Photon statistics and dynamics of nanolasers subject to intensity feedback

192   0   0.0 ( 0 )
 Added by Tao Wang
 Publication date 2019
  fields Physics
and research's language is English




Ask ChatGPT about the research

Using a fully stochastic numerical scheme, we investigate the behaviour of a nanolaser in the low-coherence regime at the transition between spontaneous emission and lasing under the influence of intensity feedback. Studying the input-output curves as well as the second order correlations for different feedback fractions, we obtain an insight on the role played by the fraction of photons reinjected into the cavity. The interpretation of the observation is strengthened through the comparison with the temporal traces of the emitted photons and with the radiofrequency power spectra. The results give insight into the physics of nanolasers as well as validate the use of the second order autocorrelation as a sufficient tool for the interpretation of the dynamics. This confirmation offers a solid basis for the reliance on autocorrelations in experiments studying the effects of feedback in nanodevices.



rate research

Read More

378 - David Elvira , V. Verma 2011
We report on the higher-order photon correlations of a high-$beta$ nanolaser under pulsed excitation at room temperature. Using a multiplexed four-element superconducting single photon detector we measured g$^{(n)}(vec{0})$ with $n$=2,3,4. All orders of correlation display partially chaotic statistics, even at four times the threshold excitation power. We show that this departure from coherence and Poisson statistics is due to the quantum fluctuations associated with the small number of dipoles and photons involved in the lasing process.
We develop a general method for customizing the intensity statistics of speckle patterns on a target plane. By judiciously modulating the phase-front of a monochromatic laser beam, we experimentally generate speckle patterns with arbitrarily-tailored intensity probability-density functions. Relative to Rayleigh speckles, our customized speckles exhibit radically different topologies yet maintain the same spatial correlation length. The customized speckles are fully developed, ergodic, and stationary: with circular non-Gaussian statistics for the complex field. Propagating away from the target plane, the customized speckles revert back to Rayleigh speckles. This work provides a versatile framework for tailoring speckle patterns with varied applications in microscopy, imaging and optical manipulation.
The different dynamical behaviors of the Hermite-Gaussian (HG) modes of mode-locked nanolasers based on a harmonic photonic cavity are investigated in detail using a model based on a modified Gross-Pitaevskii Equation. Such nanolasers are shown to exhibit mode-locking with a repetition rate independent of the cavity length, which is a strong asset for compactness.The differences with respect to conventional lasers are shown to originate from the peculiar gain competition between HG modes, which is investigated in details. In the presence of a saturable absorber, the different regimes, i. e. Q-switching, Q-switched mode-locking, and continuous-wave (cw) mode locking, are isolated in a phase diagram and separately described. Mode-locking is found to be robust against phase-intensity coupling and to be achievable in a scheme with spatially separated gain and absorber.
Intensity interferometry is a well known method in astronomy. Recently, a related method called incoherent diffractive imaging (IDI) was proposed to apply intensity correlations of x-ray fluorescence radiation to determine the 3D arrangement of the emitting atoms in a sample. Here we discuss inherent sources of noise affecting IDI and derive a model to estimate the dependence of the signal to noise ratio (SNR) on the photon counts per pixel, the temporal coherence (or number of modes), and the shape of the imaged object. Simulations in two- and three-dimensions have been performed to validate the predictions of the model. We find that contrary to coherent imaging methods, higher intensities and higher detected counts do not always correspond to a larger SNR. Also, larger and more complex objects generally yield a poorer SNR despite the higher measured counts. The framework developed here should be a valuable guide to future experimental design.
Developments in quantum technologies lead to new applications that require radiation sources with specific photon statistics. A widely used Poissonian statistics are easily produced by lasers; however, some applications require super- or sub-Poissonian statistics. Statistical properties of a light source are characterized by the second-order coherence function g^(2)(0). This function distinguishes stimulated radiation of lasers with g^(2)(0)=1 from light of other sources. For example, g^(2)(0)=2 for black-body radiation, and g^(2)(0)=0 for single-photon emission. One of the applications requiring super-Poissonian statistics (g^(2)(0)>1) is ghost imaging with thermal light. Ghost imaging also requires light with a narrow linewidth and high intensity. Currently, rather expensive and inefficient light sources are used for this purpose. In the last year, a superluminescent diode based on amplified spontaneous emission (ASE) has been considered as a new light source for ghost imaging. Even though ASE has been widely studied, its photon statistics has not been settled - there are neither reliable theoretical estimates of the second-order coherence function nor unambiguous experimental data. Our computer simulation clearly establishes that coherence properties of light produced by ASE are similar to that of a thermal source with g^(2)(0)=2 independent of pump power. This result manifests the fundamental difference between ASE and laser radiation.