Do you want to publish a course? Click here

A Software-based Low-Jitter Servo Clock for Inexpensive Phasor Measurement Units

280   0   0.0 ( 0 )
 Added by Davide Brunelli PhD
 Publication date 2019
and research's language is English




Ask ChatGPT about the research

This paper presents the design and the implementation of a servo-clock (SC) for low-cost Phasor Measurement Units (PMUs). The SC relies on a classic Proportional Integral (PI) controller, which has been properly tuned to minimize the synchronization error due to the local oscillator triggering the on-board timer. The SC has been implemented into a PMU prototype developed within the OpenPMU project using a BeagleBone Black (BBB) board. The distinctive feature of the proposed solution is its ability to track an input Pulse-Per-Second (PPS) reference with good long-term stability and with no need for specific on-board synchronization circuitry. Indeed, the SC implementation relies only on one co-processor for real-time application and requires just an input PPS signal that could be distributed from a single substation clock.



rate research

Read More

A significant portion of the literature on fault localization assumes (more or less explicitly) that there are sufficient reliable measurements to guarantee that the system is observable. While several heuristics exist to break the observability barrier, they mostly rely on recognizing spatio-temporal patterns, without giving insights on how the performance are tied with the system features and the sensor deployment. In this paper, we try to fill this gap and investigate the limitations and performance limits of fault localization using Phasor Measurement Units (PMUs), in the low measurements regime, i.e., when the system is unobservable with the measurements available. Our main contribution is to show how one can leverage the scarce measurements to localize different type of distribution line faults (three-phase, single-phase to ground, ...) at the level of sub-graph, rather than with the resolution of a line. We show that the resolution we obtain is strongly tied with the graph clustering notion in network science.
The recent introduction of synchrophasor technology into power distribution systems has given impetus to various monitoring, diagnostic, and control applications, such as system identification and event detection, which are crucial for restoring service, preventing outages, and managing equipment health. Drawing on the existing framework for inferring topology and admittances of a power network from voltage and current phasor measurements, this paper proposes an online algorithm for event detection and localization in unbalanced three-phase distribution systems. Using a convex relaxation and a matrix partitioning technique, the proposed algorithm is capable of identifying topology changes and attributing them to specific categories of events. The performance of this algorithm is evaluated on a standard test distribution feeder with synthesized loads, and it is shown that a tripped line can be detected and localized in an accurate and timely fashion, highlighting its potential for real-world applications.
The electric power system is a cyber-physical system with power flow in the physical system and information flow in the cyber. Simulation is crucial to understanding the dynamics and control of electric power systems yet the underlying communication system has historically been ignored in these studies. This paper aims at meeting the increasing needs to simulate the operations of a real power system including the physical system, the energy management system, the communication system, and the emerging wide-area measurement-based controls. This paper proposes a cyber-physical testbed design and implementation for verifying and demonstrating wide-area control methods based on streaming telemetry and phasor measurement unit data. The proposed decoupled architecture is composed of a differential algebraic equation based physical system simulator, a software-defined network, a scripting language environment for prototyping an EMS system and a control system, all of which are integrated over industry-standard communication protocols. The proposed testbed is implemented using open-source software packages managed by a Python dispatcher. Finally, demonstrations are presented to show two wide-area measurement-based controls - system separation control and hierarchical voltage control, in the implemented testbed.
Networked Automation Systems (NAS) have to meet stringent response time during operation. Verifying response time of automation is an important step during design phase before deployment. Timing discrepancies due to hardware, software and communication components of NAS affect the response time. This investigation uses model templates for verifying the response time in NAS. First, jitter bounds model the timing fluctuations of NAS components. These jitter bounds are the inputs to model templates that are formal models of timing fluctuations. The model templates are atomic action patterns composed of three composition operators- sequential, alternative, and parallel and embedded in time wrapper that specifies clock driven activation conditions. Model templates in conjunction with formal model of technical process offer an easier way to verify the response time. The investigation demonstrates the proposed verification method using an industrial steam boiler with typical NAS components in plant floor.
Wide area measurement system (WAMS) is one of the essential components in the future power system. To make WAMS construction plans, practical models of the power network observability, reliability, and underlying communication infrastructures need to be considered. To address this challenging problem, in this paper we propose a unified framework for WAMS planning to cover most realistic concerns in the construction process. The framework jointly optimizes the system construction cost, measurement reliability, and volume of synchrophasor data traffic resulting in a multi-objective optimization problem, which provides multiple Pareto optimal solutions to suit different requirements by the utilities. The framework is verified on two IEEE test systems. The simulation results demonstrate the trade-off relationships among the proposed objectives. Moreover, the proposed framework can develop optimal WAMS plans for full observability with minimal cost. This work develops a comprehensive framework for most practical WAMS construction designs.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا