No Arabic abstract
For the first time, a direct detection BOTDR is demonstrated for distributed dynamic strain sensing incorporating double-edge technique, time-division multiplexing technique and upconversion technique. The double edges are realized by using the transmission curve and reflection curve of an all-fiber Fabry-Perot interferometer (FPI). Benefiting from the low loss of the fiber at, the time-division multiplexing technique is performed to realize the double-edge technique by using only a single-channel FPI and only one piece of a detector. In order to detect the weak spontaneous Brillouin backscattering signal efficiently, a fiber-coupled upconversion detector is adopted to upconvert the backscattering signal at 1548.1 nm to 863 nm, which is detected by a Si-APD finally. In the experiment, dynamic strain disturbance up to 1.9m{epsilon} over 1.5 km of polarization maintaining fiber is detected at a sampling rate of 30 Hz. An accuracy of 30{mu}{epsilon} and spatial resolution of 0.6 m is realized.
We present Doppler-corrected position and velocity measurement with a fiber-coupled COFDR system based on the FMCW radar principle for high precision localization applications. A high measurement accuracy and the ability to track targets are demonstrated.
A new imaging technique for $alpha$-particles using a fast optical camera focused on a thin scintillator is presented. As $alpha$-particles interact in a thin layer of LYSO fast scintillator, they produce a localized flash of light. The light is collected with a lens to an intensified optical camera, Tpx3Cam, with single photon sensitivity and excellent spatial & temporal resolutions. The interactions of photons with the camera is reconstructed by means of a custom algorithm, capable of discriminating single photons using time and spatial information.
A new double time-of-flight (dTOF) neutron spectroscopy technique has been developed for pulsed broad spectrum sources with a duty cycle that results in frame overlap, where fast neutrons from a given pulse overtake slower neutrons from previous pulses. Using a tunable beam at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory, neutrons were produced via thick-target breakup of 16 MeV deuterons on a beryllium target in the cyclotron vault. The breakup spectral shape was deduced from a dTOF measurement using an array of EJ-309 organic liquid scintillators. Simulation of the neutron detection efficiency of the scintillator array was performed using both GEANT4 and MCNP6. The efficiency-corrected spectral shape was normalized using a foil activation technique to obtain the energy-dependent flux of the neutron beam at zero degrees with respect to the incoming deuteron beam. The dTOF neutron spectrum was compared to spectra obtained using HEPROW and GRAVEL pulse height spectrum unfolding techniques. While the unfolding and dTOF results exhibit some discrepancies in shape, the integrated flux values agree within two standard deviations. This method obviates neutron time-of-flight spectroscopy challenges posed by pulsed beams with frame overlap and opens new opportunities for pulsed white neutron source facilities.
We present a robust imaging method based on time-correspondence imaging and normalized ghost imaging (GI) that sets two thresholds to select the reference frame exposures for image reconstruction. This double-threshold time-correspondence imaging protocol always gives better quality and signal-to-noise ratio than previous GI schemes, and is insensitive to surrounding noise. Moreover, only simple add and minus operations are required while less data storage space and computing time are consumed, thus faster imaging speeds are attainable. The protocol offers a general approach applicable to all GI techniques, and marks a further step forward towards real-time practical applications of correlation imaging.
Cascades from high-energy particles produce a brief current and associated magnetic fields. Even sub-nanosecond duration magnetic fields can be detected with a relatively low bandwidth system by latching image currents on a capacitor. At accelerators, this technique is employed routinely by beam-current monitors, which work for pulses even as fast as femtoseconds. We discuss scaling up these instruments in size, to 100 meters and beyond, to serve as a new kind of ground- and space-based high-energy particle detector which can instrument large areas relatively inexpensively. This new technique may be used to detect and/or veto ultra-high energy cosmic-ray showers above 100 PeV. It may also be applied to searches for hypothetical highly charged particles. In addition, these detectors may serve to search for extremely short magnetic field pulses of any origin, faster than other detectors by orders of magnitude.