No Arabic abstract
A transimpedance amplifier has been designed for scanning tunneling microscopy (STM). The amplifier features low noise (limited by the Johnson noise of the 1 G{Omega} feedback resistor at low input current and low frequencies), sufficient bandwidth for most STM applications (50 kHz at 35 pF input capacitance), a large dynamic range (0.1 pA--50 nA without range switching), and a low input voltage offset. The amplifier is also suited for placing its first stage into the cryostat of a low-temperature STM, minimizing the input capacitance and reducing the Johnson noise of the feedback resistor. The amplifier may also find applications for specimen current imaging and electron-beam-induced current measurements in scanning electron microscopy and as a photodiode amplifier with a large dynamic range. This paper also discusses the sources of noise including the often neglected effect of non-balanced input impedance of operational amplifiers and describes how to accurately measure and adjust the frequency response of low-current transimpedance amplifiers.
We present the design and characterisation of a low-noise, resonant input transimpedance amplified photodetector. The device operates at a resonance frequency of $90 ,textrm{MHz}$ and exhibits an input referred current noise of $1.2,textrm{pA}/sqrt{textrm{Hz}}$---marginally above the the theoretical limit of $1.0,textrm{pA}/sqrt{textrm{Hz}}$ set by the room temperature Johnson noise of the detectors $16,textrm{k}Omega$ transimpedance. As a result, the photodetector allows for shot-noise limited operation for input powers exceeding $14,mutextrm{W}$ at $461,textrm{nm}$ corresponding to a noise equivalent power of $3.5,textrm{pW}/sqrt{textrm{Hz}}$. The key design feature which enables this performance is a low-noise, common-source JFET amplifier at the input which helps to reduce the input referred noise contribution of the following amplification stages.
The cable capacitance in cryogenic and high vacuum applications of quartz tuning forks imposes severe constraints on the bandwidth and noise performance of the measurement. We present a single stage low noise transimpedance amplifier with a bandwidth exceeding 1 MHz and provide an in-depth analysis of the dependence of the amplifier parameters on the cable capacitance.
A simple, reliable method for preparation of bulk Cr tips for Scanning Tunneling Microscopy (STM) is proposed and its potentialities in performing high-quality and high-resolution STM and Spin Polarized-STM (SP-STM) are investigated. Cr tips show atomic resolution on ordered surfaces. Contrary to what happens with conventional W tips, rest atoms of the Si(111)-7x7 reconstruction can be routinely observed, probably due to a different electronic structure of the tip apex. SP-STM measurements of the Cr(001) surface showing magnetic contrast are reported. Our results reveal that the peculiar properties of these tips can be suited in a number of STM experimental situations.
We present the design and performance of a cryogenic scanning tunneling microscope (STM) which operates inside a water-cooled Bitter magnet, which can attain a magnetic field of up to 38 T. Due to the high vibration environment generated by the magnet cooling water, a uniquely designed STM and vibration damping system are required. The STM scan head is designed to be as compact and rigid as possible, to minimize the effect of vibrational noise as well as fit the size constraints of the Bitter magnet. The STM uses a differential screw mechanism for coarse tip - sample approach, and operates in helium exchange gas at cryogenic temperatures. The reliability and performance of the STM are demonstrated through topographic imaging and scanning tunneling spectroscopy (STS) on highly oriented pyrolytic graphite (HOPG) at T = 4.2 K and in magnetic fields up to 34 T.
A low-temperature ultra-high vacuum scanning probe microscopy (SPM) system with molecular beam epitaxy capability and optical access was conceived, built, and tested in our lab. The design of the whole system is discussed here, with special emphasis on some critical parts. We made an SPM scanner head with a modified Pan-type design, enclosed by a double-layer cold room under a bath type cryostat. The scanner head is very rigid, compatible with optical access paths, and can accommodate both scanning tunneling microscope (STM) tips and atomic force sensors. Two piezo-actuated focus-lens stages are mounted on the two sides of the cold room to couple light in and out. To demonstrate the system performance, we performed STM and scanning tunneling spectroscopy studies. The herringbone reconstruction and atomic structure of Au(111) surface were clearly resolved. The dI/dV spectra of an Au(111) surface were obtained at 5 K. In addition, a periodic 2D tellurium (Te) structure was grown on Au(111) surface using MBE.