Do you want to publish a course? Click here

Study of Light Backgrounds from Relativistic Electrons in Air Light-Guides

62   0   0.0 ( 0 )
 Added by Yuxiang Zhao
 Publication date 2017
  fields Physics
and research's language is English




Ask ChatGPT about the research

The MOLLER experiment proposed at the Thomas Jefferson National Accelerator Facility plans a precision low energy determination of the weak mixing angle via the measurement of the parity-violating asymmetry in the scattering of high energy longitudinally polarized electrons from electrons bound in a liquid hydrogen target (M{o}ller scattering). A relative measure of the scattering rate is planned to be obtained by intercepting the M{o}ller scattered electrons with a circular array of thin fused silica tiles attached to air light guides, which facilitate the transport of Cherenkov photons generated within the tiles to photomultiplier tubes (PMTs). The scattered flux will also pass through the light guides of downstream tiles, generating additional Cherenkov as well as scintillation light and is a potential background. In order to estimate the rate of these backgrounds, a gas-filled tube detector was designed and deployed in an electron beam at the MAMI facility at Johannes Gutenberg University, Mainz, Germany. Described in this paper is the design of a detector to measure separately the scintillation and Cherenkov responses of gas mixtures from relativistic electrons, the results of studies of several gas mixtures with comparisons to simulations, and conclusions about the implications for the design of the MOLLER detector apparatus.

rate research

Read More

110 - Z. Moss , L. Bugel , G. Collin 2014
Scintillation light produced in liquid argon (LAr) must be shifted from 128 nm to visible wavelengths in light detection systems used for liquid argon time-projection chambers (LArTPCs). To date, LArTPC light collection systems have employed tetraphenyl butadiene (TPB) coatings on photomultiplier tubes (PMTs) or plates placed in front of the PMTs. Recently, a new approach using TPB-coated light guides was proposed. In this paper, we report on light guides with improved attenuation lengths above 100 cm when measured in air. This is an important step in the development of meter-scale light guides for future LArTPCs. Improvements come from using a new acrylic-based coating, diamond-polished cast UV transmitting acrylic bars, and a hand-dipping technique to coat the bars. We discuss a model for connecting bar response in air to response in liquid argon and compare this to data taken in liquid argon. The good agreement between the prediction of the model and the measured response in liquid argon demonstrates that characterization in air is sufficient for quality control of bar production. This model can be used in simulations of light guides for future experiments.
The FlatDot detector has been used to demonstrate the separation of Cherenkov and scintillation light for 1 to 2MeV electrons in linear alkylbenzene (LAB). With an average PMT transit time spread (TTS) of 200ps, the early light in each event is clearly dominated by the Cherenkov signal, which on average comprises $86^{+2}_{-3}%$ of the light collected in the first 4.1ns of each event. The spatial distributions of the Cherenkov and scintillation light are found to match those predicted in Monte Carlo simulations. This is a key step towards demonstrating direction reconstruction of $beta$ decays, a technique that could reduce $^8$B solar neutrino backgrounds for neutrinoless double-beta decay experiments in liquid scintillator.
The search for neutrinoless double-beta decay (0{ u}{beta}{beta}) requires extremely low background and a good understanding of their sources and their influence on the rate in the region of parameter space relevant to the 0{ u}{beta}{beta} signal. We report on studies of various {beta}- and {gamma}-backgrounds in the liquid- xenon-based EXO-200 0{ u}{beta}{beta} experiment. With this work we try to better understand the location and strength of specific background sources and compare the conclusions to radioassay results taken before and during detector construction. Finally, we discuss the implications of these studies for EXO-200 as well as for the next-generation, tonne-scale nEXO detector.
128 - D. Gooding , J. Gruszko , C. Grant 2018
Liquid scintillators doped with metals are needed for a variety of measurements in nuclear and particle physics. Nanoparticles provide a mechanism to dope the scintillator and their unique optical properties could be used to enhance detection capabilities. We present here the first study of lead-based perovskite nanoparticles for this application. Perovskites are an attractive choice due to the versatility of their crystal structure and their ease of synthesis.
Precise calorimetric reconstruction of 5-50 MeV electrons in liquid argon time projection chambers (LArTPCs) will enable the study of astrophysical neutrinos in DUNE and could enhance the physics reach of oscillation analyses. Liquid argon scintillation light has the potential to improve energy reconstruction for low-energy electrons over charge-based measurements alone. Here we demonstrate light-augmented calorimetry for low-energy electrons in a single-phase LArTPC using a sample of Michel electrons from decays of stopping cosmic muons in the LArIAT experiment at Fermilab. Michel electron energy spectra are reconstructed using both a traditional charge-based approach as well as a more holistic approach that incorporates both charge and light. A maximum-likelihood fitter, using LArIATs well-tuned simulation, is developed for combining these quantities to achieve optimal energy resolution. A sample of isolated electrons is simulated to better determine the energy resolution expected for astrophysical electron-neutrino charged-current interaction final states. In LArIAT, which has very low wire noise and an average light yield of 18 pe/MeV, an energy resolution of $sigma/E simeq 9.3%/sqrt{E} oplus 1.3%$ is achieved. Samples are then generated with varying wire noise levels and light yields to gauge the impact of light-augmented calorimetry in larger LArTPCs. At a charge-readout signal-to-noise of S/N $simeq$ 30, for example, the energy resolution for electrons below 40 MeV is improved by $approx$ 10%, $approx$ 20%, and $approx$ 40% over charge-only calorimetry for average light yields of 10 pe/MeV, 20 pe/MeV, and 100 pe/MeV, respectively.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا