Do you want to publish a course? Click here

Performance of the Charge Injection Capability of Suzaku XIS

123   0   0.0 ( 0 )
 Added by Hiroshi Nakajima
 Publication date 2007
  fields Physics
and research's language is English




Ask ChatGPT about the research

A charge injection technique is applied to the X-ray CCD camera, XIS (X-ray Imaging Spectrometer) onboard Suzaku. The charge transfer inefficiency (CTI) in each CCD column (vertical transfer channel) is measured by the injection of charge packets into a transfer channel and subsequent readout. This paper reports the performances of the charge injection capability based on the ground experiments using a radiation damaged device, and in-orbit measurements of the XIS. The ground experiments show that charges are stably injected with the dispersion of 91eV in FWHM in a specific column for the charges equivalent to the X-ray energy of 5.1keV. This dispersion width is significantly smaller than that of the X-ray events of 113eV (FWHM) at approximately the same energy. The amount of charge loss during transfer in a specific column, which is measured with the charge injection capability, is consistent with that measured with the calibration source. These results indicate that the charge injection technique can accurately measure column-dependent charge losses rather than the calibration sources. The column-to-column CTI correction to the calibration source spectra significantly reduces the line widths compared to those with a column-averaged CTI correction (from 193eV to 173eV in FWHM on an average at the time of one year after the launch). In addition, this method significantly reduces the low energy tail in the line profile of the calibration source spectrum.



rate research

Read More

We present the result of a systematic study of pileup phenomena seen in the X-ray Imaging Spectrometer, an X-ray CCD instrument, onboard the Suzaku observatory. Using a data set of observed sources in a wide range of brightness and spectral hardness, we characterized the pileup fraction, spectral hardening, and grade migration as a function of observed count rate in a frame per pixel. Using the pileup fraction as a measure of the degree of pileup, we found that the relative spectral hardening (the hardness ratio normalized to the intrinsic spectral hardness), branching ratio of split events, and that of detached events increase monotonically as the pileup fraction increases, despite the variety of brightness and hardness of the sample sources. We derived the pileup fraction as a function of radius used for event extraction. Upon practical considerations, we found that events outside of the radius with a pileup fraction of 1% or 3% are useful for spectral analysis. We present relevant figures, tables, and software for the convenience of users who wish to apply our method for their data reduction of piled-up sources.
The charge transfer inefficiency (CTI) of the X-ray CCDs on board the Suzaku satellite (X-ray Imaging Spectrometers; XIS) has increased since the launch due to radiation damage, and the energy resolution has been degraded. To improve the CTI, we have applied a spaced-row charge injection (SCI) technique to the XIS in orbit; by injecting charges into CCD rows periodically, the CTI is actively decreased. The CTI in the SCI mode depends on the distance between a signal charge and a preceding injected row, and the pulse height shows periodic positional variations. Using in-flight data of onboard calibration sources and of the strong iron line from the Perseus cluster of galaxies, we studied the variation in detail. We developed a new method to correct the variation. By applying the new method, the energy resolution (FWHM) at 5.9 keV at March 2008 is ~155 eV for the front-illuminated CCDs and ~175 eV for the back-illuminated CCD.
The X-ray Imaging Spectrometer (XIS) on board the Suzaku satellite is an X-ray CCD camera system that has superior performance such as a low background, high quantum efficiency, and good energy resolution in the 0.2-12 keV band. Because of the radiation damage in orbit, however, the charge transfer inefficiency (CTI) has increased, and hence the energy scale and resolution of the XIS has been degraded since the launch of July 2005. The CCD has a charge injection structure, and the CTI of each column and the pulse-height dependence of the CTI are precisely measured by a checker flag charge injection (CFCI) technique. Our precise CTI correction improved the energy resolution from 230 eV to 190 eV at 5.9 keV in December 2006. This paper reports the CTI measurements with the CFCI experiments in orbit. Using the CFCI results, we have implemented the time-dependent energy scale and resolution to the Suzaku calibration database.
We have developed a framework for the Monte-Carlo simulation of the X-Ray Telescopes (XRT) and the X-ray Imaging Spectrometers (XIS) onboard Suzaku, mainly for the scientific analysis of spatially and spectroscopically complex celestial sources. A photon-by-photon instrumental simulator is built on the ANL platform, which has been successfully used in ASCA data analysis. The simulator has a modular structure, in which the XRT simulation is based on a ray-tracing library, while the XIS simulation utilizes a spectral Redistribution Matrix File (RMF), generated separately by other tools. Instrumental characteristics and calibration results, e.g., XRT geometry, reflectivity, mutual alignments, thermal shield transmission, build-up of the contamination on the XIS optical blocking filters (OBF), are incorporated as completely as possible. Most of this information is available in the form of the FITS (Flexible Image Transport System) files in the standard calibration database (CALDB). This simulator can also be utilized to generate an Ancillary Response File (ARF), which describes the XRT response and the amount of OBF contamination. The ARF is dependent on the spatial distribution of the celestial target and the photon accumulation region on the detector, as well as observing conditions such as the observation date and satellite attitude. We describe principles of the simulator and the ARF generator, and demonstrate their performance in comparison with in-flight data.
A fleet of nanosatellites using precise timing synchronization provided by the Global Positioning System is a new concept for monitoring the gamma-ray sky that can achieve both all-sky coverage and good localization accuracy. We are proposing this new concept for the mission CubeSats Applied for MEasuring and LOcalising Transients (CAMELOT). The differences in photon arrival times at each satellite are to be used for source localization. Detectors with good photon statistics and the development of a localization algorithm capable of handling a large number of satellites are both essential for this mission. Large, thin CsI scintillator plates are the current candidates for the detectors because of their high light yields. It is challenging to maximize the light-collection efficiency and to understand the position dependence of such thin plates. We have found a multi-channel readout that uses the coincidence technique to be very effective in increasing the light output while keeping a similar noise level to that of a single channel readout. Based on such a detector design, we have developed a localization algorithm for this mission and have found that we can achieve a localization accuracy better than 20 arc minutes and a rate of about 10 short gamma-ray bursts per year.
comments
Fetching comments Fetching comments
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا