Plastic scintillation detectors for Time-of-Flight (TOF) measurements are almost essential for event-by-event identification of relativistic rare isotopes. In this work, a pair of plastic scintillation detectors of 50 $times$ 50 $times$ 3$^{t}$ mm$^3$ and 80 $times$ 100 $times$ 3$^{t}$ mm$^3$ have been set up at the external target facility (ETF), Institute of Modern Physics. Their time, energy and position responses are measured with $^{18}$O primary beam at 400 MeV/nucleon. After the off-line walk-effect and position corrections, the time resolution of the two detectors are determined to be 27 ps ($sigma$) and 36 ps ($sigma$), respectively. Both detectors have nearly the same energy resolution of 3$%$ ($sigma$) and position resolution of 2 mm ($sigma$). The detectors have been used successfully in nuclear reaction cross section measurements, and will be be employed for upgrading RIBLL2 beam line at IMP as well as for the high energy branch at HIAF.
Timing-pick up detectors with excellent timing resolutions are essential in many modern nuclear physics experiments. Aiming to develop a Time-Of-Flight system with precision down to about 10 ps, we have made a systematic study of the timing characteristic of TOF detectors, which consist of several combinations of plastic scintillators and photomultiplier tubes. With the conventional electronics, the best timing resolution of about 5.1 ps ({sigma}) has been achieved for detectors with an area size of 3x1 cm2. It is found that for data digitalization a combination of TAC and ADC can achieve a better time resolution than currently available TDC. Simultaneously measurements of both time and pulse height are very valuable for correction of time-walk effect.
The detection of 200-1000 MeV neutrons requires large amounts, $sim$100 cm, of detector material because of the long nuclear interaction length of these particles. In the example of the NeuLAND neutron time-of-flight detector at FAIR, this is accomplished by using 3000 monolithic scintillator bars of 270$times$5$times$5 cm$^3$ size made of a fast plastic. Each bar is read out on the two long ends, and the needed time resolution of $sigma_t$ $<$ 150 ps is reached with fast timing photomultipliers. In the present work, it is investigated whether silicon photomultiplier (SiPM) photosensors can be used instead. Experiments with a picosecond laser system were conducted to determine the timing response of the assembly made up of SiPM and preamplifier. The response of the full system including also the scintillator was studied using 30 MeV single electrons provided by the ELBE superconducting electron linac. The ELBE data were matched by a simple Monte Carlo simulation, and they were found to obey an inverse-square-root scaling law. In the electron beam tests, a time resolution of $sigma_t$ = 136 ps was reached with a pure SiPM readout, well within the design parameters for NeuLAND.
In typical nuclear physics experiments with radioactive ion beams (RIBs) selected by the in-flight separation technique, Si detectors or ionization chambers are usually equipped for the charge determination of RIBs. The obtained charge resolution relies on the performance of these detectors for energy loss determination, and this affects the particle identification capability of RIBs. We present an approach on improving the resolution of charge measurement for heavy ions by using the abundant energy loss information from different types of existing detectors along the beam line. Without altering the beam line and detectors, this approach can improve the charge resolution by more than 12% relative to the multiple sampling ionization chamber of the best resolution.
The general properties needed in targets (sources) for high precision, high accuracy measurements are reviewed. The application of these principles to the problem of developing targets for the Fission TPC is described. Longer term issues, such as the availability of actinide materials, improved knowledge of energy losses and straggling and the stability of targets during irradiation are also discussed.
A new timing detector measuring ~50 MeV/c positrons is under development for the MEG II experiment, aiming at a time resolution $sigma_t sim 30~mathrm{ps}$. The resolution is expected to be achieved by measuring each positron time with multiple counters made of plastic scintillator readout by silicon photomultipliers (SiPMs). The purpose of this work is to demonstrate the time resolution for ~50 MeV/c positrons using prototype counters. Counters with dimensions of $90times 40times 5~mathrm{mm}^3$ readout by six SiPMs (three on each $40times 5~mathrm{mm}^2$ plane) were built with SiPMs from Hamamatsu Photonics and AdvanSiD and tested in a positron beam at the DA$Phi$NE Beam Test Facility. The time resolution was found to improve nearly as the square root of the number of counter hits. A time resolution $sigma_t=26.2pm1.3~mathrm{ps}$ was obtained with eight counters with Hamamatsu SiPMs. These results suggest that the design resolution is achievable in the MEG II experiment.