Modeling the e-APD SAPHIRA/C-RED ONE camera at low flux level: an attempt of photon counting in the near-infrared with the MIRC-X interferometric combiner

121   0   0.0 ( 0 )
 Added by Cyprien Lanthermann
 Publication date 2019
  fields Physics
and research's language is English




Ask ChatGPT about the research

We implement an electron avalanche photodiode (e-APD) in the MIRC-X instrument, upgrade of the 6-telescope near-infrared imager MIRC, at the CHARA array. This technology should improve the sensitivity of near-infrared interferometry. We first used the classical Mean-Variance analysis to measure the system gain and the amplification gain. We then developed a physical model of the statistical distribution of the camera output signal. This model is based on multiple convolutions of the Poisson statistic, the intrinsic avalanche gain distribution, and the observed distribution of the background signal. At low flux level, this model constraints independently the incident illumination level, the total gain, and the excess noise factor of the amplification. We measure a total transmission of $48pm3%$ including the cold filter and the Quantum Efficiency. We measure a system gain of 0.49 ADU/e, a readout noise of $10$ ADU, and amplification gains as high as 200. These results are consistent between the two methods and therefore validate our modeling approach. The measured excess noise factor based on the modeling is $1.47pm0.03$, with no obvious dependency with flux level or amplification gain. The presented model allows measuring the characteristics of the e-APD array at low flux level independently of preexisting calibration. With $<0.3$,electron equivalent readout noise at kilohertz frame rates, we confirm the revolutionary performances of the camera with respect to the PICNIC or HAWAII technologies. However, the measured excess noise factor is significantly higher than the one claimed in the literature ($<$1.25), and explains why counting multiple photons remains challenging with this camera.



rate research

Read More

MIRC-X (Michigan InfraRed Combiner-eXeter) is a new highly-sensitive six-telescope interferometric imager installed at the CHARA Array that provides an angular resolution equivalent of up to a 330 m diameter baseline telescope in J and H band wavelengths ($tfrac{lambda}{2B}sim0.6$ milli-arcseconds). We upgraded the original MIRC (Michigan InfraRed Combiner) instrument to improve sensitivity and wavelength coverage in two phases. First, a revolutionary sub-electron noise and fast-frame rate C-RED ONE camera based on a SAPHIRA detector was installed. Second, a new-generation beam combiner was designed and commissioned to (i) maximize sensitivity, (ii) extend the wavelength coverage to J-band, and (iii) enable polarization observations. A low-latency and fast-frame rate control software enables high-efficiency observations and fringe tracking for the forthcoming instruments at CHARA Array. Since mid-2017, MIRC-X has been offered to the community and has demonstrated best-case H-band sensitivity down to 8.2 correlated magnitude. MIRC-X uses single-mode fibers to coherently combine light of six telescopes simultaneously with an image-plane combination scheme and delivers a visibility precision better than 1%, and closure phase precision better than $1^circ$. MIRC-X aims at (i) imaging protoplanetary disks, (ii) detecting exoplanets with precise astrometry, and (iii) imaging stellar surfaces and star-spots at an unprecedented angular resolution in the near-infrared. In this paper, we present the instrument design, installation, operation, and on-sky results, and demonstrate the imaging and astrometric capability of MIRC-X on the binary system $iota$ Peg. The purpose of this paper is to provide a solid reference for studies based on MIRC-X data and to inspire future instruments in optical interferometry.
We have developed a sensor system based on an optical photon-counting imager with high timing resolution, aiming for highly time-variable astronomical phenomena. The detector is a monolithic Geiger-mode avalanche photodiode array customized in a Multi-Pixel Photon Counter with a response time on the order of nanoseconds. This paper evaluates the basic performance of the sensor and confirms the gain linearity, uniformity, and low dark count. We demonstrate the systems ability to detect the period of a flashing LED, using a data acquisition system developed to obtain the light curve with a time bin of 100 microseconds. The Crab pulsar was observed using a 35-cm telescope without cooling, and the equipment detected optical pulses with a period consistent with the data from the radio ephemeris. Although improvements to the system will be necessary for more reliability, the system has been proven to be a promising device for exploring the time-domain optical astronomy.
We present the detailed design of the near infrared camera for the SuMIRe (Subaru Measurement of Images and Redshifts) Prime Focus Spectrograph (PFS) being developed for the Subaru Telescope. The PFS spectrograph is designed to collect spectra from 2394 objects simultaneously, covering wavelengths that extend from 380 nm - 1.26 um. The spectrograph is comprised of four identical spectrograph modules, with each module collecting roughly 600 spectra from a robotic fiber positioner at the telescope prime focus. Each spectrograph module will have two visible channels covering wavelength ranges 380 nm - 640 nm and 640 nm - 955 nm, and one near infrared (NIR) channel with a wavelength range 955 nm - 1.26 um. Dispersed light in each channel is imaged by a 300 mm focal length, f/1.07, vacuum Schmidt camera onto a 4k x 4k, 15 um pixel, detector format. For the NIR channel a HgCdTe substrate-removed Teledyne 1.7 um cutoff device is used. In the visible channels, CCDs from Hamamatsu are used. These cameras are large, having a clear aperture of 300 mm at the entrance window, and a mass of ~ 250 kg. Like the two visible channel cameras, the NIR camera contains just four optical elements: a two-element refractive corrector, a Mangin mirror, and a field flattening lens. This simple design produces very good imaging performance considering the wide field and wavelength range, and it does so in large part due to the use of a Mangin mirror (a lens with a reflecting rear surface) for the Schmidt primary. In the case of the NIR camera, the rear reflecting surface is a dichroic, which reflects in-band wavelengths and transmits wavelengths beyond 1.26 um. This, combined with a thermal rejection filter coating on the rear surface of the second corrector element, greatly reduces the out-of-band thermal radiation that reaches the detector.
We present details of characterization and imaging performance of the Cananea Near-infrared camera (CANICA) at the 2.1m telescope of the Guillermo Haro Astrophysical Observatory (OAGH) located in Cananea, Sonora, Mexico. CANICA has a HAWAII array with a HgCdTe detector of 1024 x 1024 pixels covering a field of view of 5.5 x 5.5 arcmin^2 with a plate scale of 0.32 arcsec/pixel. The camera characterization involved measuring key detector parameters: conversion gain, dark current, readout noise, and linearity. The pixels in the detector have a full-well-depth of 100,000 e- with the conversion gain measured to be 5.8 e-/ADU. The time-dependent dark current was estimated to be 1.2 e-/sec. Readout noise for correlated double sampled (CDS) technique was measured to be 30 e-/pixel. The detector shows 10% non-linearity close to the full-well-depth. The non-linearity was corrected within 1% levels for the CDS images. Full-field imaging performance was evaluated by measuring the point spread function, zeropoints, throughput, and limiting magnitude. The average zeropoint value in each filter are J = 20.52, H = 20.63, and K = 20.23. The saturation limit of the detector is about sixth magnitude in all the primary broadbands. CANICA on the 2.1m OAGH telescope reaches background-limited magnitudes of J = 18.5, H = 17.6, and K = 16.0 for a signal-to-noise ratio of 10 with an integration time of 900s.
The James Webb Space Telescope near-infrared camera (JWST NIRCam) has two 2.2 $times$ 2.2 fields of view that are capable of either imaging or spectroscopic observations. Either of two $R sim 1500$ grisms with orthogonal dispersion directions can be used for slitless spectroscopy over $lambda = 2.4 - 5.0$ $mu$m in each module, and shorter wavelength observations of the same fields can be obtained simultaneously. We present the latest predicted grism sensitivities, saturation limits, resolving power, and wavelength coverage values based on component measurements, instrument tests, and end-to-end modeling. Short wavelength (0.6 -- 2.3 $mu$m) imaging observations of the 2.4 -- 5.0 $mu$m spectroscopic field can be performed in one of several different filter bands, either in-focus or defocused via weak lenses internal to NIRCam. Alternatively, the possibility of 1.0 -- 2.0 $mu$m spectroscopy (simultaneously with 2.4 -- 5.0 $mu$m) using dispersed Hartmann sensors (DHSs) is being explored. The grisms, weak lenses, and DHS elements were included in NIRCam primarily for wavefront sensing purposes, but all have significant science applications. Operational considerations including subarray sizes, and data volume limits are also discussed. Finally, we describe spectral simulation tools and illustrate potential scientific uses of the grisms by presenting simulated observations of deep extragalactic fields, galactic dark clouds, and transiting exoplanets.