No Arabic abstract
Frequency combs have triggered an impressive evolution of optical metrology across diverse regions of the electromagnetic spectrum, from the ultraviolet to the terahertz frequencies. An unexplored territory, however, remains in the region of vibrational bending modes, mostly due to the lack of single-mode lasers in the long-wavelength (LW) part of the mid-infrared (MIR) spectrum. We fill this gap through a purely MIR-based nonlinear laser source with tunability from 12.1 to 14.8 $mu$m, optical power up to 110 $mu$W, MHz-level linewidth and comb calibration. This enables the first example of bending modes metrology in this region, with the assessment of several CO$_2$-based frequency benchmarks with uncertainties down to 30 kHz, and the accurate study of the $ u_{11}$ band of benzene, which is a significant testbed for the resolution of the spectrometer. These achievements pave the way for LW-MIR metrology, rotationally-resolved studies and astronomic observations of large molecules, such as aromatic hydrocarbons.
Low noise and high repetition rate optical frequency combs are desirable for many applications from timekeeping to precision spectroscopy. For example, gigahertz repetition rate sources greatly increase the acquisition speed of spectra in a dual-comb modality when compared to lower repetition rate sources, while still maintaining sufficient instantaneous resolution to resolve ro-vibrational signatures from molecules in a variety of conditions. In this paper, we present the stabilization and characterization of a turnkey commercial 1~GHz mode-locked laser that operates at telecom wavelengths (1.56 $mu$m). Fiber amplification and spectral broadening result in the high signal-to-noise ratio detection and stabilization of $textit{f}_{textit{ceo}}$ with 438 mrad of residual phase noise (integrated from 10$^2$ to 10$^7$ Hz). Simultaneously, we stabilize the beatnote between the nearest comb mode and a cavity stabilized continuous-wave laser at 1.55 $mu$m with 41 mrad of residual phase noise (integrated from 10$^2$ to 10$^7$ Hz). This robust, self-referenced comb system is built with off-the-shelf polarization-maintaining fiber components and will be useful for a wide range of low noise frequency comb applications that benefit from the increased repetition rate.
Highly sensitive terahertz (THz) sensors for a myriad of applications are rapidly evolving. A widespread sensor concept is based on the detection of minute resonance frequency shifts due to a targeted specimen in the sensors environment. Therefore, cutting-edge high resolution continuous wave (CW) THz spectrometers provide very powerful tools to investigate the sensors performances. However, unpredictable yet non negligible frequency drifts common to state-of-the-art CW THz spectrometers limit the sensors accuracy for ultra-high precision sensing and metrology. Here, we overcome this deficiency by introducing an ultra-high quality (Q) THz microresonator frequency reference. Measuring the sensors frequency shift relative to a well-defined frequency reference eliminates the unwanted frequency drift, and fully exploits the capabilities of modern CW THz spectrometers as well as THz sensors. In a proof-of-concept experiment, we demonstrate the accurate and repeated detection of minute resonance frequency shifts of less than 5MHz at 0.6THz of a THz microresonator sensor.
The MEG experiment took data at the Paul Scherrer Institute in the years 2009--2013 to test the violation of the lepton flavour conservation law, which originates from an accidental symmetry that the Standard Model of elementary particle physics has, and published the most stringent limit on the charged lepton flavour violating decay ${mu}^+ rightarrow {rm e}^+ gamma$: BR(${mu}^+ rightarrow {rm e}^+ gamma$) $<4.2 times 10^{-13}$ at 90% confidence level. The MEG detector has been upgraded in order to reach a sensitivity of $6times10^{-14}$. The basic principle of MEG II is to achieve the highest possible sensitivity using the full muon beam intensity at the Paul Scherrer Institute ($7times10^{7}$ muons/s) with an upgraded detector. The main improvements are better rate capability of all sub-detectors and improved resolutions while keeping the same detector concept. In this paper, we present the current status of the preparation, integration and commissioning of the MEG II detector in the recent engineering runs.
A charge-coupled device (CCD) is a standard imager in optical region in which the image quality is limited by its pixel size. CCDs also function in X-ray region but with substantial differences in performance. An optical photon generates only one electron while an X-ray photon generates many electrons at a time. We developed a method to precisely determine the X-ray point of interaction with subpixel resolution. In particular, we found that a back-illuminated CCD efficiently functions as a fine imager. We present here the validity of our method through an actual imaging experiment.
We report on higly accurate absolute frequency measurement against a femtosecond frequency comb of 6 saturated absorption lines of formic acid (HCOOH) with an accuracy of 1 kHz. We also report the frequency measurement of 17 other lines with an accuracy of 2 kHz. Those lines are in quasi coincidence with the 9R(36) to 9R(42) CO$_2$ laser emission lines and are probed either by a CO$_2$ or a widely tunable quantum cascade laser phase locked to a master CO$_2$ laser. The relative stability of two HCOOH stabilized lasers is characterized by a relative Allan deviation of 4.5 10$^{-12}$ $tau^{-1/2}$. They give suitable frequency references for H$_2^+$ Doppler free two-photon spectroscopy.