ترغب بنشر مسار تعليمي؟ اضغط هنا

243 - Cindy R. Tam 2007
We present the results of X-ray and near-IR observations of the anomalous X-ray pulsar 1E 1048.1-5937, believed to be a magnetar. This AXP underwent a period of extreme variability during 2001-2004, but subsequently entered an extended and unexpected quiescence in 2004-2006, during which we monitored it with RXTE, CXO, and HST. Its timing properties were stable for >3 years throughout the quiescent period. 1E 1048.1-5937 again went into outburst in March 2007, which saw a factor of >7 total X-ray flux increase which was anti-correlated with a pulsed fraction decrease, and correlated with spectral hardening, among other effects. The near-IR counterpart also brightened following the 2007 event. We discuss our findings in the context of the magnetar and other models.
97 - Cindy R. Tam 2007
(Abridged) We report on new and archival X-ray and near-infrared observations of the anomalous X-ray pulsar 1E 1048.1-5937 performed between 2001-2007 with RXTE, CXO, Swift, HST, and VLT. During its ~2001-2004 active period, 1E 1048.-5937 exhibited t wo large, long-term X-ray pulsed-flux flares as well as short bursts, and large (>10x) torque changes. Monitoring with RXTE revealed that the source entered a phase of timing stability in 2004; at the same time, a series of four simultaneous observations with CXO and HST in 2006 showed that its X-ray flux and spectrum and near-IR flux, all variable prior to 2005, stabilized. The near-IR flux, when detected by HST (H~22.7 mag) and VLT (K_S~21.0 mag), was considerably fainter than previously measured. Recently, in 2007 March, this newfound quiescence was interrupted by a sudden flux enhancement, X-ray spectral changes and a pulse morphology change, simultaneous with a large spin-up glitch and near-IR enhancement. Our RXTE observations revealed a sudden pulsed flux increase by a factor of ~3 in the 2-10 keV band. In observations with CXO and Swift, we found that the total X-ray flux increased much more than the pulsed flux, reaching a peak value of >7 times the quiescent value (2-10 keV). With these recent data, we find a strong anti-correlation between X-ray flux and pulsed fraction, and a correlation between X-ray spectral hardness and flux. Simultaneously with the radiative and timing changes, we observed a significant X-ray pulse morphology change such that the profile went from nearly sinusoidal to having multiple peaks. We compare these remarkable events with other AXP outbursts and discuss implications in the context of the magnetar model and other models of AXP emission.
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا