Do you want to publish a course? Click here

Simultaneous Multi-band Radio & X-ray Observations of the Galactic Center Magnetar SGR 1745$-$2900

485   0   0.0 ( 0 )
 Added by Timothy Pennucci
 Publication date 2015
  fields Physics
and research's language is English




Ask ChatGPT about the research

We report on multi-frequency, wideband radio observations of the Galactic Center magnetar (SGR 1745$-$2900) with the Green Bank Telescope for $sim$100 days immediately following its initial X-ray outburst in April 2013. We made multiple simultaneous observations at 1.5, 2.0, and 8.9 GHz, allowing us to examine the magnetars flux evolution, radio spectrum, and interstellar medium parameters (such as the dispersion measure (DM), the scattering timescale and its index). During two epochs, we have simultaneous observations from the Chandra X-ray Observatory, which permitted the absolute alignment of the radio and X-ray profiles. As with the two other radio magnetars with published alignments, the radio profile lies within the broad peak of the X-ray profile, preceding the X-ray profile maximum by $sim$0.2 rotations. We also find that the radio spectral index $gamma$ is significantly negative between $sim$2 and 9 GHz; during the final $sim$30 days of our observations $gamma sim -1.4$, which is typical of canonical pulsars. The radio flux has not decreased during this outburst, whereas the long-term trends in the other radio magnetars show concomitant fading of the radio and X-ray fluxes. Finally, our wideband measurements of the DMs taken in adjacent frequency bands in tandem are stochastically inconsistent with one another. Based on recent theoretical predictions, we consider the possibility that the dispersion measure is frequency-dependent. Despite having several properties in common with the other radio magnetars, such as $L_{textrm{X,qui}}/L_{textrm{rot}} lesssim 1$, an increase in the radio flux during the X-ray flux decay has not been observed thus far in other systems.



rate research

Read More

We report on simultaneous observations of the magnetar SGR J1745-2900 at frequencies $ u = 2.54$ to $225,rm{GHz}$ using the Nancay 94-m equivalent, Effelsberg 100-m, and IRAM 30-m radio telescopes. We detect SGR J1745-2900 up to 225 GHz, the highest radio frequency detection of pulsed emission from a neutron star to date. Strong single pulses are also observed from 4.85 up to 154 GHz. At the millimetre band we see significant flux density and spectral index variabilities on time scales of tens of minutes, plus variability between days at all frequencies. Additionally, SGR J1745-2900 was observed at a different epoch at frequencies 296 to 472 GHz using the APEX 12-m radio telescope, with no detections. Over the period MJD 56859.83-56862.93 the fitted spectrum yields a spectral index of $left<alpharight> = -0.4 pm 0.1$ for a reference flux density $left< S_{154} right> = 1.1 pm 0.2rm{,mJy}$ (with $S_{ u} propto { u}^{alpha})$, a flat spectrum alike those of the other radio-loud magnetars. These results show that strongly magnetized neutron stars can be effective radio emitters at frequencies notably higher to what was previously known and that pulsar searches in the Galactic Centre are possible in the millimetre band.
We present the X-ray timing and spectral evolution of the Galactic Center magnetar SGR J1745-2900 for the first ~4 months post-discovery using data obtained with the Nuclear Spectroscopic Telescope Array (NuSTAR)} and Swift observatories. Our timing analysis reveals a large increase in the magnetar spin-down rate by a factor of 2.60 +/- 0.07 over our data span. We further show that the change in spin evolution was likely coincident with a bright X-ray burst observed in 2013 June by Swift, and if so, there was no accompanying discontinuity in the frequency. We find that the source 3-10 keV flux has declined monotonically by a factor of ~2 over an 80-day period post-outburst accompanied by a ~20% decrease in the sources blackbody temperature, although there is evidence for both flux and kT having levelled off. We argue that the torque variations are likely to be magnetospheric in nature and will dominate over any dynamical signatures of orbital motion around Sgr A*.
83 - W. M. Yan 2018
We report on single-pulse observations of the Galactic Center magnetar PSR J1745$-$2900 that were made using the Parkes 64-m radio telescope with a central frequency of 3.1 GHz at five observing epochs between 2013 July and August. The shape of the integrated pulse profiles was relatively stable across the five observations, indicating that the pulsar was in a stable state between MJDs 56475 and 56514. This extends the known stable state of this pulsar to 6.8 months. Short term pulse shape variations were also detected. It is shown that this pulsar switches between two emission modes frequently and that the typical duration of each mode is about ten minutes. No giant pulses or subpulse drifting were observed. Apparent nulls in the pulse emission were detected on MJD 56500. Although there are many differences between the radio emission of magnetars and normal radio pulsars, they also share some properties. The detection of mode changing and pulse nulling in PSR J1745$-$2900 suggests that the basic radio emission process for magnetars and normal pulsars is the same.
We present radio continuum light curves of the magnetar SGR J1745$-$2900 and Sgr A* obtained with multi-frequency, multi-epoch Very Large Array observations between 2012 and 2014. During this period, a powerful X-ray outburst from SGR J1745$-$2900 occurred on 2013-04-24. Enhanced radio emission is delayed with respect to the X-ray peak by about seven months. In addition, the flux density of the emission from the magnetar fluctuates by a factor of 2 to 4 at frequencies between 21 and 41 GHz and its spectral index varies erratically. Here we argue that the excess fluctuating emission from the magnetar arises from the interaction of a shock generated from the X-ray outburst with the orbiting ionized gas at the Galactic center. In this picture, variable synchrotron emission is produced by ram pressure variations due to inhomogeneities in the dense ionized medium of the Sgr A West bar. The pulsar with its high transverse velocity is moving through a highly blue-shifted ionized medium. This implies that the magnetar is at a projected distance of $sim0.1$ pc from Sgr A* and that the orbiting ionized gas is partially or largely responsible for a large rotation measure detected toward the magnetar. Despite the variability of Sgr A* expected to be induced by the passage of the G2 cloud, monitoring data shows a constant flux density and spectral index during this period
The magnetar SGR J1745-2900 discovered at parsecs distance from the Milky Way central black hole, Sagittarius A*, represents the closest pulsar to a supermassive black hole ever detected. Furthermore, its intriguing radio emission has been used to study the environment of the black hole, as well as to derive a precise position and proper motion for this object. The discovery of SGR J1745-2900 has opened interesting debates about the number, age and nature of pulsars expected in the Galactic center region. In this work, we present extensive X-ray monitoring of the outburst of SGR J1745-2900 using the Chandra X-ray Observatory, the only instrument with the spatial resolution to distinguish the magnetar from the supermassive black hole (2.4 angular distance). It was monitored from its outburst onset in April 2013 until August 2019, collecting more than fifty Chandra observations for a total of more than 2.3 Ms of data. Soon after the outburst onset, the magnetar emission settled onto a purely thermal emission state that cooled from a temperature of about 0.9 to 0.6 keV over 6 years. The pulsar timing properties showed at least two changes in the period derivative, increasing by a factor of about 4 during the outburst decay. We find that the long-term properties of this outburst challenge current models for the magnetar outbursts.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا