Do you want to publish a course? Click here

Longitudinal compression and transverse matching of electron bunch for external injection LPWA at ESCULAP

82   0   0.0 ( 0 )
 Added by Ke Wang
 Publication date 2017
  fields Physics
and research's language is English
 Authors K.Wang




Ask ChatGPT about the research

We present theoretical and numerical studies of longitudinal compression and transverse matching of electron bunch before injecting into the Laser-plasma Wake Field Accelerator (LWFA) foreseen at the ESCULAP project in ORSAY. Longitudinal compression is performed with a dogleg chicane, the chicane is designed based on theory of beam optics, beam dynamics in dogleg is studied with ImpactT and cross checked with CSRtrack, both 3D space charge (SC) and coherent synchrotron radiation (CSR) effects are included. Simulation results show that the energy chirp at the dogleg entrance should be smaller than the nominal optic design value, in order to compensate the negative energy chirp increase caused by longitudinal SC, while CSR can be ignored in our case. With an optimized configuration, the electron bunch ($sim$10MeV, 10pC) is compressed from 0.9ps RMS to 70fs RMS (53fs FWHM), with a peak current of 152A. Transverse matching is realized with a doublet and a triplet, they are matched with Madx and the electron bunch is tracked with ImpactT, simulation results show little difference with the nominal design values, that is due to the SC effect. Finally, by simply adjusting the quadrupole strength, a preliminary optimized configuration has been achieved, that matches the Courant-Snyder (C-S) parameters to $alpha_{x}=0.01$,$alpha_{y}=-0.02$, $beta_{x}=0.014$m,$beta_{y}=0.012$m at the plasma entrance.



rate research

Read More

256 - Benjamin Kehrer 2017
To understand and control the dynamics in the longitudinal phase space, time-resolved measurements of different bunch parameters are required. For a reconstruction of this phase space, the detector systems have to be synchronized. This reconstruction can be used e.g. for studies of the micro-bunching instability. It occurs if the interaction of the bunch with its own radiation leads to the formation of sub-structures on the longitudinal bunch profile. These sub-structures can grow rapidly -- leading to a sawtooth-like behaviour of the bunch. At KARA, we use a fast-gated intensified camera for energy spread studies, Schottky diodes for coherent synchrotron radiation studies as well as electro-optical spectral decoding for longitudinal bunch profile measurements. For a synchronization, a hardware synchronization scheme is used which compensates for eventual hardware delays. In this paper, the different experimental setups and their synchronization are discussed and first results of synchronous measurements are presented.
We demonstrate the electromagnetic performance of waveguides for femtosecond electron beam bunch manipulation and compression with strong-field terahertz (THz) pulses. The compressor structure is a dispersion-free exponentially-tapered parallel-plate waveguide (PPWG) that can focus single-cycle THz pulses along one dimension. We show test results of the tapered PPWG structure using electro-optic sampling (EOS) at the interaction region with peak fields of at least 300 kV/cm given 0.9 uJ of incoming THz energy. We also present a modified shorted design of the tapered PPWG for better beam manipulation and reduced magnetic field as an alternative to a dual-feed approach. As an example, we demonstrate that with 5 uJ of THz energy, the PPWG compresses a 2.5 MeV electron bunch by a compression factor of more than 4 achieving a bunch length of about 18 fs.
Realization of a short bunch beam by manipulating the longitudinal phase space distribution with a finite longitudinal dispersion following an off-crest accelera- tion is a widely used technique. The technique was applied in a compact test accelerator of an energy-recovery linac scheme for compressing the bunch length at the return loop. A diagnostic system utilizing coherent transition radiation was developed for the beam tuning and for estimating the bunch length. By scanning the beam parameters, we experimentally found the best condition for the bunch compression. The RMS bunch length of 250+-50 fs was obtained at a bunch charge of 2 pC. This result confirmed the design and the tuning pro- cedure of the bunch compression operation for the future energy-recovery linac (ERL).
We present the first demonstration of THz-driven bunch compression and timing stabilization of a few-fC relativistic electron beam with kinetic energy of 2.5 MeV using quasi-single-cycle strong field THz radiation in a shorted parallel-plate structure. Compression by nearly a factor of 3 produced a 39 fs rms bunch length and a reduction in timing jitter by more than a factor of 2, to 31 fs rms, offering a significant improvement to beam performance for applications like ultrafast electron diffraction. This THz-driven technique provides a critical step towards unprecedented timing resolution in ultrafast sciences and other accelerator applications using femtosecond-scale electron beams.
We use beam position measurements over the first part of the AWAKE electron beamline, together with beamline modeling, to deduce the beam average momentum and to predict the beam position in the second part of the beamline. Results show that using only the first five beam position monitors leads to much larger differences between predicted and measured positions at the last two monitors than when using the first eight beam position monitors. These last two positions can in principle be used with ballistic calculations to predict the parameters of closest approach of the electron bunch with the proton beam. In external injection experiments of the electron bunch into plasma wakefields driven by the proton bunch, only the first five beam position monitors measurements remain un-affected by the presence of the much higher charge proton bunch. Results with eight beam position monitors show the prediction method works in principle to determine electron and proton beams closest approach within the wakefields width ($<$1,mm), corresponding to injection of electrons into the wakefields. Using five beam position monitors is not sufficient.
comments
Fetching comments Fetching comments