ترغب بنشر مسار تعليمي؟ اضغط هنا

We discuss the effect of atmospheric dispersion on the performance of a mid-infrared adaptive optics assisted instrument on an extremely large telescope (ELT). Dispersion and atmospheric chromaticity is generally considered to be negligible in this w avelength regime. It is shown here, however, that with the much-reduced diffraction limit size on an ELT and the need for diffraction-limited performance, refractivity phenomena should be carefully considered in the design and operation of such an instrument. We include an overview of the theory of refractivity, and the influence of infrared resonances caused by the presence of water vapour and other constituents in the atmosphere. `Traditional atmospheric dispersion is likely to cause a loss of Strehl only at the shortest wavelengths (L-band). A more likely source of error is the difference in wavelengths at which the wavefront is sensed and corrected, leading to pointing offsets between wavefront sensor and science instrument that evolve with time over a long exposure. Infrared radiation is also subject to additional turbulence caused by the presence of water vapour in the atmosphere not seen by visible wavefront sensors, whose effect is poorly understood. We make use of information obtained at radio wavelengths to make a first-order estimate of its effect on the performance of a mid-IR ground-based instrument. The calculations in this paper are performed using parameters from two different sites, one `standard good site and one `high and dry site to illustrate the importance of the choice of site for an ELT.
100 - S. Kendrew 2007
MIDIR is the proposed thermal/mid-IR imager and spectrograph for the European Extremely Large Telescope (E-ELT). It will cover the wavelength range of 3 to at least 20 microns. Designed for diffraction-limited performance over the entire wavelength r ange, MIDIR will require an adaptive optics system; a cryogenically cooled system could offer optimal performance in the IR, and this is a critical aspect of the instrument design. We present here an overview of the project, including a discussion of MIDIRs science goals and a comparison with other infrared (IR) facilities planned in the next decade; top level requirements derived from these goals are outlined. We describe the optical and mechanical design work carried out in the context of a conceptual design study, and discuss some important issues to emerge from this work, related to the design, operation and calibration of the instrument. The impact of telescope optical design choices on the requirements for the MIDIR instrument is demonstrated.
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا