Do you want to publish a course? Click here

On-sky low order non-common path correction of the GPI Calibration Unit

133   0   0.0 ( 0 )
 Added by Markus Hartung PhD
 Publication date 2014
  fields Physics
and research's language is English




Ask ChatGPT about the research

The Gemini Planet Imager (GPI) entered on-sky commissioning phase, and had its First Light at the Gemini South telescope in November 2013. Meanwhile, the fast loops for atmospheric correction of the Extreme Adaptive Optics (XAO) system have been closed on many dozen stars at different magnitudes (I=4-8), elevation angles and a variety of seeing conditions, and a stable loop performance was achieved from the beginning. Ultimate contrast performance requires a very low residual wavefront error (design goal 60 nm RMS), and optimization of the planet finding instrument on different ends has just begun to deepen and widen its dark hole region. Laboratory raw contrast benchmarks are in the order of 10^-6 or smaller. In the telescope environment and in standard operations new challenges are faced (changing gravity, temperature, vibrations) that are tackled by a variety of techniques such as Kalman filtering, open-loop models to keep alignment to within 5 mas, speckle nulling, and a calibration unit (CAL). The CAL unit was especially designed by the Jet Propulsion Laboratory to control slowly varying wavefront errors at the focal plane of the apodized Lyot coronagraph by the means of two wavefront sensors: 1) a 7x7 low order Shack-Hartmann SH wavefront sensor (LOWFS), and 2) a special Mach-Zehnder interferometer for mid-order spatial frequencies (HOWFS) - atypical in that the beam is split in the focal plane via a pinhole but recombined in the pupil plane with a beamsplitter. The original design goal aimed for sensing and correcting on a level of a few nm which is extremely challenging in a telescope environment. This paper focuses on non-common path low order wavefront correction as achieved through the CAL unit on sky. We will present the obtained results as well as explain challenges that we are facing.



rate research

Read More

128 - A. Vigan , M. NDiaye , K. Dohlen 2018
Circumstellar environments are now routinely observed by dedicated high-contrast imagers on large, ground-based observatories. These facilities combine extreme adaptive optics and coronagraphy to achieve unprecedented sensitivities for exoplanet detection and spectral characterization. However, non-common path aberrations (NCPA) in these coronagraphic systems represent a critical limitation for the detection of giant planets with a contrast lower than a few $10^{-6}$ at very small separations ($<$0.3$^{primeprime}$) from their host star. In 2013 we proposed ZELDA, a Zernike wavefront sensor to measure these residual quasi-static phase aberrations and a prototype was installed in SPHERE, the exoplanet imager for the VLT. In 2016, we demonstrated the ability of our sensor to provide a nanometric calibration and compensation for these aberrations on an internal source in the instrument, resulting in a contrast gain of 10 at 0.2$^{primeprime}$ in coronagraphic images. However, initial on-sky tests in 2017 did not show a tangible gain in contrast when calibrating the NCPA internally and then applying the correction on sky. In this communication, we present recent on-sky measurements to demonstrate the potential of our sensor for the NCPA compensation during observations and quantify the contrast gain in coronagraphic data.
It is by now well known that pyramid based wavefront sensors, once in closed loop, have the capability to improve more and more the gain as the reference natural star image size is getting smaller on the pyramid pin. Especially in extreme adaptive optics applications, in order to correct the non-common path aberrations between the scientific and sensing channel, it is common use to inject a certain amount of offset wavefront deformation into the DM(s), departing at the same time the pyramid from the optimal working condition. In this paper we elaborate on the possibility to correct the low order non-common path aberrations at the pyramid wavefront sensor level by means of an adaptive refractive lens placed on the optical path before the pyramid itself, allowing the mitigation of the gain loss.
171 - N. Blind , F. Eisenhauer , M. Haug 2014
We present in this paper the design and characterisation of a new sub-system of the VLTI 2nd generation instrument GRAVITY: the Calibration Unit. The Calibration Unit provides all functions to test and calibrate the beam combiner instrument: it creates two artificial stars on four beams, and dispose of four delay lines with an internal metrology. It also includes artificial stars for the tip-tilt and pupil guiding systems, as well as four metrology pick-up diodes, for tests and calibration of the corresponding sub-systems. The calibration unit also hosts the reference targets to align GRAVITY to the VLTI, and the safety shutters to avoid the metrology light to propagate in the VLTI-lab. We present the results of the characterisation and validtion of these differrent sub-units.
This paper deals with the calibration of the analogue chains of a Square Kilometre Array (SKA) phased aperture array station, using embedded element patterns (one per antenna in the array, thus accounting for the full effects of mutual coupling) or average element patterns to generate model visibilities. The array is composed of 256 log-periodic dipole array antennas. A simulator capable of generating such per-baseline model visibility correlation matrices was implemented, which allowed for a direct comparison of calibration results using StEFCal (Statistically Efficient and Fast Calibration) with both pattern types. Calibrating the array with StEFCal using simulator-generated model visibilities was successful and thus constitutes a possible routine for calibration of an SKA phase aperture array station. In addition, results indicate that there was no significant advantage in calibrating with embedded element patterns, with StEFCal successfully retrieving similar per-element coefficients with model visibilities generated with either pattern type. This can be of significant importance for mitigating computational costs for calibration, particularly for the consideration of real-time calibration strategies. Data from the AAVS-1 (Aperture Array Verification System 1) prototype station in Western Australia was used for demonstration purposes.
SOXS is a new spectrograph for the New Technology Telescope (NTT), optimized for transient and variable objects, covering a wide wavelength range from 350 to 2000 nm. SOXS is equipped with a calibration unit that will be used to remove the instrument signatures and to provide wavelength calibration to the data. The calibration unit will employ seven calibration lamps: a quartz-tungsten-halogen and a deuterium lamp for the flat-field correction, a ThAr lamp and four pencil-style rare-gas lamps for the wavelength calibration. The light from the calibration lamps is injected into the spectrograph mimicking the f/11 input beam of the NTT, by using an integrating sphere and a custom doublet. The oversized illumination patch covers the length of the spectrograph slit homogeneously, with $< 1%$ variation. The optics also supports the second mode of the unit, the star-simulator mode that emulates a point source by utilizing a pinhole mask. Switching between the direct illumination and pinhole modes is performed by a linear stage. A safety interlock switches off the main power when the lamp box cover is removed, preventing accidental UV exposure to the service personnel. All power supplies and control modules are located in an electronic rack at a distance from the telescope platform. In this presentation we describe the optical, mechanical, and electrical designs of the SOXS calibration unit, and report the status of development in which the unit is currently in the test and verification stage.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا