Do you want to publish a course? Click here

Joint X-ray, EUV and UV Observations of a Small Microflare

158   0   0.0 ( 0 )
 Added by Iain Hannah
 Publication date 2018
  fields Physics
and research's language is English




Ask ChatGPT about the research

We present the first joint observation of a small microflare in X-rays with the Nuclear Spectroscopic Telescope ARray (NuSTAR), UV with the Interface Region Imaging Spectrograph (IRIS) and EUV with the Solar Dynamics Observatory/Atmospheric Imaging Assembly (SDO/AIA). These combined observations allows us to study the microflares hot coronal and cooler chromospheric/transition region emission. This small microflare peaks from SOL2016-07-26T23:35 to 23:36UT, in both NuSTAR, SDO/AIA and IRIS. Spatially this corresponds to a small loop visible in the SDO/AIA Fe XVIII emission, which matches a similar structure lower in the solar atmosphere seen by IRIS in SJI1330{AA} and 1400AA. The NuSTAR emission in both 2.5-4 keV and 4-6 keV, is located in a small source at this loop location. The IRIS slit was over the microflaring loop, and fits show little change in Mg II but do show intensity increases, slight width enhancements and redshifts in Si IV andO IV, indicating that this microflare had most significance in and above the upper chromosphere. The NuSTAR microflare spectrum is well fitted by a thermal component of 5.8MK and $2.3times10^{44}$ cm$^{-3}$, which corresponds to a thermal energy of $10^{26}$ erg, making it considerably smaller than previously studied X-ray microflares. No non-thermal emission was detected but this could be due to the limited effective exposure time of the observation. This observation shows that even ordinary features seen in UV and EUV, can remarkably have a higher energy component that is clear in X-rays.



rate research

Read More

Solar flares are sudden energy release events in the solar corona, resulting from magnetic reconnection, that accelerates particles and heats the ambient plasma. During a flare, there are often multiple, temporally and spatially separated individual energy release episodes that can be difficult to resolve depending on the observing instrument. We present multi-wavelength imaging and spectroscopy observations of multiple electron acceleration episodes during a GOES B1.7-class two-ribbon flare on 2012 February 25, observed simultaneously with the Karl G. Jansky Very Large Array (VLA) at 1--2 GHz, the Reuven Ramatay High Energy Solar Spectroscopic Imager (RHESSI) in X-rays, and the Solar Dynamics Observatory in extreme ultraviolet (EUV). During the initial phase of the flare, five radio bursts were observed. A nonthermal X-ray source was seen co-temporal, but not co-spatial, with the first three radio bursts. Their radio spectra are interpreted as optically thick gyrosynchrotron emission. By fitting the radio spectra with a gyrosynchrotron model, we derive the magnetic field strength and nonthermal electron spectral parameters in each acceleration episode. Notably, the nonthermal parameters derived from X-rays differ considerably from the nonthermal parameters inferred from the radio. The observations are indicative of multiple, co-temporal acceleration episodes during the impulsive phase of a solar microflare. The X-ray and radio burst sources likely originate from separate electron distributions in different magnetic loops.
The Spectrometer/Telescope for Imaging X-rays (STIX) is the HXR instrument onboard Solar Orbiter designed to observe solar flares over a broad range of flare sizes, between 4-150 keV. We report the first STIX observations of microflares recorded during the instrument commissioning phase in order to investigate the STIX performance at its detection limit. This first result paper focuses on the temporal and spectral evolution of STIX microflares occuring in the AR12765 in June 2020, and compares the STIX measurements with GOES/XRS, SDO/AIA, and Hinode/XRT. For the observed microflares of the GOES A and B class, the STIX peak time at lowest energies is located in the impulsive phase of the flares, well before the GOES peak time. Such a behavior can either be explained by the higher sensitivity of STIX to higher temperatures compared to GOES, or due to the existence of a nonthermal component reaching down to low energies. The interpretation is inconclusive due to limited counting statistics for all but the largest flare in our sample. For this largest flare, the low-energy peak time is clearly due to thermal emission, and the nonthermal component seen at higher energies occurs even earlier. This suggests that the classic thermal explanation might also be favored for the majority of the smaller flares. In combination with EUV and SXR observations, STIX corroborates earlier findings that an isothermal assumption is of limited validity. Future diagnostic efforts should focus on multi-wavelength studies to derive differential emission measure distributions over a wide range of temperatures to accurately describe the energetics of solar flares. Commissioning observations confirm that STIX is working as designed. As a rule of thumb, STIX detects flares as small as the GOES A class. For flares above the GOES B class, detailed spectral and imaging analyses can be performed.
We present an analysis of soft X-ray (SXR) and extreme-ultraviolet (EUV) observations of solar flares with an approximate C8 GOES class. Our constraint on peak GOES SXR flux allows for the investigation of correlations between various flare parameters. We show that the the duration of the decay phase of a flare is proportional to the duration of its rise phase. Additionally, we show significant correlations between the radiation emitted in the flare rise and decay phases. These results suggest that the total radiated energy of a given flare is proportional to the energy radiated during the rise phase alone. This partitioning of radiated energy between the rise and decay phases is observed in both SXR and EUV wavelengths. Though observations from the EVE show significant variation in the behavior of individual EUV spectral lines during different C8 events, this work suggests that broadband EUV emission is well constrained. Furthermore, GOES and AIA data, allow us to determine several thermal parameters (e.g. temperature, volume, density, and emission measure) for the flares within our sample. Analysis of these parameters demonstrate that, within this constrained GOES class, the longer duration solar flares are cooler events with larger volumes capable of emitting vast amounts of radiation. The shortest C8 flares are typically the hottest events, smaller in physical size, and have lower associated total energies. These relationships are directly comparable with several scaling laws and flare loop models.
During transient events such as major solar eruptions, the plasma can be far from the equilibrium ionization state because of rapid heating or cooling. Non-equilibrium ionization~(NEI) is important in rapidly evolving systems where the thermodynamical timescale is shorter than the ionization or recombination time scales. We investigate the effects of NEI on EUV and X-ray observations by the Atmospheric Imaging Assembly (AIA) on board Solar Dynamic Observatory and X-ray Telescope (XRT) on board Hinode. Our model assumes that the plasma is initially in ionization equilibrium at low temperature, and it is heated rapidly by a shock or magnetic reconnection. We tabulate the responses of the AIA and XRT passbands as functions of temperature and a characteristic timescale, $n_{e}t$. We find that most of the ions reach equilibrium at $n_{e}tleq$10$^{12}$ cm$^{-3}$s. Comparing ratios of the responses between different passbands allows us to determine whether a combination of plasmas at temperatures in ionization equilibrium can account for a given AIA and XRT observation. It also expresses how far the observed plasma is from equilibrium ionization. We apply the ratios to a supra-arcade plasma sheet on 2012 January 27. We find that the closer the plasma is to the arcade, the closer it is to a single-temperature plasma in ionization equilibrium. We also utilize the set of responses to estimate the temperature and density for shocked plasma associated with a coronal mass ejection on 2010 June 13. The temperature and density ranges we obtain are in reasonable agreement with previous works.
Aims: The VY Scl system (anti-dwarf nova) V751 Cyg is examined following a claim of a super-soft spectrum in the optical low state. Methods: A serendipitous XMM-Newton X-ray observation and, 21 months later, Swift X-ray and UV observations, have provided the best such data on this source so far. These optical high-state datasets are used to study the flux and spectral variability of V751 Cyg. Results: Both the XMM-Newton and Swift data show evidence for modulation of the X-rays for the first time at the known 3.467 hr orbital period of V751 Cyg. In two Swift observations, taken ten days apart, the mean X-ray flux remained unchanged, while the UV source brightened by half a magnitude. The X-ray spectrum was not super-soft during the optical high state, but rather due to multi-temperature optically thin emission, with significant (10^{21-22} cm^-2) absorption, which was higher in the observation by Swift than that of XMM-Newton. The X-ray flux is harder at orbital minimum, suggesting that the modulation is related to absorption, perhaps linked to the azimuthally asymmetric wind absorption seen previously in H-alpha.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا