Do you want to publish a course? Click here

Sources Variability With Planck LFI

64   0   0.0 ( 0 )
 Added by Luca Terenzi
 Publication date 2002
  fields Physics
and research's language is English




Ask ChatGPT about the research

Planck LFI (Low Frequency Instrument) will produce a complete survey of the sky at millimeter wavelengths. Data stream analysis will provide the possibility to reveal unexpected millimeter sources and to study their flux evolution in time at different frequencies. We describe here the main implications and discuss data analysis methods. Planck sensitivities typical for this kind of detection are taken into account. We present also preliminary results of our simulation activity.



rate research

Read More

This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst This paper describes the Planck Low Frequency Instrument tuning activities performed through the ground test campaigns, from Unit to Satellite Levels. Tuning is key to achieve the best possible instrument performance and tuning parameters strongly depend on thermal and electrical conditions. For this reason tuning has been repeated several times during ground tests and it has been repeated in flight before starting nominal operations. The paper discusses the tuning philosophy, the activities and the obtained results, highlighting developments and changes occurred during test campaigns. The paper concludes with an overview of tuning performed during the satellite cryogenic test campaign (Summer 2008) and of the plans for the just started in-flight calibration.
The Planck Early Release Compact Source Catalogue includes 26 sources with no obvious matches in other radio catalogues (of primarily extragalactic sources). Here we present observations made with the Arcminute Microkelvin Imager Small Array (AMI SA) at 15.75 GHz of the eight of the unmatched sources at declination > +10 degrees. Of the eight, four are detected and are associated with known objects. The other four are not detected with the AMI SA, and are thought to be spurious.
The Low Frequency Instrument (LFI) is an array of pseudo-correlation radiometers on board the Planck satellite, the ESA mission dedicated to precision measurements of the Cosmic Microwave Background. The LFI covers three bands centred at 30, 44 and 70 GHz, with a goal bandwidth of 20% of the central frequency. The characterization of the broadband frequency response of each radiometer is necessary to understand and correct for systematic effects, particularly those related to foreground residuals and polarization measurements. In this paper we present the measured band shape of all the LFI channels and discuss the methods adopted for their estimation. The spectral characterization of each radiometer was obtained by combining the measured spectral response of individual units through a dedicated RF model of the LFI receiver scheme. As a consistency check, we also attempted end-to-end spectral measurements of the integrated radiometer chain in a cryogenic chamber. However, due to systematic effects in the measurement setup, only qualitative results were obtained from these tests. The measured LFI bandpasses exhibit a moderate level of ripple, compatible with the instrument scientific requirements.
The Planck Collaboration made its final data release in 2018. In this paper we describe beam-deconvolution map products made from Planck LFI data using the artDeco deconvolution code to symmetrize the effective beam. The deconvolution results are auxiliary data products, available through the Planck Legacy Archive. Analysis of these deconvolved survey difference maps reveals signs of residual signal in the 30-GHz and 44-GHz frequency channels. We produce low-resolution maps and corresponding noise covariance matrices (NCVMs). The NCVMs agree reasonably well with the half-ring noise estimates except for 44 GHz, where we observe an asymmetry between $EE$ and $BB$ noise spectra, possibly a sign of further unresolved systematics.
228 - J. P. Leahy 2001
The Planck Low Frequency Instrument will recover polarization by differencing the outputs from radiometers sensitive to orthogonal polarizations. We contrast the systematic errors that afflict such a system with those that affect correlation polarimeters; the Planck design has some important advantages when measuring very weak signals such as the CMB. We also review systematic effects arising from the choice of scan strategy for all-sky mapping missions like Planck.[For the Planck-LFI consortium].
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا