the very small statistical uncertainty of the method, systematic effe cts have limited the overall accuracy. Recently, a measurement has been performed dedicated to the evaluation of these effects. This report comprises a description of the method and results of the recent data taking period.
We have developed a mechanical absolute-rotation sensor capable of resolving ground rotation angle of less than 1 nrad$/sqrt{text{Hz}}$ above $30$ mHz and 0.2 nrad$/sqrt{text{Hz}}$ above $100$ mHz about a single horizontal axis. The device consists o f a meter-scale beam balance, suspended by a pair of flexures, with a resonance frequency of 10.8 mHz. The center of mass is located 3 $mu$m above the pivot, giving an excellent horizontal displacement rejection of better than $3times10^{-5}$ rad/m. The angle of the beam is read out optically using a high-sensitivity autocollimator. We have also built a tiltmeter with better than 1 nrad$/sqrt{text{Hz}}$ sensitivity above 30 mHz. Co-located measurements using the two instruments allowed us to distinguish between background rotation signal at low frequencies and intrinsic instrument noise. The rotation sensor is useful for rotational seismology and for rejecting background rotation signal from seismometers in experiments demanding high levels of seismic isolation, such as Advanced LIGO.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا