ترغب بنشر مسار تعليمي؟ اضغط هنا

122 - T.Igarashi , S.Naka , M.Tanaka 2015
A new type of the Multi-Pixel Photon Counter (MPPC), sensitive to Vacuum Ultra-Violet (VUV) light (wavelength {lambda} < 150 nm), is recently developed and produced by Hamamatsu Photonics K.K. The basic properties of the new MPPC are measured at cryo genic facility of Waseda university using liquid nitrogen. Temperature dependence of breakdown voltage, capacitance, and dark count rate of the MPPC are also evaluated. In addition, the absolute photon detection efficiency (PDE) for liquid argon (LAr) scintillation light ({lambda} = 128 nm) is estimated to be about 7% with uncertainty of 2% by using 241 Am {alpha}-ray source. Based on these basic measurements a possible application of the new MPPC to LAr detector for dark matter search is discussed.
87 - M.Iye , M.Tanaka , M.Yanagisawa 2007
We report the serendipitous findings of 13 faint meteors and 44 artificial space objects by Subaru SuprimeCam imaging observations during 11-16 August 2004. The meteors, at about 100km altitude, and artificial satellites/debris in orbit, at 500km alt itude or higher, were clearly discriminated by their apparent defocused image sizes. CCD photometry of the 13 meteors, including 1 Perseid, 1 Aquarid, and 11 sporadic meteors, was performed. We defined a peak video-rate magnitude by comparing the integrated photon counts from the brightest portion of the track traversed within 33ms to those from a 0-mag star during the same time duration. This definition gives magnitudes in the range 4.0< V_{vr} <6.4 and 4.1< I_{vr}<5.9 for these 13 meteors. The corresponding magnitude for virtual naked-eye observers could be somewhat fainter especially for the V-band observation, in which the [OI] 5577 line lasting about 1 sec as an afterglow could contribute to the integrated flux of the present 5-10 min CCD exposures. Although the spatial resolution is insufficient to resolve the source size of anything smaller than about 1 m, we developed a new estimate of the collisionally excited column diameter of these meteors. A diameter as small as a few mm was derived from their collisionally excited photon rates, meteor speed, and the volume density of the oxygen atoms at the 100km altitude. The actual column diameter of the radiating zone, however, could be as large as few 100m because the excited atoms travel that distance before they emit forbidden lines in 0.7 sec of its average lifetime. Among the 44 artificial space objects, we confirmed that 17 were cataloged satellites/space debris.
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا