ترغب بنشر مسار تعليمي؟ اضغط هنا

High-resolution X-ray spectrometers onboard suborbital sounding rockets can search for dark matter candidates that produce X-ray lines, such as decaying keV-scale sterile neutrinos. Even with exposure times and effective areas far smaller than XMM-Ne wton and Chandra observations, high-resolution, wide field-of-view observations with sounding rockets have competitive sensitivity to decaying sterile neutrinos. We analyze a subset of the 2011 observation by the X-ray Quantum Calorimeter instrument centered on Galactic coordinates l = 165, b = -5 with an effective exposure of 106 seconds, obtaining a limit on the sterile neutrino mixing angle of sin^2(2 theta) < 7.2e-10 at 95% CL for a 7 keV neutrino. Better sensitivity at the level of sin^2(2 theta) ~ 2.1e-11 at 95% CL for a 7 keV neutrino is achievable with future 300-second observations of the galactic center by the Micro-X instrument, providing a definitive test of the sterile neutrino interpretation of the reported 3.56 keV excess from galaxy clusters.
The baseline energy-resolution performance for the current generation of large-mass, low-temperature calorimeters (utilizing TES and NTD sensor technologies) is $>2$ orders of magnitude worse than theoretical predictions. A detailed study of several calorimetric detectors suggests that a mismatch between the sensor and signal bandwidths is the primary reason for suppressed sensitivity. With this understanding, we propose a detector design in which a thin-film Au pad is directly deposited onto a massive absorber that is then thermally linked to a separately fabricated TES chip via an Au wirebond, providing large electron-phonon coupling (i.e. high signal bandwidth), ease of fabrication, and cosmogenic background suppression. Interestingly, this design strategy is fully compatible with the use of hygroscopic crystals (NaI) as absorbers. An 80-mm diameter Si light detector based upon these design principles, with potential use in both dark matter and neutrinoless double beta decay, has an estimated baseline energy resolution of 0.35 eV, 20$times$ better than currently achievable. A 1.75 kg ZnMoO$_{4}$ large-mass calorimeter would have a 3.5 eV baseline resolution, 1000$times$ better than currently achieved with NTDs with an estimated position dependence $frac{Delta E}{E}$ of 6$times$10$^{-4}$. Such minimal position dependence is made possible by forcing the sensor bandwidth to be much smaller than the signal bandwidth. Further, intrinsic event timing resolution is estimated to be $sim$170 $mu$s for 3 MeV recoils in the phonon detector, satisfying the event-rate requirements of large $Q_{beta beta}$ next-generation neutrinoless double beta decay experiments. Quiescent bias power for both of these designs is found to be significantly larger than parasitic power loads achieved in the SPICA/SAFARI infrared bolometers.
We present the analysis of 21 bright X-ray knots in the Cassiopeia A supernova remnant from observations spanning 10 yr. We performed a comprehensive set of measurements to reveal the kinematic and thermal state of the plasma in each knot, using a co mbined analysis of two high energy resolution High Energy Transmission Grating (HETG) and four medium energy resolution Advanced CCD Imaging Spectrometer (ACIS) sets of spectra. The ACIS electron temperature estimates agree with the HETG-derived values for approximately half of the knots studied, yielding one of the first comparisons between high resolution temperature estimates and ACIS-derived temperatures. We did not observe the expected spectral evolutionpredicted from the ionization age and density estimates for each knotin all but three of the knots studied. The incompatibility of these measurements with our assumptions has led us to propose a dissociated ejecta model, with the metals unmixed inside the knots, which could place strong constraints on supernova mixing models.
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا