Do you want to publish a course? Click here

Very high brightness and power LCLS-II hard X-ray pulses

333   0   0.0 ( 0 )
 Added by Aliaksei Halavanau
 Publication date 2018
  fields Physics
and research's language is English




Ask ChatGPT about the research

We show the feasibility of generating X-ray pulses in the 4 to 8 keV fundamental photon energy range with 0.65 TW peak power, 15 fs pulse duration, $9times10^{-5}$ bandwidth, using the LCLS-II copper linac and hard X-ray (HXR) undulator. Third harmonic pulses with 8-12 GW peak power and narrow bandwidth are also generated. High power and small bandwidth X-rays are obtained using two electron bunches separated by about 1 ns, one to generate a high power seed signal, the other to amplify it by tapering the magnetic field of the HXR undulator. The bunch delay is compensated by delaying the seed pulse with a four crystals monochromator. The high power seed leads to higher output power and better spectral properties, with $>$94% of the X-ray power being within the near transform limited bandwidth. We discuss some of the experiments made possible by X-ray pulses with these characteristics, like single particle imaging and high field physics.



rate research

Read More

We propose a new scheme to generate high-brightness and temporal coherent soft x-ray radiation in a seeded free-electron laser. The proposed scheme is based the coherent harmonic generation (CHG) and superradiant principles. A CHG scheme is first used to generate coherent signal at ultra-high harmonics of the seed. This coherent signal is then amplified by a series of chicane-undulator modules via the fresh bunch and superradiant processes in the following radiator. Using a representative of realistic set of parameters, three-dimensional simulations have been carried out and the simulations results demonstrated that 10 GW-level ultra-short coherent radiation pulses in the water window can be achieved by using the proposed technique.
Transverse deflecting structures (TDS) are widely used in accelerator physics to measure the longitudinal density of particle bunches. When used in combination with a dispersive section, the whole longitudinal phase space density can be imaged. At the Linac Coherent Light Source (LCLS), the installation of such a device downstream of the undulators enables the reconstruction of the X-ray temporal intensity profile by comparing longitudinal phase space distributions with lasing on and lasing off. However, the resolution of this TDS is limited to around 1 fs rms (root mean square), and therefore, it is not possible to resolve single self-amplified spontaneous emission (SASE) spikes within one X-ray photon pulse. By combining the power spectrum from a high resolution photon spectrometer and the temporal structure from the TDS, the overall resolution is enhanced, thus allowing the observation of temporal, single SASE spikes. The combined data from the spectrometer and the TDS is analyzed using an iterative algorithm to obtain the actual intensity profile. In this paper, we present some improvements to the reconstruction algorithm as well as real data taken at LCLS.
101 - G. Wu , A. Grassellino , E. Harms 2018
Quality factor is a primary cost driver for high energy, continuous wave (CW) SRF linacs like the LCLS-II X-ray free electron laser currently under construction. Taking this into account, several innovations were introduced in the LCLS-II cryomodule design to push substantially beyond the previous state-of-the-art quality factor achieved in operation. This includes the first ever implementation of the nitrogen doping cavity treatment, the capability to provide high mass flow cooldown to improve expulsion of magnetic flux based on recent R&D, high performance magnetic shielding, and other critical subcomponents. To evaluate the implementation of these new cryomodule features, two prototype cryomodules were produced. In this paper, we present results from the prototype cryomodule assembled at Fermilab, which achieved unprecedented cavity quality factors of 3.0e10 at a nominal cryomodule voltage. We overview cavity performance, procedures to achieve ambient magnetic field < 5 mG at the cavity wall, and the successful demonstration of high mass flow cooldown in a cryomodule. The cavity performance under various cool down conditions are presented as well to show the impact of flux expulsion on Q0.
This paper describes the concept for the DArk Sector Experiments at LCLS-II (DASEL) facility which provides a near-CW beam of multi-GeV electrons to the SLAC End Station A for experiments in particle physics. The low-current multi-GeV electron beam is produced parasitically by the superconducting RF linac for the LCLS-II X-ray Free Electron Laser, which is under construction at SLAC. DASEL is designed to host experiments to detect light dark matter such as the Light Dark Matter eXperiment (LDMX) but can be configured to support a wide range of other experiments requiring current ranging from pico-amps to micro-amps.
Recent investigations of RF copper structures operated at cryogenic temperatures performed by a SLAC-UCLA collaboration have shown a dramatic increase in the maximum surface electric field, to 500 MV/m. We examine use of these fields to enable very high field cryogenic photoinjectors that can attain over an order of magnitude increase in peak electron beam brightness. We present beam dynamics studies relevant to X-ray FEL injectors, using start-to-end simulations that show the high brightness and low emittance of this source enables operation of a compact FEL reaching a photon energy of 80 keV. The preservation of beam brightness in compression, exploiting micro-bunching techniques is discussed. While the gain in brightness at high field is due to increase of the emission current density, further increases in brightness due to lowering of the intrinsic cathode emittance in cryogenic operation are also enabled. While the original proposal for this type of cryogenic, ultra-high field photoinjector has emphasized S-band designs, there are numerous potential advantages that may be conferred by operation in C-band. We examine issues related to experimental implementation in C-band, and expected performance of this type of device in a future hard X-ray FEL such as MaRIE.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا