In this paper, we present a data-driven secondary controller for regulating to some desired values several variables of interest in a power system, namely, electrical frequency, voltage magnitudes at critical buses, and active power flows through critical lines. The power generation system is based on distributed energy resources (DERs) interfaced with either grid-forming (GFM) or grid-following (GFL) inverters. The secondary controller is based on online feedback optimization leveraging the learned sensitivities of the changes in the system frequency, voltage magnitudes at critical buses, and active power flows through critical lines to the changes in inverter active and reactive power setpoints. To learn the sensitivities accurately from data, the feedback optimization has a built-in mechanism for keeping the secondary control inputs persistently exciting without degrading its performance. The feedback optimization also utilizes the learned power-voltage characteristics of photovoltaic (PV) arrays to compute DC-link voltage setpoints so as to allow the PV arrays to track the power setpoints. To learn the power-voltage characteristics, we separately execute a data-driven approach that fits a concave polynomial to the collected power-voltage measurements by solving a sum-of-squares (SoS) optimization. We showcase the secondary controller using the modified IEEE-14 bus test system, in which conventional energy sources are replaced with inverter-interfaced DERs.
The present distribution grids generally have limited sensing capabilities and are therefore characterized by low observability. Improved observability is a prerequisite for increasing the hosting capacity of distributed energy resources such as solar photovoltaics (PV) in distribution grids. In this context, this paper presents learning-aided low-voltage estimation using untapped but readily available and widely distributed sensors from cable television (CATV) networks. The CATV sensors offer timely local voltage magnitude sensing with 5-minute resolution and can provide an order of magnitude more data on the state of a distribution system than currently deployed utility sensors. The proposed solution incorporates voltage readings from neighboring CATV sensors, taking into account spatio-temporal aspects of the observations, and estimates single-phase voltage magnitudes at all non-monitored buses using random forest. The effectiveness of the proposed approach was demonstrated using a 1572-bus feeder from the SMART-DS data set for two case studies - passive distribution feeder (without PV) and active distribution feeder (with PV). The analysis was conducted on simulated data, and the results show voltage estimates with a high degree of accuracy, even at extremely low percentages of observable nodes.
Energy savings from efficiency methods in individual residential buildings are measured in 10s of dollars, while the energy savings from such measures nationally would amount to 10s of billions of dollars, leading to the tragedy of the commons effect. The way out of this situation is via deployment of automated, integrated residential energy systems, that provide the user with a seamless, cost effective service leading to improvement of comfort and residential experience. Models are of critical importance in this context, as intelligent operating systems depend on them strongly. However, most of the currently used models of thermal behavior of buildings have high complexity leading to problems and implementation. The complexity also obscures the utilization of well know physical properties of buildings such as the thermal mass. In view of this, we investigate data-driven, simple-to-implement residential environmental models that can serve as the basis for energy saving algorithms in both retrofits and new designs of residential buildings. Despite the nonlinearity of the underlying dynamics, using Koopman operator theory framework in this study we show that a linear second order model embedding, that captures the physics that occur inside a single or multi-zone space does well when compared with data simulated using EnergyPlus. This class of models has low complexity. We show that their parameters have physical significance for the large-scale dynamics of a building and are correlated to concepts such as the thermal mass. We investigate consequences of changing the thermal mass on the energy behavior of a building system and provide best practice design suggestions.
The rapid deployment of distributed energy resources (DERs) in distribution networks has brought challenges to balance the system and stabilize frequency. DERs have the ability to provide frequency regulation; however, existing dynamic frequency simulation tools-which were developed mainly for the transmission system-lack the capability to simulate distribution network dynamics with high penetrations of DERs. Although electromagnetic transient (EMT) simulation tools can simulate distribution network dynamics, the computation efficiency limits their use for large-scale transmission-and-distribution (T&D) simulations. This paper presents an efficient T&D dynamic frequency co-simulation framework for DER frequency response based on the HELICS platform and existing off-the-shelf simulators. The challenge of synchronizing frequency between the transmission network and DERs hosted in the distribution network is approached by detailed modeling of DERs in frequency dynamic models while DER phasor models are also preserved in the distribution networks. Thereby, local voltage constraints can be respected when dispatching the DER power for frequency response. The DER frequency responses (primary and secondary)-are simulated in case studies to validate the proposed framework. Lastly, fault-induced delayed voltage recovery (FIDVR) event of a large system is presented to demonstrate the efficiency and effectiveness of the overall framework.
In this paper, we propose and experimentally validate a scheduling and control framework for distributed energy resources (DERs) that achieves to track a day-ahead dispatch plan of a distribution network hosting controllable and stochastic heterogeneous resources while respecting the local grid constraints on nodal voltages and lines ampacities. The framework consists of two algorithmic layers. In the first one (day-ahead scheduling), we determine an aggregated dispatch plan. In the second layer (real-time control), a distributed model predictive control (MPC) determines the active and reactive power set-points of the DERs so that their aggregated contribution tracks the dispatch plan while obeying to DERs operational constraints as well as the grids ones. The proposed framework is experimentally validated on a real-scale microgrid that reproduces the network specifications of the CIGRE microgrid benchmark system.
In this paper we study a discrete-time SIS (susceptible-infected-susceptible) model, where the infection and healing parameters and the underlying network may change over time. We provide conditions for the model to be well-defined and study its stability. For systems with homogeneous infection rates over symmetric graphs,we provide a sufficient condition for global exponential stability (GES) of the healthy state, that is, where the virus is eradicated. For systems with heterogeneous virus spread over directed graphs, provided that the variation is not too fast, a sufficient condition for GES of the healthy state is established.