High-fidelity qubit measurement with a microwave photon counter

248   0   0.0 ( 0 )
 Added by Luke Govia
 Publication date 2015
  fields Physics
and research's language is English




Ask ChatGPT about the research

High-fidelity, efficient quantum nondemolition readout of quantum bits is integral to the goal of quantum computation. As superconducting circuits approach the requirements of scalable, universal fault tolerance, qubit readout must also meet the demand of simplicity to scale with growing system size. Here we propose a fast, high-fidelity, scalable measurement scheme based on the state-selective ring-up of a cavity followed by photodetection with the recently introduced Josephson photomultiplier (JPM), a current-biased Josephson junction. This scheme maps qubit state information to the binary digital output of the JPM, circumventing the need for room-temperature heterodyne detection and offering the possibility of a cryogenic interface to superconducting digital control circuitry. Numerics show that measurement contrast in excess of 95% is achievable in a measurement time of 140 ns. We discuss perspectives to scale this scheme to enable readout of multiple qubit channels with a single JPM.



rate research

Read More

Quantum emitters respond to resonant illumination by radiating electromagnetic fields. A component of these fields is phase-coherent with the driving tone, while another one is incoherent, consisting of spontaneously emitted photons and forming the fluorescence signal. Atoms and molecules are routinely detected by their fluorescence at optical frequencies, with important applications in quantum technology and microscopy. Spins, on the other hand, are usually detected by {their coherent response} at radio- or microwave frequencies, either in continuous-wave or pulsed magnetic resonance. Indeed, fluorescence detection of spins is hampered {by their low spontaneous emission rate} and by the lack of single-photon detectors in this frequency range. Here, using superconducting quantum devices, we demonstrate the detection of a small ensemble of donor spins in silicon by their fluorescence at microwave frequency and millikelvin temperatures. We enhance the spin radiative decay rate by coupling them to a high-quality-factor and small-mode-volume superconducting resonator, and we connect the device output to a newly-developed microwave single-photon counter based on a superconducting qubit. We discuss the potential of fluorescence detection as a novel method for magnetic resonance spectroscopy of small numbers of spins.
Parity measurement is a central tool to many quantum information processing tasks. In this Letter, we propose a method to directly measure two- and four-qubit parity with low overhead in hard- and software, while remaining robust to experimental imperfections. Our scheme relies on dispersive qubit-cavity coupling and photon counting that is sensitive only to intensity; both ingredients are widely realized in many different quantum computing modalities. For a leading technology in quantum computing, superconducting integrated circuits, we analyze the measurement contrast and the back action of the scheme and show that this measurement comes close enough to an ideal parity measurement to be applicable to quantum error correction.
The act of observing a quantum object fundamentally perturbs its state, resulting in a random walk toward an eigenstate of the measurement operator. Ideally, the measurement is responsible for all dephasing of the quantum state. In practice, imperfections in the measurement apparatus limit or corrupt the flow of information required for quantum feedback protocols, an effect quantified by the measurement efficiency. Here we demonstrate the efficient measurement of a superconducting qubit using a nonreciprocal parametric amplifier to directly monitor the microwave field of a readout cavity. By mitigating the losses between the cavity and the amplifier we achieve a measurement efficiency of $72%$. The directionality of the amplifier protects the readout cavity and qubit from excess backaction caused by amplified vacuum fluctuations. In addition to providing tools for further improving the fidelity of strong projective measurement, this work creates a testbed for the experimental study of ideal weak measurements, and it opens the way towards quantum feedback protocols based on weak measurement such as state stabilization or error correction.
Highly state-selective, weakly dissipative population transfer is used to irreversibly move the population of one ground state qubit level of an atomic ion to an effectively stable excited manifold with high fidelity. Subsequent laser interrogation accurately distinguishes these electronic manifolds, and we demonstrate a total qubit state preparation and measurement (SPAM) inaccuracy $epsilon_mathrm{SPAM} < 1.7 times 10^{-4}$ ($-38 mbox{ dB}$), limited by imperfect population transfer between qubit eigenstates. We show experimentally that full transfer would yield an inaccuracy less than $8.0 times 10^{-5}$ ($-41 mbox{ dB}$). The high precision of this method revealed a rare ($approx 10^{-4}$) magnetic dipole decay induced error that we demonstrate can be corrected by driving an additional transition. Since this technique allows fluorescence collection for effectively unlimited periods, high fidelity qubit SPAM is achievable even with limited optical access and low quantum efficiency.
Single-photon sources are of great interest because they are key elements in different promising applications of quantum technologies. Here we demonstrate a highly efficient tunable on-demand microwave single-photon source based on a transmon qubit with the intrinsic emission efficiency above 98$%$. The high efficiency ensures a negligible pure dephasing rate and the necessary condition for generation of indistinguishable photons. We provide an extended discussion and analysis of the efficiency of the photon generation. To further experimentally confirm the single-photon property of the source, correlation functions of the emission field are also measured using linear detectors with a GPU-enhanced signal processing technique. Our results experimentally demonstrate that frequency tunability and negligible pure dephasing rate can be achieved simultaneously and show that such a tunable single-photon source can be good for various practical applications in quantum communication, simulations and information processing in the microwave regime.