Do you want to publish a course? Click here

Very large Magneto-impedance and its scaling behavior in amorphous Fe73.5Nb3Cu1Si13.5B9 ribbon

94   0   0.0 ( 0 )
 Added by Bhaskar Kaviraj Mr.
 Publication date 2006
  fields Physics
and research's language is English




Ask ChatGPT about the research

Magneto-impedance (MI) effects have been observed for amorphous Fe73.5Nb3Cu1Si13.5B9 ribbon which has been excited by an a.c. magnetic field parallel to the length of the ribbon. Maximum relative change in MI as large as -99% was observed which has never been reported before. The relative change in MI, when plotted against scaled field was found to be nearly frequency independent. A phenomenological formula for magneto-impedance, Z(H), in a ferromagnetic material, is proposed based on Pade approximant to describe the scaled behavior of MI.



rate research

Read More

45 - B. Kaviraj , S.K. Ghatak 2006
The magneto-impedance (MI) in amorphous ribbon of nominal composition Fe73.5Nb3Cu1Si13.5B9 has been measured at 1MHz and at room temperature for different configurations of exciting a.c and biasing d.c. fields. A large drop in both resistance and reactance is observed as a function of d.c magnetic field. When the d.c and a.c fields are parallel but normal to the axis of ribbon, smaller magnetic field is needed to reduce the impedance to its small saturated value compared to the situation when fields are along the axis of ribbon. Larger d.c. field is required to lower the impedance when the d.c field acts perpendicular to the plane of the ribbon. Such anisotropy in magneto-impedance is related to the anisotropic response of the magnetization of ribbon. The large change of impedance is attributed to large variation of a.c permeability on the direction and magnitude of the dc biasing field.
104 - B. Kaviraj , S. K. Ghatak 2006
Systematic measurements of stress impedance (SI) and magneto-impedance (MI) have been carried out using Co-rich amorphous ribbons of nominal composition Co71-xFexCr7Si8B14 (x = 0, 2) at various excitation frequencies and bias fields and at room temperature. The impedance, Z, for both the samples was found to be very sensitive functions of applied tensile stress (up to 100MPa) exhibiting a maximum SI ratio as much as 80% at low frequency ~ 0.1MHz. The nature of variation of impedance, Z, changes with the excitation frequency especially at higher frequencies in MHz region where it exhibits a peak. Magnetization measurements were also performed to observe the effects of applied stress and magnetization decreases with the application of stress confirming the negative magnetostriction co-efficient of both the samples. Both the samples exhibited negative magneto-impedance when the variation of Z is observed with the applied bias magnetic field, H. Maximum MI ratio as large as 99% has been observed for both the samples at low fields ~ 27Oe. The impedance as functions of applied magnetic field, Z(H), decreases with the application of stress thus making the MI curves broader. Based on the electromagnetic screening and magnetization dynamics and incorporating the Gilbert and the Bloch-Bloembergen damping and stress dependent anisotropy, the SI has been calculated and is found to describe well the stress and field dependence of impedance of the two samples.
Representation of dielectric properties by impedance spectroscopy (IS) is analyzed carefully in this paper. It is found that IS is not a good tool to describe a uniform system because a pseudo relaxation peaks exists at low frequency limit corresponding to direct current (DC) conductivity and two relaxation peaks appears simultaneously corresponding to one relaxation process for a high loss system with tand>1. However it is very convenient to describe a multiple phase system with IS. When dielectric properties are shown by Cole-Cole equation, only one Cole-Cole arc appears for one phase in IS, therefore it is very easy to distinguish different phases from each other. Especially, since pseudo relaxation exists at low frequency limit for each phase, the location of a certain relaxation process can be deduced by IS without any uncertainty. Furthermore, when dielectric properties are shown with specific impedance spectroscopy (ISI), the information of microstructure can be obtained conveniently. Based on the theoretical results above, dielectric properties of CaCu3Ti4O12 (CCTO) ceramics with giant dielectric constant (GDC) are investigated. Microstructure of CCTO is obtained by dielectric spectrometer and the origin of GDC is found to come from pseudo relaxation of grain.
The resistive and reactive parts of the magneto-impedance of sintered ferromagnetic samples of La0.7Sr0.3-xAgxMnO3 (x = 0.05, 0.25) have been measured at room temperature (<Tc) over frequency interval 1KHz to 15MHz and in presence of magnetic field up to 4KOe. The field dependence of relative change in resistance is small in KHz region but increases strongly for higher frequency of excitation. The maximum value of relative change in resistance at H =4KOe was found to be around 70% at 15MHz frequency.On the contrary the corresponding change in reactance has less frequency sensitivity and the maximum occurs at 1MHz frequency. The magneto-impedance is negative for all frequencies. The normalized magneto-impedance as defined by [Z(H)-Z(0)]/[Z(0)-Z(4K)] when plotted against scaled field H/H1/2 is found to be frequency independent ; H1/2 is the field where normalized magneto-impedance is reduced to half its maximum. A phenomenological formula for magneto-impedance Z (H) in ferromagnetic material is proposed based on Pade approximant. The formula for Z (H) predicts the scaled behavior of normalized magneto-impedance.
127 - B. Kaviraj , S. K. Ghatak 2006
A two-core transducer assembly using a Fe73.5Nb3Cu1Si13.5B9 ribbon to detect a change of magnetic field is proposed and tested for displacement (linear and angular) and current sensor. Two identical inductors, with the ribbon as core, are a part of two series resonance network, and are in high impedance state when excited by a small a.c field of 1MHz in absence of d.c biasing field (Hdc). When the magnetic state of one inductor is altered by biasing field, produced by a bar magnet or current carrying coil, an ac signal proportional to Hdc is generated by transducer. The results for the sensitivity and linearity with displacement (linear and angular) of a magnet and with field from the current carrying coil are presented for two particular configurations of the transducer. High sensitivities of voltage response as much as 12micro-volt/micro-meter and 3mV/degree have been obtained for the transducer as a linear and angular displacement sensor respectively in the transverse configuration of exciting a.c and biasing d.c fields.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا