ترغب بنشر مسار تعليمي؟ اضغط هنا

The German-British laser-interferometric gravitational wave detector GEO 600 is in its 13th year of operation since its first lock in 2001. After participating in science runs with other first generation detectors, GEO,600 has continued collecting da ta as an astrowatch instrument with a duty cycle of 62% during the time when the other detectors have gone offline to undergo substantial upgrades. Less invasive upgrades to demonstrate advanced technologies and improve the GEO 600 sensitivity at high frequencies as part of the GEO-HF program have additionally been carried out in parallel to data taking. We report briefly on the status of GEO 600.
Ground-based laser interferometers for gravitational-wave (GW) detection were first constructed starting 20 years ago and as of 2010 collection of several years worth of science data at initial design sensitivities was completed. Upgrades to the init ial detectors together with construction of brand new detectors are ongoing and feature advanced technologies to improve the sensitivity to GWs. This conference proceeding provides an overview of the common design features of ground-based laser interferometric GW detectors and establishes the context for the status updates of each of the four gravitational-wave detectors around the world: Advanced LIGO, Advanced Virgo, GEO600 and KAGRA.
Quantum noise will be the dominant noise source for the advanced laser interferometric gravitational wave detectors currently under construction. Squeezing-enhanced laser interferometers have been recently demonstrated as a viable technique to reduce quantum noise. We propose two new methods of generating an error signal for matching the longitudinal phase of squeezed vacuum states of light to the phase of the laser interferometer output field. Both provide a superior signal to the one used in previous demonstrations of squeezing applied to a gravitational-wave detector. We demonstrate that the new signals are less sensitive to misalignments and higher order modes, and result in an improved stability of the squeezing level. The new signals also offer the potential of reducing the overall rms phase noise and optical losses, each of which would contribute to achieving a higher level of squeezing. The new error signals are a pivotal development towards realizing the goal of 6 dB and more of squeezing in advanced detectors and beyond.
We describe the angular sensing and control of the 4 km detectors of the Laser Interferometer Gravitational-wave Observatory (LIGO). The culmination of first generation LIGO detectors, Enhanced LIGO operated between 2009 and 2010 with about 40 kW of laser power in the arm cavities. In this regime, radiation pressure effects are significant and induce instabilities in the angular opto-mechanical transfer functions. Here we present and motivate the angular sensing and control (ASC) design in this extreme case and present the results of its implementation in Enhanced LIGO. Highlights of the ASC performance are: successful control of opto-mechanical torsional modes, relative mirror motions of 1x10^{-7} rad rms, and limited impact on in-band strain sensitivity.
We present the design and performance of the LIGO Input Optics subsystem as implemented for the sixth science run of the LIGO interferometers. The Initial LIGO Input Optics experienced thermal side effects when operating with 7 W input power. We designed, built, and implemented improv
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا