ترغب بنشر مسار تعليمي؟ اضغط هنا

In this paper we derived oxygen abundance gradients from HII regions located in eleven galaxies in eight systems of close pairs. Long-slit spectra in the range 4400-7300A were obtained with the Gemini Multi-Object Spec- trograph at Gemini South (GMOS ). Spatial profiles of oxygen abundance in the gaseous phase along galaxy disks were obtained using calibrations based on strong emission-lines (N2 and O3N2). We found oxygen gradients signifi- cantly flatter for all the studied galaxies than those in typical isolated spiral galaxies. Four objects in our sample, AM1219A, AM1256B, AM 2030A and AM2030B, show a clear break in the oxygen abundance at galactocentric radius R/R25 between 0.2 and 0.5. For AM1219A and AM1256B we found negative slopes for the inner gradients, and for AM2030B we found a positive one. In all these three cases they show a flatter behaviour to the outskirts of the galaxies. For AM2030A, we found a positive-slope outer gradient while the inner one is almost compatible with a flat behaviour. A decrease of star forma- tion efficiency in the zone that corresponds to the oxygen abundance gradient break for AM1219A and AM2030B was found. For the former, a minimum in the estimated metallicities was found very close to the break zone that could be associated with a corotation radius. On the other hand, AM1256B and AM2030A, present a SFR maximum but not an extreme oxygen abundance value. All the four interacting systems that show oxygen gradient breakes the extreme SFR values are located very close to break zones. Hii regions lo- cated in close pairs of galaxies follow the same relation between the ionization parameter and the oxygen abundance as those regions in isolated galaxies.
We employed observational spectroscopic data of star-forming regions compiled from the literature and photoionization models to analyse the neon ionic abundances obtained using both optical and mid-infrared emission-lines. Comparing Ne++/H+ ionic abu ndances from distinct methods, we found that, in average, the abundances obtained via IR emission-lines are higher than those obtained via optical lines by a factor of 4. Photoionization models with abundance variations along the radius of the hypothetical nebula provide a possible explanation for a large part of the difference between ionic abundances via optical and infrared emission-lines. Ionization Correction Factor (ICF) for the neon is obtained from direct determinations of ionic fractions using infrared emission-lines. A constant Ne/O ratio (logNe/O approx -0.70) for a large range of metallicity, independently of the ICF used to compute the neon total abundance is derived.
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا