Do you want to publish a course? Click here

Cadmium Zinc Telluride Imager onboard AstroSat : a multi-faceted hard X-ray instrument

231   0   0.0 ( 0 )
 Added by Arikkala Rao
 Publication date 2017
  fields Physics
and research's language is English




Ask ChatGPT about the research

The AstroSat satellite is designed to make multi-waveband observations of astronomical sources and the Cadmium Zinc Telluride Imager (CZTI) instrument of AstroSat covers the hard X-ray band. CZTI has a large area position sensitive hard X-ray detector equipped with a Coded Aperture Mask, thus enabling simultaneous background measurement. Ability to record simultaneous detection of ionizing interactions in multiple detector elements is a special feature of the instrument and this is exploited to provide polarization information in the 100 - 380 keV region. CZTI provides sensitive spectroscopic measurements in the 20 - 100 keV region, and acts as an all sky hard X-ray monitor and polarimeter above 100 keV. During the first year of operation, CZTI has recorded several gamma-ray bursts, measured the phase resolved hard X-ray polarization of the Crab pulsar, and the hard X-ray spectra of many bright Galactic X-ray binaries. The excellent timing capability of the instrument has been demonstrated with simultaneous observation of the Crab pulsar with radio telescopes like GMRT and Ooty radio telescope.



rate research

Read More

AstroSat is Indias first space-based astronomical observatory, launched on September 28, 2015. One of the payloads aboard AstroSat is the Cadmium Zinc Telluride Imager (CZTI), operating at hard X-rays. CZTI employs a two-dimensional coded aperture mask for the purpose of imaging. In this paper, we discuss various image reconstruction algorithms adopted for the test and calibration of the imaging capability of CZTI and present results from CZTI on-ground as well as in-orbit image calibration.
We are currently developing Cadmium Zinc Telluride (CZT) detectors for a next-generation space-borne hard X-ray telescope which can follow up on the highly successful NuSTAR (Nuclear Spectroscopic Telescope Array) mission. Since the launch of NuSTAR in 2012, there have been major advances in the area of X-ray mirrors, and state-of-the-art X-ray mirrors can improve on NuSTARs angular resolution of ~1 arcmin Half Power Diameter (HPD) to 15 or even 5 HPD. Consequently, the size of the detector pixels must be reduced to match this resolution. This paper presents detailed simulations of relatively thin (1 mm thick) CZT detectors with hexagonal pixels at a next-neighbor distance of 150 $mu$m. The simulations account for the non-negligible spatial extent of the deposition of the energy of the incident photon, and include detailed modeling of the spreading of the free charge carriers as they move toward the detector electrodes. We discuss methods to reconstruct the energies of the incident photons, and the locations where the photons hit the detector. We show that the charge recorded in the brightest pixel and six adjacent pixels suffices to obtain excellent energy and spatial resolutions. The simulation results are being used to guide the design of a hybrid application-specific integrated circuit (ASIC)-CZT detector package.
The High Resolution Energetic X-Ray Imager (HREXI) CZT detector development program at Harvard is aimed at developing tiled arrays of finely pixelated CZT detectors for use in wide-field coded aperture 3-200 keV X-ray telescopes. A pixel size of $simeq$ 600 $mu m$ has already been achieved in the ProtoEXIST2 (P2) detector plane with CZT read out by the NuSTAR ASIC. This paves the way for even smaller 300 $mu m$ pixels in the next generation HREXI detectors. This article describes a new HREXI calibration facility (HCF) which enables a high resolution sub-pixel level (100 $mu m$) 2D scan of a 256 $cm^2$ tiled array of 2 $times$ 2 cm CZT detectors illuminated by a bright X-ray AmpTek Mini-X tube source at timescales of around a day. HCF is a significant improvement from the previous apparatus used for scanning these detectors which took $simeq$ 3 weeks to complete a 1D scan of a similar detector plane. Moreover, HCF has the capability to scan a large tiled array of CZT detectors ($32cm times 32cm$) at 100 $mu m$ resolution in the 10 - 50 keV energy range which was not possible previously. This paper describes the design, construction, and implementation of HCF for the calibration of the P2 detector plane.
The Hard X-ray Imager (HXI) onboard Hitomi (ASTRO-H) is an imaging spectrometer covering hard X-ray energies of 5-80 keV. Combined with the hard X-ray telescope, it enables imaging spectroscopy with an angular resolution of $1^prime.7$ half-power diameter, in a field of view of $9^primetimes9^prime$. The main imager is composed of 4 layers of Si detectors and 1 layer of CdTe detector, stacked to cover wide energy band up to 80 keV, surrounded by an active shield made of BGO scintillator to reduce the background. The HXI started observations 12 days before the Hitomi loss, and successfully obtained data from G21.5$-$0.9, Crab and blank sky. Utilizing these data, we calibrate the detector response and study properties of in-orbit background. The observed Crab spectra agree well with a powerlaw model convolved with the detector response, within 5% accuracy. We find that albedo electrons in specified orbit strongly affect the background of Si top layer, and establish a screening method to reduce it. The background level over the full field of view after all the processing and screening is as low as the pre-flight requirement of $1$-$3times10^{-4}$ counts s$^{-1}$ cm$^{-2}$ keV$^{-1}$.
Understanding and reducing the in-orbit instrumental backgrounds are essential to achieving high sensitivity in hard X-ray astronomical observations. The observational data of the Hard X-ray Imager (HXI) on board the Hitomi satellite provides useful information on the background components, owing to its multi-layer configuration with different atomic numbers: the HXI consists of a stack of four layers of Si (Z = 14) detectors and one layer of CdTe (Z = 48, 52) detector surrounded by well-type BGO (Bi4Ge3O12) active shields. Based on the observational data, the backgrounds of top Si layer, the three underlying Si layers, and the CdTe layer are inferred to be dominated by different components, namely, low-energy electrons, albedo neutrons, and proton-induced radioactivation, respectively. Monte Carlo simulations of the in-orbit background of the HXI reproduce the observed background spectrum of each layer well, thereby verifying the above hypothesis quantitatively. In addition, we suggest the inclusion of an electron shield to reduce the background.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا