In vitro cell proliferation assays are widely used in pharmacology, molecular biology, and drug discovery. Using theoretical modeling and experimentation, we show that current antiproliferative drug effect metrics suffer from time-dependent bias, leading to inaccurate assessments of parameters such as drug potency and efficacy. We propose the drug-induced proliferation (DIP) rate, the slope of the line on a plot of cell population doublings versus time, as an alternative, time-independent metric.
The phenomena of stochasticity in biochemical processes have been intriguing life scientists for the past few decades. We now know that living cells take advantage of stochasticity in some cases and counteract stochastic effects in others. The source of intrinsic stochasticity in biomolecular systems are random timings of individual reactions, which cumulatively drive the variability in outputs of such systems. Despite the acknowledged relevance of stochasticity in the functioning of living cells no rigorous method have been proposed to precisely identify sources of variability. In this paper we propose a novel methodology that allows us to calculate contributions of individual reactions into the variability of a systems output. We demonstrate that some reactions have dramatically different effects on noise than others. Surprisingly, in the class of open conversion systems that serve as an approximate model of signal transduction, the degradation of an output contributes half of the total noise. We also demonstrate the importance of degradation in other relevant systems and propose a degradation feedback control mechanism that has the capability of an effective noise suppression. Application of our method to some well studied biochemical systems such as: gene expression, Michaelis-Menten enzyme kinetics, and the p53 system indicates that our methodology reveals an unprecedented insight into the origins of variability in biochemical systems. For many systems an analytical decomposition is not available; therefore the method has been implemented as a Matlab package and is available from the authors upon request.
Although reproducibility is a core tenet of the scientific method, it remains challenging to reproduce many results. Surprisingly, this also holds true for computational results in domains such as systems biology where there have been extensive standardization efforts. For example, Tiwari et al. recently found that they could only repeat 50% of published simulation results in systems biology. Toward improving the reproducibility of computational systems research, we identified several resources that investigators can leverage to make their research more accessible, executable, and comprehensible by others. In particular, we identified several domain standards and curation services, as well as powerful approaches pioneered by the software engineering industry that we believe many investigators could adopt. Together, we believe these approaches could substantially enhance the reproducibility of systems biology research. In turn, we believe enhanced reproducibility would accelerate the development of more sophisticated models that could inform precision medicine and synthetic biology.
The study and applications of ferroelectric materials in the biomedical and biotechnological fields is a novel and very promising scientific area that spans roughly one decade. However, some groups have already provided experimental proof of very interesting biological modulation when living systems are exposed to different ferroelectrics and excitation mechanisms. These materials should offer several advantages in the field of bioelectricity, such as no need of an external electric power source or circuits, scalable size of the electroactive regions, flexible and reconfigurable virtual electrodes, or fully proved biocompatibility. In this focused review we provide the underlying physics of ferroelectric activity and a recount of the research reports already published, along with some tentative biophysical mechanisms that can explain the observed results. More specifically, we focused on the biological actions of domain ferroelectrics, and ferroelectrics excited by the bulk photovoltaic effect or the pyroelectric effect. It is our goal to provide a comprehensive account of the published material so far, and to set the stage for a vigorous expansion of the field, with envisioned applications that span from cell biology and signaling to cell and tissue regeneration, antitumoral action, or cell bioengineering to name a few.
Fluorescence Lifetime Imaging Microscopy (FLIM) using multiphoton excitation techniques is now finding an important place in quantitative imaging of protein-protein interactions and intracellular physiology. We review here the recent developments in multiphoton FLIM methods and also present a description of a novel multiphoton FLIM system using a streak camera that was developed in our laboratory. We provide an example of a typical application of the system in which we measure the fluorescence resonance energy transfer between a donor/acceptor pair of fluorescent proteins within a cellular specimen.
Summary: More sophisticated models are needed to address problems in bioscience, synthetic biology, and precision medicine. To help facilitate the collaboration needed for such models, the community developed the Simulation Experiment Description Markup Language (SED-ML), a common format for describing simulations. However, the utility of SED-ML has been hampered by limited support for SED-ML among modeling software tools and by different interpretations of SED-ML among the tools that support the format. To help modelers debug their simulations and to push the community to use SED-ML consistently, we developed a tool for validating SED-ML files. We have used the validator to correct the official SED-ML example files. We plan to use the validator to correct the files in the BioModels database so that they can be simulated. We anticipate that the validator will be a valuable tool for developing more predictive simulations and that the validator will help increase the adoption and interoperability of SED-ML. Availability: The validator is freely available as a webform, HTTP API, command-line program, and Python package at https://run.biosimulations.org/utils/validate and https://pypi.org/project/biosimulators-utils. The validator is also embedded into interfaces to 11 simulation tools. The source code is openly available as described in the Supplementary data. Contact: