Do you want to publish a course? Click here

Neutron reflectometry on highly absorbing films and its application to 10B4C-based neutron detectors

68   0   0.0 ( 0 )
 Publication date 2015
  fields Physics
and research's language is English




Ask ChatGPT about the research

Neutron reflectometry is a powerful tool used for studies of surfaces and interfaces. In general the absorption in the typical studied materials can be neglected and this technique is limited to the measurement of the reflectivity only. In the case of strongly absorbing nuclei the number of neutrons is not conserved and the absorption can be directly measured by using the neutron-induced fluorescence technique which exploits the prompt particle emission of absorbing isotopes. This technique is emerging from soft matter and biology where highly absorbing nuclei, generally in very small quantities, are used as a label for buried layers. Nowadays the importance of highly absorbing layers is rapidly increasing, partially because of their application in neutron detection; a field that has become more and more active also due to the 3He-shortage. In this manuscript we extend the neutron-induced fluorescence technique to the study of thick layers of highly absorbing materials; in particular 10B4C. The theory of neutron reflectometry is a commonly studied topic, however the subtle relationship between the reflection and the absorption of neutrons is not widely known, in particular when a strong absorption is present. The theory for a general stack of absorbing layers has been developed and compared to measurements. This new technique has potential as a tool for characterization of highly absorbing layers. We also report on the requirements that a 10B4C layer must fulfill in order to be employed as a converter in neutron detection.



rate research

Read More

104 - Giacomo Mauri 2019
Neutron scattering techniques offer a unique combination of structural and the dynamic information of atomic and molecular systems over a wide range of distances and times. The increasing complexity in science investigations driven by technological advances is reflected in the studies of neutron scattering science, which enforces a diversification and an improvement of experimental tools, from the instrument design to the detector performance. It calls as well for more advanced data analysis and modelling. The improvements in resolution, count rate and signal-to-background ratio, achievable with the new instrumentations, also drive the research of alternative technologies to replace the 3He-based detector technology unable to fulfil the requirement of increasing performance. Two solution have been studied: a boron-10-based gaseous detector, the Multi-Blade and a solid-state Si-Gd detector. Both solution are suitable alternatives for neutron detection, able to meet the demands of high performance. It has been shown not only the technical characteristic of the devices, but how the science can profit from the better performance of these new detector technologies in real experimental condition.
We have determined the depth-resolved magnetization structures of a series of highly ordered Sr$_{2}$CrReO$_{6}$ (SCRO) ferrimagnetic epitaxial films via combined studies of x-ray reflectometry, polarized neutron reflectometry and SQUID magnetometry. The SCRO films deposited directly on (LaAlO$_3$)$_{0.3}$(Sr$_2$AlTaO$_6$)$_{0.7}$ or SrTiO$_{3}$ substrates show reduced magnetization of similar width near the interfaces with the substrates, despite having different degrees of strain. When the SCRO film is deposited on a Sr$_{2}$CrNbO$_{6}$ (SCNO) double perovskite buffer layer, the width the interfacial region with reduced magnetization is reduced, agreeing with an improved Cr/Re ordering. However, the relative reduction of the magnetization averaged over the interfacial regions are comparable among the three samples. Interestingly, we found that the magnetization suppression region is wider than the Cr/Re antisite disorder region at the interface between SCRO and SCNO.
Polarized neutron reflectometry (PNR) is a powerful technique to interrogate the structures of multilayered magnetic materials with depth sensitivity and nanometer resolution. However, reflectometry profiles often inhabit a complicated objective function landscape using traditional fitting methods, posing a significant challenge to parameter retrieval. In this work, we develop a data-driven framework to recover the sample parameters from PNR data with minimal user intervention. We train a variational autoencoder to map reflectometry profiles with moderate experimental noise to an interpretable, low-dimensional space from which sample parameters can be extracted with high resolution. We apply our method to recover the scattering length density profiles of the topological insulator (TI)-ferromagnetic insulator heterostructure Bi$_2$Se$_3$/EuS, exhibiting proximity magnetism, in good agreement with the results of conventional fitting. We further analyze a more challenging PNR profile of the TI-antiferromagnet heterostructure (Bi,Sb)$_2$Te$_3$/Cr$_2$O$_3$, and identify possible interfacial proximity magnetism in this material. We anticipate the framework developed here can be applied to resolve hidden interfacial phenomena in a broad range of layered systems.
72 - Z. Liu , H. Lane , C. D. Frost 2021
An instrument and software algorithm is described for the purpose of characterization of large single crystals at the Alignment Facility (ALF) of the ISIS spallation neutron source. We describe a method for both characterizing the quality of the sample and also aligning it in a particular scattering plane. We present a software package written for this instrument and demonstrate its utility by way of an example of the structural characterization of large singles crystals of Pb(Mg$_{1/3}$Nb$_{2/3}$)O$_{3}$. We suggest extensions and modifications of characterization instruments for future improved beamlines. It is hoped that this software will be used by the neutron user community for pre characterizing large single crystals for spectroscopy experiments and that future facilities will include such a facility as part of the spectroscopy suite at spallation neutron sources.
104 - F Marsili , D Bitauld , A Gaggero 2009
The Parallel Nanowire Detector (PND) is a photon number resolving (PNR) detector which uses spatial multiplexing on a subwavelength scale to provide a single electrical output proportional to the photon number. The basic structure of the PND is the parallel connection of several NbN superconducting nanowires (100 nm-wide, few nm-thick), folded in a meander pattern. PNDs were fabricated on 3-4 nm thick NbN films grown on MgO (TS=400C) substrates by reactive magnetron sputtering in an Ar/N2 gas mixture. The device performance was characterized in terms of speed and sensitivity. PNDs showed a counting rate of 80 MHz and a pulse duration as low as 660ps full width at half maximum (FWHM). Building the histograms of the photoresponse peak, no multiplication noise buildup is observable. Electrical and optical equivalent models of the device were developed in order to study its working principle, define design guidelines, and develop an algorithm to estimate the photon number statistics of an unknown light. In particular, the modeling provides novel insight of the physical limit to the detection efficiency and to the reset time of these detectors. The PND significantly outperforms existing PNR detectors in terms of simplicity, sensitivity, speed, and multiplication noise.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا