We present the results of neutron detection in a laser plasma experiment with a CD$_2$ nanowire target. A hybrid semiconductor pixel detector Timepix3 covered with neutron converters was used for the detection of neutrons. D-D fusion neutrons were detected in a polyethylene converter through recoiled protons. Both the energy of recoiled protons and the time-of-flight of neutrons (and thus their energy) were determined. We report $(2.4 pm 1.8) times 10^7$ neutrons generated for 1~J of incoming laser energy. Furthermore, we proved that Timepix3 is suitable for difficult operational conditions in laser experiments.
Integral neutronics experiments have been investigated at Institute of Modern Physics, Chinese Academy of Sciences (IMP, CAS) in order to validate evaluated nuclear data related to the design of Chinese Initiative Accelerator Driven Systems (CIADS). In present paper, the accuracy of evaluated nuclear data for Tungsten has been examined by comparing measured leakage neutron spectra with calculated ones. Leakage neutron spectra from the irradiation of D-T neutrons on Tungsten slab sample were experimentally measured at 60$^{circ}$ and 120$^{circ}$ by using a time-of-flight method. Theoretical calculations are carried out by Monte Carlo neutron transport code MCNP-4C with evaluated nuclear data of the ADS-2.0, ENDF/B-VII.0, ENDF/B-VII.1, JENDL-4.0 and CENDL-3.1 libraries. From the comparisons, it is found that the calculations with ADS-2.0 and ENDF/B-VII.1 give good agreements with the experiments in the whole energy regions at 60$^{circ}$, while a large discrepancy is observed at 120$^{circ}$ in the elastic scattering peak, caused by a slight difference in the oscillation pattern of the elastic angular distribution at angles larger than 20$^{circ}$. However, the calculated spectra using data from ENDF/B-VII.0, JENDL-4.0 and CENDL-3.1 libraries showed larger discrepancies with the measured ones, especially around 8.5-13.5 MeV. Further studies are presented for these disagreements.
A construction of a thermal neutron testing detector with a thin [ZnS(Ag)+$^6$LiF] scintillator is described. Results of an investigation of sources of the detector pulse origin and the pulse features in a ground and underground conditions are presented. Measurements of the scintillator own background, registration efficiency and a neutron flux at different objects of the BNO INR RAS were performed. The results are compared with the ones measured by the $^3$He proportional counter.
The hybrid pixel detector Timepix3 allows the measurement of the time and energy deposition of an event simultaneously in each 55 $mu$m pixel, which makes Timepix3 a promising approach for a compact Compton camera. However, in Compton camera based on this kind of pixelated detector, the angular resolution is degraded in imaging of MeV gamma sources, because the diffusion of energetic Compton electron or photoelectron could trigger many pixels and lead to an inaccurate measurement of interaction position. In this study, an electron track algorithm is used to reconstruct the interaction point. From the demonstration of a Timepix3-based single layer Compton camera, a significant improvement of angular resolution is shown experimentally. The Timepix3-based single layer Compton camera could provide an ARM of 14 degrees (FWHM) in imaging of a Co-60 gamma source.
Recent results on the particle detector R&D for new accelerators are reviewed. Different approaches for the muon systems, hadronic and electromagnetic calorimeters, particle identification devices, and central trackers are discussed. Main emphasis is made on the detectors for the International Linear Collider and Super B-factory. A detailed description of a novel photodetector, a so called Silicon Photomultiplier, and its applications in scintillator detectors is presented.
Diamonds are very promising candidates for the neutron diagnostics in harsh environments such as fusion reactor. In the first place this is because of their radiation hardness, exceeding that of Silicon by an order of magnitude. Also, in comparison to the standard on-line neutron diagnostics (fission chambers, silicon based detectors, scintillators), diamonds are less sensitive to $gamma$ rays, which represent a huge background in fusion devices. Finally, their low leakage current at high temperature suppresses the detector intrinsic noise. In this talk a CVD diamond based detector has been proposed for the measurement of the 14 MeV neutrons from D-T fusion reaction. The detector was arranged in a proton recoil telescope configuration, featuring a plastic converter in front of the sensitive volume in order to induce the (n,p) reaction. The segmentation of the sensitive volume, achieved by using two crystals, allowed to perform measurements in coincidence, which suppressed the neutron elastic scattering background. A preliminary prototype was assembled and tested at FNG (Frascati Neutron Generator, ENEA), showing promising results regarding efficiency and energy resolution.