This paper presents lessons learned to date during the Coronavirus Disease 2019 (COVID-19) pandemic from the viewpoint of Saskatchewan power system operations. A load estimation approach is developed to identify how the closures affecting businesses, schools, and other non-critical businesses due to COVID-19 changed the electricity consumption. Furthermore, the impacts of COVID-19 containment measures and re-opening phases on load uncertainty are examined. Changes in CO2 emissions resulting from an increased proportion of renewable energy generation and the change in load pattern are discussed. In addition, the influence of COVID-19 on the balancing authoritys power control performance is investigated. Analyses conducted in the paper are based upon data from SaskPower corporation, which is the principal electric utility in Saskatchewan, Canada. Some recommendations for future power system operation and planning are developed.
This paper provides a detailed account of the impact of different offshore wind siting strategies on the design of the European power system. To this end, a two-stage method is proposed. In the first stage, a highly-granular siting problem identifies a suitable set of sites where offshore wind plants could be deployed according to a pre-specified criterion. Two siting schemes are analysed and compared within a realistic case study. These schemes essentially select a pre-specified number of sites so as to maximise their aggregate power output and their spatiotemporal complementarity, respectively. In addition, two variants of these siting schemes are provided, wherein the number of sites to be selected is specified on a country-by-country basis rather than Europe-wide. In the second stage, the subset of previously identified sites is passed to a capacity expansion planning (CEP) framework that sizes the power generation, transmission and storage assets that should be deployed and operated in order to satisfy pre-specified electricity demand levels at minimum cost. Results show that the complementarity-based siting criterion leads to system designs which are up to 5% cheaper than the ones relying the power output-based criterion when offshore wind plants are deployed with no consideration for country-based deployment targets. On the contrary, the power output-based scheme leads to system designs which are consistently 2% cheaper than the ones leveraging the complementarity-based siting strategy when such constraints are enforced. The robustness of the results is supported by a sensitivity analysis on offshore wind capital expenditure and inter-annual weather variability, respectively.
In modern power grids, a local failure or attack can trigger catastrophic cascading failures, which make it challenging to assess the attack vulnerability of power grids. In this Brief, we define the $K$-link attack problem and study the attack vulnerability of power grids under cascading failures. Particularly, we propose a link centrality measure based on both topological and electrical properties of power grids. According to this centrality, we propose a greedy attack algorithm and an optimal attack algorithm. Simulation results on standard IEEE bus test data show that the optimal attack is better than the greedy attack and the traditional PSO-based attack in fracturing power grids. Moreover, the greedy attack has smaller computational complexity than the optimal attack and the PSO-based attack with an adequate attack efficiency. Our work helps to understand the vulnerability of power grids and provides some clues for securing power grids.
The first-ever Ukraine cyberattack on power grid has proven its devastation by hacking into their critical cyber assets. With administrative privileges accessing substation networks/local control centers, one intelligent way of coordinated cyberattacks is to execute a series of disruptive switching executions on multiple substations using compromised supervisory control and data acquisition (SCADA) systems. These actions can cause significant impacts to an interconnected power grid. Unlike the previous power blackouts, such high-impact initiating events can aggravate operating conditions, initiating instability that may lead to system-wide cascading failure. A systemic evaluation of nightmare scenarios is highly desirable for asset owners to manage and prioritize the maintenance and investment in protecting their cyberinfrastructure. This survey paper is a conceptual expansion of real-time monitoring, anomaly detection, impact analyses, and mitigation (RAIM) framework that emphasizes on the resulting impacts, both on steady-state and dynamic aspects of power system stability. Hypothetically, we associate the combinatorial analyses of steady state on substations/components outages and dynamics of the sequential switching orders as part of the permutation. The expanded framework includes (1) critical/noncritical combination verification, (2) cascade confirmation, and (3) combination re-evaluation. This paper ends with a discussion of the open issues for metrics and future design pertaining the impact quantification of cyber-related contingencies.
Given the increasing penetration in renewable generation, the UK power system is experiencing a decline in system inertia and an increase in frequency response (FR) requirements. Faster FR products are a mitigating solution that can cost-effectively meet the system balancing requirements. Thus, this paper proposes a mixed integer linear programming (MILP) unit commitment model which can simultaneously schedule inertial response, mandatory FR, as well as a sub-second FR product - enhanced frequency response (EFR). The model quantifies the value of providing faster reacting FR products in comparison with other response times from typical FR products. The performance and value of EFR are determined in a series of future energy scenarios with respect to the UK market and system conditions.
Many of the control policies that were put into place during the Covid-19 pandemic had a common goal: to flatten the curve of the number of infected people so that its peak remains under a critical threshold. This letter considers the challenge of engineering a strategy that enforces such a goal using control theory. We introduce a simple formulation of the optimal flattening problem, and provide a closed form solution.This is augmented through nonlinear closed loop tracking of the nominal solution, with the aim of ensuring close-to-optimal performance under uncertain conditions. A key contribution ofthis paper is to provide validation of the method with extensive and realistic simulations in a Covid-19 scenario, with particular focus on the case of Codogno - a small city in Northern Italy that has been among the most harshly hit by the pandemic.