ترغب بنشر مسار تعليمي؟ اضغط هنا

We present the first experimental test that distinguishes between an event-based corpuscular model (EBCM) [H. De Raedt et al.: J. Comput. Theor. Nanosci. 8 (2011) 1052] of the interaction of photons with matter and quantum mechanics. The test looks a t the interference that results as a single photon passes through a Mach-Zehnder interferometer [H. De Raedt et al.: J. Phys. Soc. Jpn. 74 (2005) 16]. The experimental results, obtained with a low-noise single-photon source [G. Brida et al.: Opt. Expr. 19 (2011) 1484], agree with the predictions of standard quantum mechanics with a reduced $chi^2$ of 0.98 and falsify the EBCM with a reduced $chi^2$ of greater than 20.
In counterfactual QKD information is transfered, in a secure way, between Alice and Bob even when no particle carrying the information is in fact transmitted between them. In this letter we fully implement the scheme for counterfactual QKD proposed i n [T. Noh, PRL textbf{103}, 230501 (2009)], demonstrating for the first time that information can be transmitted between two parties without the transmission of a carrier.
Recently a test of nonclassicality for a single qubit was proposed [R. Alicki and N. Van Ryn, J. Phys. A: Math. Theor. 41, 062001 (2008)]. We present an optimized experimental realization of this test leading to a 46 standard deviation violation of c lassicality. This factor of 5 improvement over our previous result was achieved by moving from the infrared to the visible where we can take advantage of higher efficiency and lower noise photon detectors.
Spontaneous parametric down conversion (SPDC) has been largely exploited as a tool for absolute calibration of photon-counting detectors, i.e detectors registering very small photon fluxes. In [J. Opt. Soc. Am. B 23, 2185 (2006)] we derived a method for absolute calibration of analog detectors using SPDC emission at higher photon fluxes, where the beam is seen as a continuum by the detector. Nevertheless intrinsic limitations appear when high-gain regime of SPDC is required to reach even larger photon fluxes. Here we show that stimulated parametric down conversion allow one to avoid this limitation, since stimulated photon fluxes are increased by the presence of the seed beam.
In this paper we report our systematic study of a promising absolute calibration technique of analog photo-detectors, based on the properties of parametric down conversion. Our formal results and a preliminary uncertainty analysis show that the propo sed method can be effectively developed with interesting applications to metrology.
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا