Do you want to publish a course? Click here

The General Single-Dish Data Format: A Retrospective

145   0   0.0 ( 0 )
 Added by Tim Jenness
 Publication date 2015
  fields Physics
and research's language is English




Ask ChatGPT about the research

The General Single-Dish Data format (GSDD) was developed in the mid-1980s as a data model to support centimeter, millimeter and submillimeter instrumentation at NRAO, JCMT, the University of Arizona and IRAM. We provide an overview of the GSDD requirements and associated data model, discuss the implementation of the resultant file formats, describe its usage in the observatories and provide a retrospective on the format.



rate research

Read More

The Virtual Observatory (VO) is becoming the de-facto standard for astronomical data publication. However, the number of radio astronomical archives is still low in general, and even lower is the number of radio astronomical data available through the VO. In order to facilitate the building of new radio astronomical archives, easing at the same time their interoperability with VO framework, we have developed a VO-compliant data model which provides interoperable data semantics for radio data. That model, which we call the Radio Astronomical DAta Model for Single-dish (RADAMS) has been built using standards of (and recommendations from) the International Virtual Observatory Alliance (IVOA). This article describes the RADAMS and its components, including archived entities and their relationships to VO metadata. We show that by using IVOA principles and concepts, the effort needed for both the development of the archives and their VO compatibility has been lowered, and the joint development of two radio astronomical archives have been possible. We plan to adapt RADAMS to be able to deal with interferometry data in the future.
For submillimeter spectroscopy with ground-based single-dish telescopes, removing noise contribution from the Earths atmosphere and the instrument is essential. For this purpose, here we propose a new method based on a data-scientific approach. The key technique is statistical matrix decomposition that automatically separates the signals of astronomical emission lines from the drift noise components in the fast-sampled (1--10 Hz) time-series spectra obtained by a position-switching (PSW) observation. Because the proposed method does not apply subtraction between two sets of noisy data (i.e., on-source and off-source spectra), it improves the observation sensitivity by a factor of $sqrt{2}$. It also reduces artificial signals such as baseline ripples on a spectrum, which may also help to improve the effective sensitivity. We demonstrate this improvement by using the spectroscopic data of emission lines toward a high-redshift galaxy observed with a 2-mm receiver on the 50-m Large Millimeter Telescope (LMT). Since the proposed method is carried out offline and no additional measurements are required, it offers an instant improvement on the spectra reduced so far with the conventional method. It also enables efficient deep spectroscopy driven by the future 50-m class large submillimeter single-dish telescopes, where fast PSW observations by mechanical antenna or mirror drive are difficult to achieve.
142 - E. Cenacchi , A. Kraus , A. Orfei 2009
The study of the linear and circular polarization in AGN allows one to gain detailed information about the properties of the magnetic fields in these objects. However, especially the observation of circular polarization (CP) with single-dish radio-telescopes is usually difficult because of the weak signals to be expected. Normally CP is derived as the (small) difference of two large numbers (LHC and RHC); hence an accurate calibration is absolutely necessary. Our aim is to improve the calibration accuracy to include the Stokes parameter V in the common single-dish polarimetric measurements, allowing a full Stokes study of the source under examination. A detailed study, up to the 2nd order, of the Mueller matrix elements in terms of cross-talk components allows us to reach the accuracy necessary to study circular polarization. The new calibration method has been applied to data taken at the 100-m Effelsberg radio-telescope during regular test observations of extragalactic sources at 2.8, 3.6, 6 and 11 cm. The D-terms in phase and amplitude appear very stable with time and the few known values of circular polarization have been confirmed. It is shown that, whenever a classical receiver and a multiplying polarimeter are available, the proposed calibration scheme allows one to include Stokes V in standard single-dish polarimetric observations as difference of two native circular outputs.
Imaging in radio astronomy is usually carried out with a single-dish radio telescope doing a raster scan of a region of the sky or with an interferometer that samples the visibility function of the sky brightness. Mosaic observations are the current standard for imaging large fields of view with an interferometer and multi-frequency observations are now routinely carried out with both types of telescopes to increase the continuum imaging sensitivity and to probe spectral structure. This paper describes an algorithm to combine wideband data from these two types of telescopes in a joint iterative reconstruction scheme that can be applied to spectral cube or wideband multi-term imaging both for narrow fields of view as well as mosaics. Our results demonstrate the ability to prevent instabilities and error that typically arise when wide-band or joint mosaicing algorithms are presented with spatial and spectral structure that is inadequetely sampled by the interferometer alone. For comparable noise levels in the single dish and interferometer data, the numerical behaviour of this algorithm is expected to be similar to the idea of generating artificial visibilities from single dish data. However, our discussed implementation is simpler and more flexible in terms of applying relative data weighting schemes to match noise levels while preserving flux accuracy, fits within standard iterative image reconstruction frameworks, is fully compatible with wide-field and joint mosaicing gridding algorithms that apply corrections specific to the interferometer data and may be configured to enable spectral cube and wideband multi-term deconvolution for single-dish data alone.
We discuss the detection of large scale HI intensity fluctuations using a single dish approach with the ultimate objective of measuring the Baryonic Acoustic Oscillations and constraining the properties of dark energy. We present 3D power spectra, 2D angular power spectra for individual redshift slices, and also individual line-of-sight spectra, computed using the S^3 simulated HI catalogue which is based on the Millennium Simulation. We consider optimal instrument design and survey strategies for a single dish observation at low and high redshift for a fixed sensitivity. For a survey corresponding to an instrument with T_sys=50 K, 50 feed horns and 1 year of observations, we find that at low redshift (z approx 0.3), a resolution of 40 arc min and a survey of 5000 deg^2 is close to optimal, whereas at higher redshift (z approx 0.9) a resolution of 10 arcmin and 500 deg^2 would be necessary. Continuum foreground emission from the Galaxy and extragalactic radio sources are potentially a problem. We suggest that it could be that the dominant extragalactic foreground comes from the clustering of very weak sources. We assess its amplitude and discuss ways by which it might be mitigated. We then introduce our concept for a single dish telescope designed to detect BAO at low redshifts. It involves an under-illumintated static 40 m dish and a 60 element receiver array held 90 m above the under-illuminated dish. Correlation receivers will be used with each main science beam referenced against an antenna pointing at one of the Celestial Poles for stability and control of systematics. We make sensitivity estimates for our proposed system and projections for the uncertainties on the power spectrum after 1 year of observations. We find that it is possible to measure the acoustic scale at zapprox 0.3 with an accuracy 2.4% and that w can be measured to an accuracy of 16%.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا