Characterization of a CLYC detector for underground experiments

59   0   0.0 ( 0 )
 Added by Trino Martinez
 Publication date 2017
  fields Physics
and research's language is English
 Authors T. Martinez




Ask ChatGPT about the research

Large size detectors based on Cs2LiYCl6:Ce (CLYC) are capable of performing a combined $gamma$-ray and neutron spectrometry and constitute a promising technology for a wide range of applications in nuclear and high energy physics. Due to their novelty, the comprehensive characterization of the performance of individual CLYC detectors is of great importance for determining their range of applicability. In this work we report on a wide series measurements performed with a commercial 2x2 CLYC crystal. Good energy and timing resolution values of 4.7% (@ 662 keV) and 1340 ps (FWHM), respectively, were achieved, and a neutron/$gamma$ separation figure of merit value of 4.2 was obtained. A dedicated measurement for investigating the intrinsic background of the detector was performed at the Laboratorio Subterraneo de Canfranc (Spain). It evidenced a sizeable contamination in the detector materials which poses limits in the use of CLYC in low background experiments. In addition, detailed Monte Carlo simulations with the GEANT4 toolkit were performed for modeling the response function of the CLYC detector to gamma-rays. An excellent agreement with the experimental data has been achieved.



rate research

Read More

93 - P. P. Povinec 2015
A reference material designed for the determination of natural radionuclides in solid samples (glass pellets) is described and the results of certification are presented. The material has been certified for 7 natural radionuclides (40K, 226Ra, 228Ra, 228Th, 232Th, 235U and 238U). An information value is given for 210Pb. Radon (222Rn) emanation experiments showed results comparable within participating laboratories, however, the number of data and precision was too low to carry out a certification process. The reference material may be used for quality management of analytical laboratories engaged in the high-sensitive analysis of radionuclides in the construction materials of detectors placed in ultra low background underground laboratories.
This article reports the characterization of two High Purity Germanium detectors performed by extracting and comparing their efficiencies using experimental data and Monte Carlo simulations. The efficiencies were calculated for pointlike $gamma$-ray sources as well as for extended calibration sources. Characteristics of the detectors such as energy linearity, energy resolution, and full energy peak efficiencies are reported from measurements performed on surface laboratories. The detectors will be deployed in a $gamma$-ray assay facility that will be located in the first underground laboratory in Mexico, Laboratorio Subterraneo de Mineral del Chico (LABChico), in the Comarca Minera UNESCO Global Geopark
We present a scintillator based detector able to measure both spatial and energy information at High repetition rate (HRR) with a relatively simple design. It has been built at the Center of Pulsed Laser (CLPU) in Salamanca and tested in the proton accelerator at the Centro de Micro-Analisis de Materiales (CMAM) in Madrid. The detector has been demonstrated to work in HRR mode by reproducing the performance of the radiochromic film detector. It represents a new class of on-line detectors for Laser-plasma physics experiments in the new emerging High Power and HRR laser systems.
78 - J. Marton , A. Pichler , H. Shi 2018
The VIP2 experiment tests the Pauli Exclusion Principle with high sensitivity, by searching for Pauli-forbidden atomic transitions from the 2p to the 1s shell in copper at about 8keV. The transition energy of Pauli-forbidden K X-rays is shifted by about 300 eV with respect to the normal allowed K line. This energy difference can be resolved using Silicon Drift Detectors. The data for this experiment is taken in the Gran Sasso underground laboratory (LNGS), which provides shielding from cosmic radiation. An overview of the detection system of the VIP2 experiment will be given. This includes the Silicon Drift Detectors used as X-ray detectors which provide an energy resolution of around 150 eV at 6 keV and timing information for active shielding. Furthermore, the low maintenance requirement makes them excellent X-ray detectors for the use in an underground laboratory. The VIP2 setup will be discussed which consists of a high current target system and a passive as well as an active shielding system using plastic scintillators read out by Silicon Photomultipliers.
Silicon Drift Detectors, widely employed in high-resolution and high-rate X-ray applications, are considered here with interest also for electron detection. The accurate measurement of the tritium beta decay is the core of the TRISTAN (TRitium Investigation on STerile to Active Neutrino mixing) project. This work presents the characterization of a single-pixel SDD detector with a mono-energetic electron beam obtained from a Scanning Electron Microscope. The suitability of the SDD to detect electrons, in the energy range spanning from few keV to tens of keV, is demonstrated. Experimental measurements reveal a strong effect of the detectors entrance window structure on the observed energy response. A detailed detector model is therefore necessary to reconstruct the spectrum of an unknown beta-decay source.