ترغب بنشر مسار تعليمي؟ اضغط هنا

Multipulse sequences based on Carr-Purcell decoupling are frequently used for narrow-band signal detection in single spin magnetometry. We have analyzed the behavior of multipulse sensing sequences under real-world conditions, including finite pulse durations and the presence of detunings. We find that these non-idealities introduce harmonics to the filter function, allowing additional frequencies to pass the filter. In particular, we find that the XY family of sequences can generate signals at the 2fac, 4fac and 8fac harmonics and their odd subharmonics, where fac is the ac signal frequency. Consideration of the harmonic response is especially important for diamond-based nuclear spin sensing where the NMR frequency is used to identify the nuclear spin species, as it leads to ambiguities when several isotopes are present.
We present measurements of spin relaxation times (T_1, T_1,rho, T_2) on very shallow (<5 nm) nitrogen-vacancy (NV) centers in high-purity diamond single crystals. We find a reduction of spin relaxation times up to 30x compared to bulk values, indicat ing the presence of ubiquitous magnetic impurities associated with the surface. Our measurements yield a density of 0.01-0.1 Bohr magnetons per nm^2 and a characteristic correlation time of 0.28(3) ns of surface states, with little variation between samples (implanted, N-doped) and surface terminations (H, F and O). A low temperature measurement further confirms that fluctuations are thermally activated. The data support the atomistic picture where impurities are associated with the top carbon layers, and not with terminating surface atoms or adsorbate molecules. The low spin density implies that the presence of a single surface impurity is sufficient to cause spin relaxation of a shallow NV center.
137 - M. Loretz , T. Rosskopf , 2012
We experimentally demonstrate a simple and robust protocol for the detection of weak radio-frequency magnetic fields using a single electron spin in diamond. Our method relies on spin locking, where the Rabi frequency of the spin is adjusted to match the MHz signal frequency. In a proof-of-principle experiment we detect a 7.5 MHz magnetic probe field of 40 nT amplitude with <10 kHz spectral resolution over a T_1-limited noise floor of 0.3 nT/rtHz. Rotating-frame magnetometry may provide a direct and sensitive route to high-resolution spectroscopy of nanoscale nuclear spin signals.
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا