Do you want to publish a course? Click here

The CAST Time Projection Chamber

63   0   0.0 ( 0 )
 Added by Markus Kuster
 Publication date 2007
  fields Physics
and research's language is English
 Authors D. Autiero




Ask ChatGPT about the research

One of the three X-ray detectors of the CAST experiment searching for solar axions is a Time Projection Chamber (TPC) with a multi-wire proportional counter (MWPC) as a readout structure. Its design has been optimized to provide high sensitivity to the detection of the low intensity X-ray signal expected in the CAST experiment. A low hardware threshold of 0.8 keV is safely set during normal data taking periods, and the overall efficiency for the detection of photons coming from conversion of solar axions is 62 %. Shielding has been installed around the detector, lowering the background level to 4.10 x 10^-5 counts/cm^2/s/keV between 1 and 10 keV. During phase I of the CAST experiment the TPC has provided robust and stable operation, thus contributing with a competitive result to the overall CAST limit on axion-photon coupling and mass.



rate research

Read More

In this paper we give a thorough description of a liquid argon time projection chamber designed, built and operated at Yale. We present results from a calibration run where cosmic rays have been observed in the detector, a first in the US.
119 - J. Barney , J. Estee , W.G. Lynch 2020
The SAMURAI Pion Reconstruction and Ion-Tracker Time Projection Chamber (S$pi$RIT TPC) was designed to enable measurements of heavy ion collisions with the SAMURAI spectrometer at the RIKEN Radioactive Isotope Beam Factory and provide constraints on the Equation of State of neutron-rich nuclear matter. The S$pi$RIT TPC has a 50.5 cm drift length and an 86.4 cm $times$ 134.4 cm pad plane with 12,096 pads that are equipped with the Generic Electronics for TPCs readout electronics. The S$pi$RIT TPC allows excellent reconstruction of particles and provides isotopic resolution for pions and other light charged particles across a wide range of energy losses and momenta. Details of the S$pi$RIT TPC are presented, along with discussion of the TPC performance based on cosmic ray and experimental data.
This manuscript describes the commissioning of the Mini-CAPTAIN liquid argon detector in a neutron beam at the Los Alamos Neutron Science Center (LANSCE), which led to a first measurement of high-energy neutron interactions in argon. The Mini-CAPTAIN detector consists of a Time Projection Chamber (TPC) with an accompanying photomultiplier tube (PMT) array sealed inside a liquid-argon-filled cryostat. The liquid argon is constantly purified and recirculated in a closed-loop cycle during operation. The specifications and assembly of the detector subsystems and an overview of their performance in a neutron beam are reported.
176 - M. Ball 2012
This document illustrates the technical layout and the expected performance of a Time Projection Chamber as the central tracking system of the PANDA experiment. The detector is based on a continuously operating TPC with Gas Electron Multiplier (GEM) amplification.
For the International Large Detector concept at the planned International Linear Collider, the use of time projection chambers (TPC) with micro-pattern gas detector readout as the main tracking detector is investigated. In this paper, results from a prototype TPC, placed in a 1 T solenoidal field and read out with three independent GEM-based readout modules, are reported. The TPC was exposed to a 6 GeV electron beam at the DESY II synchrotron. The efficiency for reconstructing hits, the measurement of the drift velocity, the space point resolution and the control of field inhomogeneities are presented.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا