Do you want to publish a course? Click here

Linear Stability Analysis of a Levitated Nanomagnet in a Static Magnetic Field: Quantum Spin Stabilized Magnetic Levitation

134   0   0.0 ( 0 )
 Added by Cosimo C. Rusconi
 Publication date 2017
  fields Physics
and research's language is English




Ask ChatGPT about the research

We theoretically study the levitation of a single magnetic domain nanosphere in an external static magnetic field. We show that apart from the stability provided by the mechanical rotation of the nanomagnet (as in the classical Levitron), the quantum spin origin of its magnetization provides two additional mechanisms to stably levitate the system. Despite of the Earnshaw theorem, such stable phases are present even in the absence of mechanical rotation. For large magnetic fields, the Larmor precession of the quantum magnetic moment stabilizes the system in full analogy with magnetic trapping of a neutral atom. For low magnetic fields, the magnetic anisotropy stabilizes the system via the Einstein-de Haas effect. These results are obtained with a linear stability analysis of a single magnetic domain rigid nanosphere with uniaxial anisotropy in a Ioffe-Pritchard magnetic field.



rate research

Read More

We theoretically show that, despite Earnshaws theorem, a non-rotating single magnetic domain nanoparticle can be stably levitated in an external static magnetic field. The stabilization relies on the quantum spin origin of magnetization, namely the gyromagnetic effect. We predict the existence of two stable phases related to the Einstein--de Haas effect and the Larmor precession. At a stable point, we derive a quadratic Hamiltonian that describes the quantum fluctuations of the degrees of freedom of the system. We show that in the absence of thermal fluctuations, the quantum state of the nanomagnet at the equilibrium point contains entanglement and squeezing.
In the absence of dissipation a non-rotating magnetic nanoparticle can be stably levitated in a static magnetic field as a consequence of the spin origin of its magnetization. Here, we study the effects of dissipation on the stability of the system, considering the interaction with the background gas and the intrinsic Gilbert damping of magnetization dynamics. We find that dissipation limits the time over which a particle can be stably levitated. At large applied magnetic fields we identify magnetization switching induced by Gilbert damping as the key limiting factor for stable levitation. At low applied magnetic fields and for small particle dimensions magnetization switching is prevented due to the strong coupling of rotation and magnetization dynamics, and the stability is mainly limited by the gas-induced dissipation. In this latter case, high vacuum should be sufficient to extend stable levitation over experimentally relevant timescales. Our results demonstrate the possibility to experimentally observe the phenomenon of quantum spin stabilized magnetic levitation.
We present a protocol to achieve double quantum magnetometry at large static magnetic fields. This is a regime where sensitive sample parameters, such as the chemical shift, get enhanced facilitating their characterization. In particular, our method delivers two-tone stroboscopic radiation patterns with modulated Rabi frequencies to achieve larger spectral signals. Furthermore, it does not introduce inhomogeneous broadening in the sample spectrum preventing signal misinterpretation. Moreover, our protocol is designed to work under realistic conditions such as the presence of moderate microwave power and errors on the radiation fields. Albeit we particularise to nitrogen vacancy centers, our protocol is general, thus applicable to distinct quantum sensors.
74 - Rui Li , Fei Kong , Pengju Zhao 2020
The nitrogen-vacancy (NV) center is a potential atomic-scale spin sensor for electric field sensing. However, its natural susceptibility to the magnetic field hinders effective detection of the electric field. Here we propose a robust electrometric method utilizing continuous dynamic decoupling (CDD) technique. During the CDD period, the NV center evolves in a dressed-state space, where the sensor is resistant to magnetic fields but remains sensitive to electric fields. As an example, we use this method to isolate the electric noise from a complex electro-magnetical environment near diamond surface via measuring the dephasing rate between dressed states. By reducing the surface electric noise with different covered liquids, we observe an unambiguous relation between the dephasing rate and the dielectric permittivity of the liquid, which enables a quantitative investigation of electric noise model near diamond surface.
Current density distributions in active integrated circuits (ICs) result in patterns of magnetic fields that contain structural and functional information about the IC. Magnetic fields pass through standard materials used by the semiconductor industry and provide a powerful means to fingerprint IC activity for security and failure analysis applications. Here, we demonstrate high spatial resolution, wide field-of-view, vector magnetic field imaging of static (DC) magnetic field emanations from an IC in different active states using a Quantum Diamond Microscope (QDM). The QDM employs a dense layer of fluorescent nitrogen-vacancy (NV) quantum defects near the surface of a transparent diamond substrate placed on the IC to image magnetic fields. We show that QDM imaging achieves simultaneous $sim10$ $mu$m resolution of all three vector magnetic field components over the 3.7 mm $times$ 3.7 mm field-of-view of the diamond. We study activity arising from spatially-dependent current flow in both intact and decapsulated field-programmable gate arrays (FPGAs); and find that QDM images can determine pre-programmed IC active states with high fidelity using machine-learning classification methods.
comments
Fetching comments Fetching comments
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا