ترغب بنشر مسار تعليمي؟ اضغط هنا

Prompted by intriguing events observed in certain particle-physics searches for rare events, we study light and acoustic emission simultaneously in some inorganic scintillators subject to mechanical stress. We observe mechanoluminescence in ${Bi}_4{G e}_{3}{O}_{12}$, ${CdWO}_{4}$ and ${ZnWO}_{4}$, in various mechanical configurations at room temperature and ambient pressure. We analyze how the light emission is correlated to acoustic emission during fracture. For ${Bi}_4{Ge}_{3}{O}_{12}$, we set a lower bound on the energy of the emitted light, and deduce that the fraction of elastic energy converted to light is at least $3 times 10^{-5}$.
We present some aspects of photon counting to study scintillators at low temperatures. A time-to-digital converter (TDC) had been configured to acquire several-minute-long streams of data, simplifying the multiple photon counting coincidence techniqu e. Results in terms of light yield and time structure of a ZnWO4 scintillator are comparable to those obtained with a fast digitizer. Streaming data also provides flexibility in analyzing the data, in terms of coincidence window between the channels, and acquisition window of individual channels. We discuss the effect of changing these parameters, and use them to confirm low-energy features in the spectra of the number of detected photons, such as the 60 keV line from 241Am in the ZnWO4 sample. We lastly use the TDC to study the transmission of the optical cryostat employed in these studies at various temperatures.
The CDMS and EDELWEISS collaborations have combined the results of their direct searches for dark matter using cryogenic germanium detectors. The total data set represents 614 kg.d equivalent exposure. A straightforward method of combination was chos en for its simplicity before data were exchanged between experiments. The results are interpreted in terms of limits on spin-independent WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90% CL. At higher WIMP masses, the combination improves the individual limits, by a factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide stronger constraints for some ranges of WIMP masses and weaker constraints for others.
74 - J. Astrom 2007
We analyze large sets of energy-release data created by stress-induced brittle fracture in a pure sapphire crystal at close to zero temperature where stochastic fluctuations are minimal. The waiting-time distribution follows that observed for fractur e in rock and for earthquakes. Despite strong time correlations of the events and the presence of large-event precursors, simple prediction algorithms only succeed in a very weak probabilistic sense. We also discuss prospects for further cryogenic experiments reaching close to single-bond sensitivity and able to investigate the existence of a transition-stress regime.
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا