ترغب بنشر مسار تعليمي؟ اضغط هنا

Precision beam energy measurement by undulator radiation at MAMI

114   0   0.0 ( 0 )
 نشر من قبل Patrick Achenbach
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

A novel interferometric method for absolute beam energy measurement is under development at MAMI. At the moment, the method is tested and optimized at an energy of 195 MeV. Despite the very small statistical uncertainty of the method, systematic effects have limited the overall accuracy. Recently, a measurement has been performed dedicated to the evaluation of these effects. This report comprises a description of the method and results of the recent data taking period.



قيم البحث

اقرأ أيضاً

85 - Ihar Lobach 2020
Generally, turn-to-turn power fluctuations of incoherent spontaneous synchrotron radiation in a storage ring depend on the 6D phase-space distribution of the electron bunch. In some cases, if only one parameter of the distribution is unknown, this pa rameter can be determined from the measured magnitude of these power fluctuations. In this Letter, we report an absolute measurement (no free parameters or calibration) of a small vertical emittance (5--15 nm rms) of a flat beam by this method, under conditions, when it is unresolvable by a conventional synchrotron light beam size monitor.
We describe the construction and operation of an x-ray beam size monitor (xBSM), a device measuring $e^+$ and $e^-$ beam sizes in the CESR-TA storage ring using synchrotron radiation. The device can measure vertical beam sizes of $10-100~mu$m on a tu rn-by-turn, bunch-by-bunch basis at $e^pm$ beam energies of $sim2~$GeV. At such beam energies the xBSM images x-rays of $epsilonapprox$1-10$~$keV ($lambdaapprox 0.1-1$ nm) that emerge from a hard-bend magnet through a single- or multiple-slit (coded aperture) optical element onto an array of 32 InGaAs photodiodes with 50$~mu$m pitch. Beamlines and detectors are entirely in-vacuum, enabling single-shot beam size measurement down to below 0.1$~$mA ($2.5times10^9$ particles) per bunch and inter-bunch spacing of as little as 4$~$ns. At $E_{rm b}=2.1 $GeV, systematic precision of $sim 1~mu$m is achieved for a beam size of $sim12~mu$m; this is expected to scale as $propto 1/sigma_{rm b}$ and $propto 1/E_{rm b}$. Achieving this precision requires comprehensive alignment and calibration of the detector, optical elements, and x-ray beam. Data from the xBSM have been used to extract characteristics of beam oscillations on long and short timescales, and to make detailed studies of low-emittance tuning, intra-beam scattering, electron cloud effects, and multi-bunch instabilities.
We propose a new method for absolute momentum calibration of magnetic spectrometers used in nuclear physics, using the time-of-flight (TOF), differences of pairs of particles with different masses. In cases where the flight path is not known, a calib ration can be determined by using the TOF differences of two pair combinations of three particles. A Cherenkov detector, read out by a radio frequency photomultiplier tube, is considered as the high-resolution and highly stable TOF detector. By means of Monte Carlo simulations it is demonstrated that the magnetic spectrometers at the MAMI electron-scattering facility can be calibrated absolutely with an accuracy $delta p/pleq 10^{-4}$, which will be crucial for high precision determination of hypernuclear masses.
Full exploitation of the physics potential of a future International Linear Collider will require the use of polarized electron and positron beams. Experiment E166 at the Stanford Linear Accelerator Center (SLAC) has demonstrated a scheme in which an electron beam passes through a helical undulator to generate photons (whose first-harmonic spectrum extended to 7.9MeV) with circular polarization, which are then converted in a thin target to generate longitudinally polarized positrons and electrons. The experiment was carried out with a one-meter-long, 400-period, pulsed helical undulator in the Final Focus Test Beam (FFTB) operated at 46.6GeV. Measurements of the positron polarization have been performed at five positron energies from 4.5 to 7.5MeV. In addition, the electron polarization has been determined at 6.7MeV, and the effect of operating the undulator with a ferrofluid was also investigated. To compare the measurements with expectations, detailed simulations were made with an upgraded version of Geant4 that includes the dominant polarization-dependent interactions of electrons, positrons, and photons with matter. The measurements agree with calculations, corresponding to 80% polarization for positrons near 6MeV and 90% for electrons near 7MeV.
The longitudinal and transverse beam coupling impedance of the first final TOTEM Roman Pot unit has been measured in the laboratory with the wire method. For the evaluation of transverse impedance the wire position has been kept constant, and the ins ertions of the RP were moved asymmetrically. With the original configuration of the RP, resonances with fairly high Q values were observed. In order to mitigate this problem, RF-absorbing ferrite plates were mounted in appropriate locations. As a result, all resonances were sufficiently damped to meet the stringent LHC beam coupling impedance requirements.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا