Do you want to publish a course? Click here

Sub-picosecond photon-efficient 3D imaging using single-photon sensors

76   0   0.0 ( 0 )
 Added by Felix Heide
 Publication date 2018
  fields Physics
and research's language is English




Ask ChatGPT about the research

Active 3D imaging systems have broad applications across disciplines, including biological imaging, remote sensing and robotics. Applications in these domains require fast acquisition times, high timing resolution, and high detection sensitivity. Single-photon avalanche diodes (SPADs) have emerged as one of the most promising detector technologies to achieve all of these requirements. However, these detectors are plagued by measurement distortions known as pileup, which fundamentally limit their precision. In this work, we develop a probabilistic image formation model that accurately models pileup. We devise inverse methods to efficiently and robustly estimate scene depth and reflectance from recorded photon counts using the proposed model along with statistical priors. With this algorithm, we not only demonstrate improvements to timing accuracy by more than an order of magnitude compared to the state-of-the-art, but this approach is also the first to facilitate sub-picosecond-accurate, photon-efficient 3D imaging in practical scenarios where widely-varying photon counts are observed.

rate research

Read More

We propose a technique capable of imaging a distinct physical object with sub-Rayleigh resolution in an ordinary far-field imaging setup using single-photon sources and linear optical tools only. We exemplify our method for the case of a rectangular aperture and two or four single-photon emitters obtaining a resolution enhanced by a factor of two or four, respectively.
The routine atomic-resolution structure determination of single particles is expected to have profound implications for probing the structure-function relationship in systems ranging from energy materials to biological molecules. Extremely-bright, ultrashort-pulse X-ray sources---X-ray Free Electron Lasers (XFELs)---provide X-rays that can be used to probe ensembles of nearly identical nano-scale particles. When combined with coherent diffractive imaging, these objects can be imaged; however, as the resolution of the images approaches the atomic scale, the measured data are increasingly difficult to obtain and, during an X-ray pulse, the number of photons incident on the two-dimensional detector is much smaller than the number of pixels. This latter concern, the signal sparsity, materially impedes the application of the method. We demonstrate an experimental analog using a synchrotron X-ray source that yields signal levels comparable to those expected from single biomolecules illuminated by focused XFEL pulses. The analog experiment provides an invaluable cross-check on the fidelity of the reconstructed data that is not available during XFEL experiments. We establish---using this experimental data---that a sparsity of order $1.3times10^{-3}$ photons per pixel per frame can be overcome, lending vital insight to the solution of the atomic-resolution XFEL single particle imaging problem by experimentally demonstrating 3D coherent diffractive imaging from photon-sparse random projections.
We report 100% duty cycle generation of sub-MHz single photon pairs at the Rubidium D$_1$ line using cavity-enhanced spontaneous parametric downconversion. The temporal intensity crosscorrelation function exhibits a bandwidth of $666 pm 16$ kHz for the single photons, an order of magnitude below the natural linewidth of the target transition. A half-wave plate inside our cavity helps to achieve triple resonance between pump, signal and idler photon, reducing the bandwidth and simplifying the locking scheme. Additionally, stabilisation of the cavity to the pump frequency enables the 100% duty cycle. These photons are well-suited for storage in quantum memory schemes with sub-natural linewidths, such as gradient echo memories.
We present a monolithic semiconductor microcavity design for enhanced light-matter interaction and photon extraction efficiency of an embedded quantum emitter such as a quantum dot or color center. The microcavity is a hemispherical Fabry-Perot design consisting of a planar back mirror and a top curved mirror. Higher order modes are suppressed in the structure by reducing the height of the curved mirror, leading to efficient photon extraction into a fundamental mode with a Gaussian far-field radiation pattern. The cavity finesse can be varied easily by changing the reflectivity of the mirrors and we consider two specific cases: a low-finesse structure for enhanced broad band photon extraction from self-assembled quantum dots and a moderate-finesse cavity for enhanced extraction of single photons from the zero-phonon line of color centers in diamond. We also consider the impact of structural imperfections on the cavity performance. Finally, we present the fabrication and optical characterisation of monolithic GaAs hemispherical microcavities.
We investigate the detection of an ultra-bright single-photon source using highly efficient superconducting nanowire single-photon detectors (SNSPDs) at telecom wavelengths. Both the single-photon source and the detectors are characterized in detail. At a pump power of 100 mW (400 mW), the measured coincidence counts can achieve 400 kcps (1.17 Mcps), which is the highest ever reported at telecom wavelengths to the best of our knowledge. The multi-pair contributions at different pump powers are analyzed in detail. We compare the experimental and theoretical second order coherence functions $g^{(2)}(0)$ and find that the conventional experimentally measured $g^{(2)}(0)$ values are smaller than the theoretically expected ones. We also consider the saturation property of SNSPD and find that SNSPD can be easier to saturate with a thermal state rather than with a coherent state. The experimental data and theoretical analysis should be useful for the future experiments to detect ultra-bright down-conversion sources with high-efficiency detectors.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا