Pulse Shape Discrimination in the IGEX Experiment

70   0   0.0 ( 0 )
 Added by Susana Cebrian
 Publication date 2003
  fields
and research's language is English




Ask ChatGPT about the research

The IGEX experiment has been operating enriched germanium detectors in the Canfranc Underground Laboratory (Spain) in a search for the neutrinoless double decay of 76Ge. The implementation of Pulse Shape Discrimination techniques to reduce the radioactive background is described in detail. This analysis has been applied to a fraction of the IGEX data, leading to a rejection of ~60 % of their background, in the region of interest (from 2 to 2.5 MeV), down to ~0.09 c/(keV kg y).



rate research

Read More

Events near the cathode and anode surfaces of a coplanar grid CdZnTe detector are identifiable by means of the interaction depth information encoded in the signal amplitudes. However, the amplitudes cannot be used to identify events near the lateral surfaces. In this paper a method is described to identify lateral surface events by means of their pulse shapes. Such identification allows for discrimination of surface alpha particle interactions from more penetrating forms of radiation, which is particularly important for rare event searches. The effectiveness of the presented technique in suppressing backgrounds due to alpha contamination in the search for neutrinoless double beta decay with the COBRA experiment is demonstrated.
171 - L.Bardelli , M.Bini , P.G.Bizzeti 2007
The light output, $alpha/beta$ ratio, and pulse shape have been investigated at $-25^circ$ C with PbWO$_4$ crystal scintillators undoped, and doped by F, Eu, Mo, Gd and S. The fast $0.01-0.06 mu$s and middle $0.1-0.5 mu$s components of scintillation decay were observed for all the samples. Slow components of scintillation signal with the decay times $1-3 mu$s and $13-28 mu$s with the total intensity up to $approx50%$ have been recognized for several samples doped by Molybdenum. We found some indications of a pulse-shape discrimination between $alpha$ particles and $gamma$ quanta with PbWO$_4$ (Mo doped) crystal scintillators.
127 - S. A. Hertel , M. Pyle 2011
SuperCDMS is the next phase of the Cryogenic Dark Matter Search experiment, which measures both phonon and charge signals generated by particle recoils within a germanium target mass. Charge signals are employed both in the definition of a fiducial volume and in the rejection of electron recoil background events. Alternatively, phonons generated by the charge carriers can also be used for the same two goals. This paper describes preliminary efforts to observe and quantify these contributions to the phonon signal and then use them to reject background events. A simple analysis using only one pulse shape parameter shows bulk electron recoil vs. bulk nuclear recoil discrimination to the level of 1:10^3 (limited by the statistics of the data), with little degradation in discrimination ability down to at least 7 keV recoil energy. Such phonon-only discrimination can provide a useful cross-check to the standard discrimination methods, and it also points towards the potential of a device optimized for a phonon-only measurement.
145 - S. Oguri , Y. Inoue , M. Minowa 2010
We measured the decay time of the scintillation pulses produced by electron and nuclear recoils in CaF2(Eu) by a new fitting method. In the recoil energy region 5-30 keVee, we found differences of the decay time between electron and nuclear recoil events. In the recoil energy region above 20 keVee, we found that the decay time is independent of the recoil energy.
Discrimination of the detection of fast neutrons and gamma rays in a liquid scintillator detector has been investigated using digital pulse-processing techniques. An experimental setup with a 252Cf source, a BC-501 liquid scintillator detector, and a BaF2 detector was used to collect waveforms with a 100 Ms/s, 14 bit sampling ADC. Three identical ADCs were combined to increase the sampling frequency to 300 Ms/s. Four different digital pulse-shape analysis algorithms were developed and compared to each other and to data obtained with an analogue neutron-gamma discrimination unit. Two of the digital algorithms were based on the charge comparison method, while the analogue unit and the other two digital algorithms were based on the zero-crossover method. Two different figure-of-merit parameters, which quantify the neutron-gamma discrimination properties, were evaluated for all four digital algorithms and for the analogue data set. All of the digital algorithms gave similar or better figure-of-merit values than what was obtained with the analogue setup. A detailed study of the discrimination properties as a function of sampling frequency and bit resolution of the ADC was performed. It was shown that a sampling ADC with a bit resolution of 12 bits and a sampling frequency of 100 Ms/s is adequate for achieving an optimal neutron-gamma discrimination for pulses having a dynamic range for deposited neutron energies of 0.3-12 MeV. An investigation of the influence of the sampling frequency on the time resolution was made. A FWHM of 1.7 ns was obtained at 100 Ms/s.