Do you want to publish a course? Click here

Indirect dark matter search with the balloon-borne PEBS detector

106   0   0.0 ( 0 )
 Added by Henning Gast
 Publication date 2009
  fields Physics
and research's language is English




Ask ChatGPT about the research

A precision measurement of the cosmic-ray positron spectrum may help to solve the puzzle of the nature of dark matter. Pairwise annihilation of neutralinos, predicted by some supersymmetric extensions to the standard model of particle physics, may leave a distinct feature in the cosmic-ray positron spectrum. As the available data are limited both in terms of statistics and energy range, we are developing a balloon-borne detector (PEBS) with a large acceptance of 4000 cm^2 sr. A superconducting magnet creating a field of 0.8 T and a tracking device consisting of scintillating fibers of 0.25 mm diameter with silicon photomultiplier readout will allow rigidity and charge determination to energies above 100 GeV. The dominant proton background is suppressed by the combination of an electromagnetic calorimeter and a transition radiation detector consisting of fleece layers interspersed with straw-tube proportional counters. The calorimeter uses a sandwich of tungsten and scintillating fibers that are again read out by silicon photomultipliers.



rate research

Read More

120 - Ph. von Doetinchem 2009
This thesis discusses two different approaches for the measurement of cosmic-ray antiparticles in the GeV to TeV energy range. The first part of this thesis discusses the prospects of antiparticle flux measurements with the proposed PEBS detector. The project allots long duration balloon flights at one of Earths poles at an altitude of 40 km. GEANT4 simulations were carried out which determine the atmospheric background and attenuation especially for antiparticles. The second part covers the AMS-02 experiment which will be installed in 2010 on the International Space Station at an altitude of about 400 km for about three years to measure cosmic rays without the influence of Earths atmosphere. The present work focuses on the anticoincidence counter system (ACC). The ACC is needed to reduce the trigger rate during periods of high fluxes and to reject external particles crossing the tracker from the side or particles resulting from interactions within the detector which would otherwise disturb the clean charge and momentum measurements. The last point is especially important for the measurement of antinuclei and antiparticles.
PoGOLino is a balloon-borne scintillator-based experiment developed to study the largely unexplored high altitude neutron environment at high geomagnetic latitudes. The instrument comprises two detectors that make use of LiCAF, a novel neutron sensitive scintillator, sandwiched by BGO crystals for background reduction. The experiment was launched on March 20th 2013 from the Esrange Space Centre, Northern Sweden (geomagnetic latitude of $65^circ$), for a three hour flight during which the instrument took data up to an altitude of 30.9 km. The detector design and ground calibration results are presented together with the measurement results from the balloon flight.
We use existing light weight balloon facility of Indian Centre for Space Physics to detect the X-ray radiation from Crab pulsar with a phoswich detector. We present the design considerations and characterization of the detector used for this purpose. We model the background radiation in the detector environment at various altitudes and use this in spectral analysis. The background radiation level and limitations on the detector allowed us to calculate minimum detection limit for extrasolar radiation sources with our set up.
131 - Mark Pearce 2011
The physical processes postulated to explain the high-energy emission mechanisms of compact astrophysical sources often yield polarised soft gamma rays (X-rays). PoGOLite is a balloon-borne polarimeter operating in the 25-80 keV energy band. The polarisation of incident photons is reconstructed using Compton scattering and photoelectric absorption in an array of phoswich detector cells comprising plastic and BGO scintillators, surrounded by a BGO side anticoincidence shield. The polarimeter is aligned to observation targets using a custom attitude control system. The maiden balloon flight is scheduled for summer 2011 from the Esrange Space Centre with the Crab and Cygnus X-1 as the primary observational targets.
We present a new module of micrOMEGAs devoted to the computation of indirect signals from dark matter annihilation in any new model with a stable weakly interacting particle. The code provides the mass spectrum, cross-sections, relic density and exotic fluxes of gamma rays, positrons and antiprotons. The propagation of charged particles in the Galactic halo is handled with a new module that allows to easily modify the propagation parameters.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا