Do you want to publish a course? Click here

The NA62 GigaTracKer: a low mass high intensity beam 4D tracker with 65 ps time resolution on tracks

72   0   0.0 ( 0 )
 Publication date 2019
  fields Physics
and research's language is English




Ask ChatGPT about the research

The GigaTracKer (GTK) is the beam spectrometer of the CERN NA62 experiment. The detector features challenging design specifications, in particular a peak particle flux reaching up to 2.0 MHz/mm$^2$, a single hit time resolution smaller than 200 ps and, a material budget of 0.5% X$_0$ per tracking plane. To fulfill these specifications, novel technologies were especially employed in the domain of silicon hybrid time-stamping pixel technology and micro-channel cooling. This article describes the detector design and reports on the achieved performance.



rate research

Read More

A large RICH detector is used in NA62 to suppress the muon contamination in the charged pion sample by a factor of 100 in the momentum range between 15 and 35 GeV/c. Cherenkov light is collected by 1952 photomultipliers placed at the upstream end. In this paper the characterization of the photomultipliers and the dedicated Frontend and Data Acquisition electronics are described, the time resolution and the light detection efficiency measurement are presented.
76 - J. H. Han , H. S. Ahn , J. B. Bae 2020
When testing and calibrating particle detectors in a test beam, accurate tracking information independent of the detector being tested is extremely useful during the offline analysis of the data. A general-purpose Silicon Beam Tracker (SBT) was constructed with an active area of 32.0 x 32.0 mm2 to provide this capability for the beam calibration of the Cosmic Ray Energetics And Mass (CREAM) calorimeter. The tracker consists of two modules, each comprised of two orthogonal layers of 380 {mu}m thick silicon strip sensors. In one module each layer is a 64-channel AC-coupled single-sided silicon strip detector (SSD) with a 0.5 mm pitch. In the other, each layer is a 32-channel DC-coupled single-sided SSD with a 1.0 mm pitch. The signals from the 4 layers are read out using modified CREAM hodoscope front-end electronics with a USB 2.0 interface board to a Linux DAQ PC. In this paper, we present the construction of the SBT, along with its performance in radioactive source tests and in a CERN beam test in October 2006.
The international PEN collaboration aims to obtain the branching ratio for the pion electronic decay $pi^+ to e^+ u_e(gamma)$, aka $pi_{e2}$, to a relative precision of $5times 10^{-4}$ or better. The PEN apparatus comprises a number of detection systems, all contributing vital information to the PEN event reconstruction. This paper discusses the design, performance, and Monte Carlo simulation of the mini time projection chamber (mTPC) used for pion, muon, and positron beam particle tracking. We also review the use of the extracted trajectory coordinates in the analysis, in particular in constructing observables critical for discriminating background processes, and in maximizing the fiducial volume of the target in which decay event vertices can be accepted for branching ratio extraction without introducing bias.
Timing-pick up detectors with excellent timing resolutions are essential in many modern nuclear physics experiments. Aiming to develop a Time-Of-Flight system with precision down to about 10 ps, we have made a systematic study of the timing characteristic of TOF detectors, which consist of several combinations of plastic scintillators and photomultiplier tubes. With the conventional electronics, the best timing resolution of about 5.1 ps ({sigma}) has been achieved for detectors with an area size of 3x1 cm2. It is found that for data digitalization a combination of TAC and ADC can achieve a better time resolution than currently available TDC. Simultaneously measurements of both time and pulse height are very valuable for correction of time-walk effect.
A semiconductor tracker for muon scattering tomography is presented. The tracker contains silicon strip sensors with an $80,mu$m pitch, precision mechanics and integrated cooling. The electronic readout of the sensors is performed by a scalable, inexpensive, flexible, FPGA-based system, which is demonstrated to achieve an event rate of $30,$kHz. The tracker performance is compared with a Geant4 simulation. A scattering angle resolution compatible with $1.5,$mrad at the $4,$GeV average cosmic ray muon energy is demonstrated. Images of plastic, iron and lead samples are obtained using an Angle Statistics Reconstruction algorithm. The images demonstrate good contrast between low and high atomic number materials.
comments
Fetching comments Fetching comments
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا