95 - G. Zahnd , L. Vila , T. V. Pham 2015
Spin injection and detection in Co60Fe40-based all-metallic lateral spin-valves have been studied at both room and low temperatures. The obtained spin signals amplitudes have been compared to that of identical Ni80Fe20-based devices. The replacement of Ni80Fe20 by CoFe allows increasing the spin signal amplitude by up to one order of magnitude, thus reaching 50 m{Omega} at room temperature. The spin signal dependence with the distance between the ferromagnetic electrodes has been analyzed using both a 1D spin transport model and finite elements method simulations. The enhancement of the spin signal amplitude when using CoFe electrodes can be explained by a higher effective polarization.