ترغب بنشر مسار تعليمي؟ اضغط هنا

In this paper, we report new limits on 21cm emission from cosmic reionization based on a 135-day observing campaign with a 64-element deployment of the Donald C. Backer Precision Array for Probing the Epoch of Reionization (PAPER) in South Africa. Th is work extends the work presented in Parsons et al. (2014) with more collecting area, a longer observing period, improved redundancy-based calibration, optimal fringe-rate filtering, and improved power-spectral analysis using optimal quadratic estimators. The result is a new $2sigma$ upper limit on $Delta^{2}(k)$ of (22.4 mK)$^2$ in the range $0.15 < k < 0.5h {rm Mpc}^{-1}$ at $z = 8.4$. This represents a three-fold improvement over the previous best upper limit. As we discuss in more depth in a forthcoming paper (Pober et al. 2015, in prep), this upper limit supports and extends previous evidence against extremely cold reionization scenarios. We conclude with a discussion of implications for future 21cm reionization experiments, including the newly funded Hydrogen Epoch of Reionization Array (HERA). $textbf{The limits presented in this paper have been retracted: The erratum can be found in Appendix A.}$
We report on the MIT Epoch of Reionization (MITEoR) experiment, a pathfinder low-frequency radio interferometer whose goal is to test technologies that improve the calibration precision and reduce the cost of the high-sensitivity 3D mapping required for 21 cm cosmology. MITEoR accomplishes this by using massive baseline redundancy, which enables both automated precision calibration and correlator cost reduction. We demonstrate and quantify the power and robustness of redundancy for scalability and precision. We find that the calibration parameters precisely describe the effect of the instrument upon our measurements, allowing us to form a model that is consistent with $chi^2$ per degree of freedom < 1.2 for as much as 80% of the observations. We use these results to develop an optimal estimator of calibration parameters using Wiener filtering, and explore the question of how often and how finely in frequency visibilities must be reliably measured to solve for calibration coefficients. The success of MITEoR with its 64 dual-polarization elements bodes well for the more ambitious Hydrogen Epoch of Reionization Array (HERA) project and other next-generation instruments, which would incorporate many identical or similar technologies.
Mapping our universe in 3D by imaging the redshifted 21 cm line from neutral hydrogen has the potential to overtake the cosmic microwave background as our most powerful cosmological probe, because it can map a much larger volume of our Universe, shed ding new light on the epoch of reionization, inflation, dark matter, dark energy, and neutrino masses. We report on MITEoR, a pathfinder low-frequency radio interferometer whose goal is to test technologies that greatly reduce the cost of such 3D mapping for a given sensitivity. MITEoR accomplishes this by using massive baseline redundancy both to enable automated precision calibration and to cut the correlator cost scaling from N^2 to NlogN, where N is the number of antennas. The success of MITEoR with its 64 dual-polarization elements bodes well for the more ambitious HERA project, which would incorporate many identical or similar technologies using an order of magnitude more antennas, each with dramatically larger collecting area.
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا