Do you want to publish a course? Click here

Cold Atmospheric Plasma Sterilization of FFP3 Face Masks and Long-Term Material Effects

119   0   0.0 ( 0 )
 Added by Alisa Schmidt
 Publication date 2021
  fields Physics
and research's language is English




Ask ChatGPT about the research

The use of cold atmospheric plasmas (CAP) to sterilize sensitive surfaces is an interesting new field of applied plasma physics. Motivated by the shortages of face masks and safety clothing at the beginning of the corona pandemic, we conducted studies on the sterilization of FF3 face masks with CAP and the resulting material effects. Therefore, the bactericidal and sporicidal efficacy of CAP afterglow sterilization of FFP3 mask material was investigated by inoculating fabric samples with test germs Escherichia coli (E. coli) and Bacillus atrophaeus (B. atrophaeus) and subsequent CAP afterglow treatment in a surface-micro-discharge (SMD) plasma device. In addition, a detailed analysis of the changes in long-term plasma treated (15h) mask material and its individual components - ethylene vinyl acetate (EVA) and polypropylene (PP) - was carried out using surface analysis methods such as laser microscopy, contact angle measurements, X-ray photoelectron spectroscopy (XPS) as well as fabric permeability and resistance measurements. The experiments showed that E. coli and B. atrophaeus could both be effectively inactivated by plasma treatment in nitrogen mode (12 kVpp, 5 kHz). For B. atrophaeus inactivation of more than 4-log was achieved after 30 minutes. E. coli population could be reduced by 5-log within one minute of CAP treatment and after five minutes a complete inactivation (> 6-log) was achieved. Material analysis showed that long-term (> 5 h) plasma treatment affects the electrostatic properties of the fabric. From this it can be deduced that the plasma treatment of FFP3 face masks with the CAP afterglow of an SMD device effectively inactivates microorganisms on the fabric. FFP3 masks can be plasma decontaminated and reused multiple times but only to a limited extent, as otherwise the permeability levels no longer meet the DIN EN 149 specifications.



rate research

Read More

Inactivation of microorganisms on sensitive surfaces by cold atmospheric plasma (CAP) is one major application in the field of plasma medicine because it provides a simple and effective way to sterilize heat-sensitive materials. Therefore, one has to know whether plasma treatment affects the treated surfaces, and thus causes long-term surface modifications. In this contribution, the effect of cold atmospheric Surface Micro-Discharge (SMD) plasma on different materials and its sporicidal behavior was investigated. Hence, different material samples (stainless steel, different polymers and glass) were plasma-treated for 16 hours, simulating multiple plasma treatments using an SMD plasma device. Afterwards, the material samples were analyzed using surface analysis methods such as laser microscopy, contact angle measurements and X-ray photoelectron spectroscopy (XPS). Furthermore, the device was used to investigate the behavior of Bacillus atrophaeus endospores inoculated on material samples at different treatment times. The interaction results for plasma-treated endospores show, that a log reduction of the spore count between 4.3 and 6.2 can be achieved within 15 min of plasma treatment. Besides, the surface analysis revealed, that there were three different types of reactions the probed materials showed to plasma treatment, ranging from no changes to shifts of the materials free surface energies and oxidation. As a consequence, it should be taken into account that even though cold atmospheric plasma treatment is a non-thermal method to inactivate microorganisms on heatsensitive materials, it still affects surface properties of the treated materials. Therefore, the focus of future work must be a further classification of plasma-caused material modifications.
134 - Dayun Yan , Haitao Cui , Wei Zhu 2017
Hydrogen peroxide (H2O2) is an important signaling molecule in cancer cells. However, the significant secretion of H2O2 by cancer cells have been rarely observed. Cold atmospheric plasma (CAP) is a near room temperature ionized gas composed of neutral particles, charged particles, reactive species, and electrons. Here, we first demonstrated that breast cancer cells and pancreatic adenocarcinoma cells generated micromolar level H2O2 during just 1 min of direct CAP treatment on these cells. The cell-based H2O2 generation is affected by the medium volume, the cell confluence, as well as the discharge voltage. The application of cold atmospheric plasma (CAP) in the cancer treatment has been intensively investigated over the past decade. Several cellular responses to the CAP treatment have been observed including the consumption of the CAP-originated reactive species, the rise of intracellular reactive oxygen species, the damage on DNA and mitochondria, as well as the activation of apoptotic events. This is a new previously unknown cellular response to CAP, which provides a new prospective to understand the interaction between CAP and cells.
Cold atmospheric plasma (CAP) was shown to affect cells not only directly, but also indirectly by means of plasma pre-treated solution. This study investigated a new application of CAP generated in deionized (DI) water for the cancer therapy. In our experiments, the CAP solution was generated in DI water using helium as carrier gas. We report on the effects of this plasma solution in breast (MDA-MD-231) and gastric (NCI-N87) cancer cells. The results revealed that apoptosis efficiency was dependent on the plasma exposure time and on the levels of reactive oxygen and nitrogen species (ROS and RNS). The plasma solution that resulted from 30-minute treatment of DI water had the most significant effect in the rate of apoptosis.
306 - Mounir Laroussi 2021
This mini review is to introduce the readers of Plasma to the field of plasma medicine. This is a multidisciplinary field of research at the intersection of physics, engineering, biology and medicine. Plasma medicine is only about two decades old, but the research community active in this emerging field has grown tremendously in the last few years. Today, research is being conducted on a number of applications including wound healing and cancer treatment. Although a lot of knowledge has been created and our understanding of the fundamental mechanisms that play important roles in the interaction between low temperature plasma and biological cells and tissues has greatly expanded, much remains to be done to get a thorough and detailed picture of all the physical and biochemical processes that enter into play.
64 - F. Judee , J. Vaquero , S. Guegan 2019
Two atmospheric pressure plasma jet devices - a plasma gun and a plasma Tesla jet - are compared in terms of safety and therapeutic efficiency to reduce the tumor volume progression of cholangiocarcinoma, i.e. a rare and very aggressive cancer emerging in biliary tree. For this, a three steps methodology is carried out. First, the two APPJ have been benchmarked in regard to their electrical and physico-chemical properties while interacting with material targets: dielectric plate, liquid sample, metal plate and an equivalent electrical circuit of human body. The propagation properties of the ionization wave interacting with these targets are discussed, in particular the profile of the related pulsed atmospheric plasma streams. In a second step, a dermal toxicity survey is performed so as to define an experimental operating window where plasma parameters can be changed without damaging healthy skin of mice during their exposure to plasma and without inducing any electrical hazards (burnings, ventricular fibrillation). Optimal conditions are identified discarding the conditions where slight alterations may be evidenced by histology (e.g. prenecrotic aspect of keratinocytes, alterations in the collagen structure). Hence, for the two APPJ plasma parameters these conditions are as follow: duty cycle=14 %, repetition frequency=30 kHz, magnitude=7 kV, gap=10 mm and exposure time=1 min. In a third step, the two plasma jets are utilized on cholangiocarcinoma xenograft tumor model developed in immunodeficient mice. The two devices are safe and a significant therapeutic efficiency is demonstrated with the plasma Tesla. In conclusion, we have developed a safe cold atmospheric plasma device with antitumoral properties in preclinical model of cholangiocarcinoma, opening the path for new anticancer treatment opportunities.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا